On the effect of provision of balconies on natural ventilation and thermal comfort in high-rise residential buildings

2017 ◽  
Vol 123 ◽  
pp. 504-516 ◽  
Author(s):  
S. Omrani ◽  
V. Garcia-Hansen ◽  
B.R. Capra ◽  
R. Drogemuller
2011 ◽  
Vol 20 (1) ◽  
pp. 101-111 ◽  
Author(s):  
Baizhan Li ◽  
Wei Yu ◽  
Meng Liu ◽  
Nan Li

Yangtze River Valley is situated within the Hot Summer and Cold Winter zone, and residents in this region of China would require HVAC system to alleviate thermal comfort conditions, although this is tempered by the Design Code (DBJ50-071-2007) for energy efficiency. A 1-year survey of about 200 residential homes was carried out in eight cities covering the breadth of the region. The acceptable temperature range for the residents in this area was 16.3—28.1°C and the thermal neutral temperature was found to be 27.6°C in summers and 17.5°C in winters. People in different area can vary in their adaptability and comfortableness. Therefore, there is a need to investigate the national comfort parameter introduced in the Code for Design of Heating and Ventilation and Air Conditioning (GB50019-2003). The results found that if air-conditioning system was set to 27.5°C instead of 26°C as required by GBJ19-87: Design Standard of Heating and Ventilation and Air Conditioning, a 16.5% saving of energy consumption could be achieved. The findings demonstrated the role of natural ventilation in the expansion of the thermal comfort zone for the residents, especially during the summer seasons. A climatic adaptability model has been established by this study to contribute to the passive climatic design strategies for a better economic and energy efficiency of buildings.


2018 ◽  
Vol 3 (7) ◽  
pp. 357
Author(s):  
Lobna Hassan Ali Hassan Elgheriani ◽  
Parid Wardi ◽  
AbdulBasit Ali Ali Ahmed

Natural ventilation is an effectual passive design approach to create a better indoor thermal condition as well as energy efficiency. The primary goal of building design is providing a healthy and comfortable indoor environment titled as sustainable architecture. Literature suggests that the significant feature that alteration has to take place on for better energy performance is the envelope design. This paper aims to augment the Window to Wall Ratio (WWR), orientation and courtyard corridor size for improving the design of naturally ventilated courtyard high-rise residential buildings. Briefly, the findings indicate that contending with WWR, orientation and courtyard corridor size could increase the potential of improving its natural ventilation and thus, thermal performance.


2020 ◽  
Vol 3 (1) ◽  
pp. p1
Author(s):  
Jad Hammoud ◽  
Elise Abi Rached

The increasing of energy demands has considerably increased the requirements for new and traditional buildings in different climate zones. Unprecedented heat waves have increased climate temperature, in particular, in moderate climate zones such as Lebanon. In Beirut, only the residential sector consumes 50% of total electricity consumption. HVAC (Heating, Ventilation and Air conditioning) systems are used to reach acceptable thermal comfort levels in the new residential buildings. In case of the traditional bourgeoisie houses in Beirut, there are no discussions about the use of HVAC systems to achieve the required thermal comfort level. Thus, to reach an acceptable thermal comfort level, these houses which already contain natural ventilation system shall adapt the modern thermal comfort requirements and thermal comfort strategies and technologies where their architectural features and existing materials condition the available solutions. In order to identify the best options within the possible intervention lines (envelopes, passive strategies, equipment, renewable energy systems), it is necessary to perceive the real performance of this type of houses. In this context, the article presents the results of the study of thermal performance and comfort in a three case studies located in Beirut. Detailed field data records collected are analyzed, with a view to identify the indoor thermal environment with respect to outdoor thermal environment in different seasons. Monitoring also included measurement of hygrothermal parameters and surveys of occupant thermal sensation.


2016 ◽  
Vol 1 (1) ◽  
pp. 348
Author(s):  
Nooriati Taib ◽  
Zalila Ali

One passive approach that can significantly reduce energy usage in high-rise buildings is through the creation of non-air conditioned spaces such as transitional spaces. Optimizing passive design would reduce wastage associated with the building’s energy consumption. The study measures the thermal comfort of three types of transitional spaces (sky court, balcony, and rooftop) in a high-rise office building. Based on the assessment of Physiological Equivalent Temperature (PET), the outcome showed significant differences in PET in all locations in both wet and dry season. The effectiveness of such area can be improved with the contributions of landscape, maximizing natural ventilation and day lighting where possible.© 2016. The Authors. Published for AMER ABRA by e-International Publishing House, Ltd., UK. Peer–review under responsibility of AMER (Association of Malaysian Environment-Behaviour Researchers), ABRA (Association of Behavioural Researchers on Asians) and cE-Bs (Centre for Environment-Behaviour Studies, Faculty of Architecture, Planning & Surveying, Universiti Teknologi MARA, Malaysia.Keywords: Thermal comfort; transitional spaces; high-rise; Physiological Equivalent Temperature


