Sleep thermal comfort and the energy saving potential due to reduced indoor operative temperature during sleep

2013 ◽  
Vol 59 ◽  
pp. 91-98 ◽  
Author(s):  
Chris Leung ◽  
Hua Ge
Author(s):  
Lingjiang Huang ◽  
Jian Kang

AbstractThe solar incidence on an indoor environment and its occupants has significant impacts on indoor thermal comfort. It can bring favorable passive solar heating and can result in undesired overheating (even in winter). This problem becomes more critical for high altitudes with high intensity of solar irradiance, while received limited attention. In this study, we explored the specific overheating and rising thermal discomfort in winter in Lhasa as a typical location of a cold climate at high altitudes. First, we evaluated the thermal comfort incorporating solar radiation effect in winter by field measurements. Subsequently, we investigated local occupant adaptive responses (considering the impact of direct solar irradiance). This was followed by a simulation study of assessment of annual based thermal comfort and the effect on energy-saving potential by current solar adjustment. Finally, we discussed winter shading design for high altitudes for both solar shading and passive solar use at high altitudes, and evaluated thermal mass shading with solar louvers in terms of indoor environment control. The results reveal that considerable indoor overheating occurs during the whole winter season instead of summer in Lhasa, with over two-thirds of daytime beyond the comfort range. Further, various adaptive behaviors are adopted by occupants in response to overheating due to the solar radiation. Moreover, it is found that the energy-saving potential might be overestimated by 1.9 times with current window to wall ratio requirements in local design standards and building codes due to the thermal adaption by drawing curtains. The developed thermal mass shading is efficient in achieving an improved indoor thermal environment by reducing overheating time to an average of 62.2% during the winter and a corresponding increase of comfort time.


2019 ◽  
Vol 202 ◽  
pp. 109390 ◽  
Author(s):  
Shenglan Jing ◽  
Yonggang Lei ◽  
Hongjian Wang ◽  
Chongfang Song ◽  
Xufeng Yan

Buildings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 248
Author(s):  
Ruey-Lung Hwang ◽  
Bi-Lian Chen ◽  
Wei-An Chen

Strategies to reduce energy consumption are presently experiencing vigorous development. Phase change materials (PCMs) are novel materials that can reduce indoor temperatures via the change in material phase. Regarding the situation in Taiwan, there is no practical utilization of PCMs in school buildings at present, especially in combination with rooftops. In this paper, we discuss the feasibility and utilization potential of installing PCMs in the rooftops of school buildings. School buildings located in northern and southern Taiwan (Taipei and Kaohsiung) were selected to analyze the energy-saving potential and optimization of indoor thermal comfort by installing PCMs with different properties in rooftops over two time periods, including the air conditioning (AC) and natural ventilation (NV) seasons. Based on the simulation results, the feasible patterns of PCM simultaneity are found to be appropriate for improved indoor comfort and energy saving during the different seasons. Specifically, the efficient phase change temperature (PCT) for different PCM thicknesses is clarified to be 29 °C. The economic thickness of PCM was clarified to be 20 mm for Taipei and Kaohsiung. Through the recommendations proposed in this study, it is expected that the PCMs may be efficiently implemented in school buildings to realize the goal of energy conservation and improve thermal comfort.


Sign in / Sign up

Export Citation Format

Share Document