scholarly journals Experimental measurement and numerical simulation of the thermal performance of a double glazing system with an interstitial Venetian blind

2016 ◽  
Vol 103 ◽  
pp. 111-122 ◽  
Author(s):  
Yanyi Sun ◽  
Yupeng Wu ◽  
Robin Wilson ◽  
Sixu Lu
2015 ◽  
Vol 37 (2) ◽  
pp. 220-231 ◽  
Author(s):  
Mohammad Hasan Shojaeefard ◽  
Javad Zare ◽  
Mojtaba Tahani

2014 ◽  
Vol 6 ◽  
pp. 853069 ◽  
Author(s):  
Dong Liu ◽  
Ying-ze Wang ◽  
Hyoung-Bum Kim ◽  
Fang-neng Zhu ◽  
Chun-lin Wang

The wavy vortex flow in the plain model was studied by experimental measurement; the preliminary feature of wavy vortex flow was obtained. This flow field in the plain model was also studied by numerical simulation. The reliability of numerical simulation was verified by comparing with the experimental and numerical simulation results. To study the slit wall effect on the wavy vortex flow regime, another two models with different slit number were considered; the slit number was 6 and 12. By comparing the wavy vortex flow field in different models, the axial fluctuation of Taylor vortices was found to be different, which was increased with the increasing of slit number. The maximum radial velocity from the inner cylinder to the outer one in the 6-slit number was increased by 12.7% compared to that of plain model. From the results of different circumferential position in the same slit model, it can be found that the maximum radial velocity in slit plane is significantly greater than that in other planes. The size of Taylor vortices in different models was also calculated, which was found to be increased in the 6-slit model but was not changed as the slit number increased further.


Solar Energy ◽  
2018 ◽  
Vol 162 ◽  
pp. 533-540 ◽  
Author(s):  
Jingchao Xie ◽  
Wei Wang ◽  
Jiaping Liu ◽  
Song Pan

Designs ◽  
2020 ◽  
Vol 4 (3) ◽  
pp. 34
Author(s):  
Pedro F. Gois ◽  
Ângelo J. Costa e Silva ◽  
João M. P. Q. Delgado ◽  
António C. Azevedo ◽  
Ana S. Guimarães ◽  
...  

This work presents an extensive numerical simulation to analyze the influence of the coating layers on the performance of construction systems, in order to make the constructions projects feasible, not only economically but also technically. Through numerical simulations based on a defined reference model, the present work studied the influence of different layers of floor, roof and internal and external wall systems, on the acoustic, thermal, and luminous performance of buildings in Brazil. The results showed the materials and elements with the greatest influence on: lighting performance are the internal finishes of the environment and the type of glass used in the external windows. On thermal performance, all elements of the roofing system and façades, especially an absence of external cladding and the use of thermal blankets on the roof, have greater influence. The acoustic performance of the façade function on the external windows and acoustic performance of the floor system are mainly influenced by the thickness of the structural element and the use of a ceiling and acoustic blanket; acoustic performance of internal walls is affected by typology of the structured element of the wall and thickness.


Sign in / Sign up

Export Citation Format

Share Document