The Energy Saving Potential and the Associated Thermal Comfort of Displacement Ventilation Systems Assisted by Personalised Ventilation

2012 ◽  
Vol 22 (3) ◽  
pp. 508-519 ◽  
Author(s):  
Alain Makhoul ◽  
Kamel Ghali ◽  
Nesreen Ghaddar
Author(s):  
Lingjiang Huang ◽  
Jian Kang

AbstractThe solar incidence on an indoor environment and its occupants has significant impacts on indoor thermal comfort. It can bring favorable passive solar heating and can result in undesired overheating (even in winter). This problem becomes more critical for high altitudes with high intensity of solar irradiance, while received limited attention. In this study, we explored the specific overheating and rising thermal discomfort in winter in Lhasa as a typical location of a cold climate at high altitudes. First, we evaluated the thermal comfort incorporating solar radiation effect in winter by field measurements. Subsequently, we investigated local occupant adaptive responses (considering the impact of direct solar irradiance). This was followed by a simulation study of assessment of annual based thermal comfort and the effect on energy-saving potential by current solar adjustment. Finally, we discussed winter shading design for high altitudes for both solar shading and passive solar use at high altitudes, and evaluated thermal mass shading with solar louvers in terms of indoor environment control. The results reveal that considerable indoor overheating occurs during the whole winter season instead of summer in Lhasa, with over two-thirds of daytime beyond the comfort range. Further, various adaptive behaviors are adopted by occupants in response to overheating due to the solar radiation. Moreover, it is found that the energy-saving potential might be overestimated by 1.9 times with current window to wall ratio requirements in local design standards and building codes due to the thermal adaption by drawing curtains. The developed thermal mass shading is efficient in achieving an improved indoor thermal environment by reducing overheating time to an average of 62.2% during the winter and a corresponding increase of comfort time.


2017 ◽  
Vol 111 ◽  
pp. 256-264 ◽  
Author(s):  
Julia Maier ◽  
Claudia Marggraf-Micheel ◽  
Tobias Dehne ◽  
Johannes Bosbach

2016 ◽  
Vol 824 ◽  
pp. 625-632
Author(s):  
Mária Budiaková

The paper is oriented on the analysis of the ventilation systems in schoolrooms. Correct and sufficient ventilation of schoolrooms is very important because students and pupils spend in the schoolrooms the majority of their time in school. In our schools the ventilation is incorrect and insufficient. The biggest problem is winter period when the ventilation is provided only by opening the doors to corridor. This way, there is insufficient intake of oxygen, which causes distractibility and feeling of tiredness of pupils. In current schoolrooms we can use only natural ventilation and thus the schoolrooms have to be ventilated using windows. Therefore this research was focused on the comparison and the analysis of different systems of natural ventilation in schoolrooms. The experimental measurements were carried out in schoolroom, where the parameters of thermal comfort were measured in the different systems of natural ventilation with device Testo 480 which was connected to computer. Gained values of air temperature, air velocity and index PMV are presented in graphs. On the base of analysis of measured values were evaluated the systems of natural ventilation for schoolrooms. In the future, the mechanical ventilation in schoolrooms can be assumed, therefore the recommendation on modern energy saving system of mechanical ventilation is in the end of this paper.


2019 ◽  
Vol 202 ◽  
pp. 109390 ◽  
Author(s):  
Shenglan Jing ◽  
Yonggang Lei ◽  
Hongjian Wang ◽  
Chongfang Song ◽  
Xufeng Yan