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Hamza Laloui ◽  
Noor Hanita Abdul Majid ◽  
Aliyah Nur Zafirah Sanusi

Purpose This paper aims to investigate the impacts of introducing voids combinations on natural ventilation performance in high-rise residential building living unit. Design/methodology/approach This study was carried out through field measurement and computational fluid dynamics methods. The parameters of the study are void types and sizes, and a wind angle was used to formulate case studies. Findings The results indicate that the provision of a single-sided horizontal void larger by 50% increase the indoor air velocity performance up to 322.37% to 0.471 m/s in the living unit and achieves the required velocity for thermal comfort. Originality/value Passive design features are the most desirable techniques to enhance natural ventilation performance in the high-rise residential apartments for thermal comfort and indoor air quality purposes.


F1000Research ◽  
2021 ◽  
Vol 10 ◽  
pp. 1047
Author(s):  
Nermine Hany ◽  
Hala Alaa

Background: Bioclimatic design is an approach based on local climate which improves thermal qualities and indoor comfort. Buildings follow this process to minimize negative effects on the environment. However, this approach is still not suitable in developed countries. This study aims to investigate Mediterranean local bioclimatic strategies’ impact on thermal comfort efficiency in housing, by examining architectural elements and treatments. Methods: We adopted a descriptive, analytical, and comparative methodology, complemented with a software simulation, within a qualitative and quantitative approach. Investigation and methodological tools were based on technical information including plans, elevations, photos, and documentation. The approach consisted of multiple stages: a literature review interpreting the concept of bioclimatic design, as well as thermal comfort variables and common Mediterranean building features. Moreover, the paper showcases three examples of successful Mediterranean passive houses. Furthermore, the paper presents a case- studyhouse in Alex West, Alexandria, designed in the Mediterranean Revival style. Results: The results showed that the most influencing building features on thermal comfort were the low-pitched roofs and the top chimney, which achieved 12.6% and 5% improvement in the summer and 13% and 6.8% in winter, respectively. The pergola and porch elements barely had an effect when placed on the northern façade. However, on the southern façade, a positive contribution in the summer by 1.4% and 3.4% respectively were reported, but a slight negative impact in winter by 0.5% and 2% respectively. Conclusions:  We examined the impact of common Mediterranean building features , and compared thermal comfort results between case-study houses. Features focusing on passive design for cooling rather than heating, allowing wind flow for maximized natural ventilation, using ventilated pitched roof spaces, using sun shading elements in the proper facades and angles, help passive thermal regulation. The study proposes recommendations for optimizing thermal comfort in residential buildings in Alexandria, Egypt.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Hamza Laloui ◽  
Noor Hanita Abdul Majid ◽  
Aliyah Nur Zafirah Sanusi

PurposeThe paper aims to investigate and evaluate the impacts of the voids combination as a passive design feature on wind-driven ventilation performance in high-rise residential building units. It proposes a series of building models and thereon indoor ventilation performance and outlining why and how these building models designed with architectural design features are important. This study aims to provide a comprehensive understanding of how natural ventilation as a passive cooling strategy in living units of high-rise residential buildings can be applied through improving the provision of the architectural design feature of voids configurations.Design/methodology/approachThe study was carried out through field measurements experiment and the computational fluid dynamics methods. A series of numerical simulations were carried out to calculate the indoor ventilation rate inside the case studies of the generated building models based on various variables such as horizontal voids type, size and wind directions.FindingsThe results indicate that the provision of a single-sided horizontal voids in building models can improve the indoor ventilation rate in units with cross ventilation mode up to 4 times, depending on wind direction and living unit location. The indoor ventilation performance in units located in models with single-sided horizontal voids is 17.54% higher than the units located in models without voids configuration. Furthermore, higher indoor ventilation performance was achieved in the case scenarios located at higher levels compared to the middle and lower levels in both horizontal voids types.Originality/valueThis study explores the application of voids combinations for natural ventilation performance, investigates the numerical simulation results and validates field measurements experiment data using CFD simulation.


Sign in / Sign up

Export Citation Format

Share Document