Real-time measurements of fluorescent aerosol particles in a living laboratory office under variable human occupancy and ventilation conditions

2021 ◽  
pp. 108249
Author(s):  
Satya S. Patra ◽  
Tianren Wu ◽  
Danielle N. Wagner ◽  
Jinglin Jiang ◽  
Brandon E. Boor
2014 ◽  
Vol 14 (15) ◽  
pp. 8055-8069 ◽  
Author(s):  
D. A. Healy ◽  
J. A. Huffman ◽  
D. J. O'Connor ◽  
C. Pöhlker ◽  
U. Pöschl ◽  
...  

Abstract. Primary biological aerosol particles (PBAPs) can contribute significantly to the coarse particle burden in many environments. PBAPs can thus influence climate and precipitation systems as cloud nuclei and can spread disease to humans, animals, and plants. Measurement data and techniques for PBAPs in natural environments at high time- and size resolution are, however, sparse, and so large uncertainties remain in the role that biological particles play in the Earth system. In this study two commercial real-time fluorescence particle sensors and a Sporewatch single-stage particle impactor were operated continuously from 2 August to 2 September 2010 at a rural sampling location in Killarney National Park in southwestern Ireland. A cascade impactor was operated periodically to collect size-resolved particles during exemplary periods. Here we report the first ambient comparison of a waveband integrated bioaerosol sensor (WIBS-4) with a ultraviolet aerodynamic particle sizer (UV-APS) and also compare these real-time fluorescence techniques with results of fluorescence and optical microscopy of impacted samples. Both real-time instruments showed qualitatively similar behavior, with increased fluorescent bioparticle concentrations at night, when relative humidity was highest and temperature was lowest. The fluorescent particle number from the FL3 channel of the WIBS-4 and from the UV-APS were strongly correlated and dominated by a 3 μm mode in the particle size distribution. The WIBS FL2 channel exhibited particle modes at approx. 1 and 3 μm, and each was correlated with the concentration of fungal spores commonly observed in air samples collected at the site (ascospores, basidiospores, Ganoderma spp.). The WIBS FL1 channel exhibited variable multimodal distributions turning into a broad featureless single mode after averaging, and exhibited poor correlation with fungal spore concentrations, which may be due to the detection of bacterial and non-biological fluorescent particles. Cladosporium spp., which are among the most abundant fungal spores in many terrestrial environments, were not correlated with any of the real-time fluorescence channels, suggesting that the real-time fluorescence instruments are relatively insensitive to PBAP classes with dark, highly absorptive cell walls. Fluorescence microscopy images of cascade impactor plates showed large numbers of coarse-mode particles consistent with the morphology and weak fluorescence expected of sea salt. Some of these particles were attached to biological cells, suggesting that a marine source influenced the PBAPs observed at the site and that the ocean may be an important contributor to PBAP loadings in coastal environments.


Atmosphere ◽  
2017 ◽  
Vol 9 (1) ◽  
pp. 1 ◽  
Author(s):  
Mehael Fennelly ◽  
Gavin Sewell ◽  
Michael Prentice ◽  
David O’Connor ◽  
John Sodeau

1994 ◽  
Vol 66 (9) ◽  
pp. 1403-1407 ◽  
Author(s):  
Kimberly A. Prather ◽  
Trent. Nordmeyer ◽  
Kimberly. Salt

2008 ◽  
Vol 16 (21) ◽  
pp. 16523 ◽  
Author(s):  
Hermes C. Huang ◽  
Yong-Le Pan ◽  
Steven C. Hill ◽  
Ronald G. Pinnick ◽  
Richard K. Chang

2012 ◽  
Vol 12 (24) ◽  
pp. 11997-12019 ◽  
Author(s):  
J. A. Huffman ◽  
B. Sinha ◽  
R. M. Garland ◽  
A. Snee-Pollmann ◽  
S. S. Gunthe ◽  
...  

Abstract. As a part of the AMAZE-08 campaign during the wet season in the rainforest of central Amazonia, an ultraviolet aerodynamic particle sizer (UV-APS) was operated for continuous measurements of fluorescent biological aerosol particles (FBAP). In the coarse particle size range (> 1 μm) the campaign median and quartiles of FBAP number and mass concentration were 7.3 × 104 m−3 (4.0–13.2 × 104 m−3) and 0.72 μg m−3 (0.42–1.19 μg m−3), respectively, accounting for 24% (11–41%) of total particle number and 47% (25–65%) of total particle mass. During the five-week campaign in February–March 2008 the concentration of coarse-mode Saharan dust particles was highly variable. In contrast, FBAP concentrations remained fairly constant over the course of weeks and had a consistent daily pattern, peaking several hours before sunrise, suggesting observed FBAP was dominated by nocturnal spore emission. This conclusion was supported by the consistent FBAP number size distribution peaking at 2.3 μm, also attributed to fungal spores and mixed biological particles by scanning electron microscopy (SEM), light microscopy and biochemical staining. A second primary biological aerosol particle (PBAP) mode between 0.5 and 1.0 μm was also observed by SEM, but exhibited little fluorescence and no true fungal staining. This mode may have consisted of single bacterial cells, brochosomes, various fragments of biological material, and small Chromalveolata (Chromista) spores. Particles liquid-coated with mixed organic-inorganic material constituted a large fraction of observations, and these coatings contained salts likely from primary biological origin. We provide key support for the suggestion that real-time laser-induce fluorescence (LIF) techniques using 355 nm excitation provide size-resolved concentrations of FBAP as a lower limit for the atmospheric abundance of biological particles in a pristine environment. We also show some limitations of using the instrument for ambient monitoring of weakly fluorescent particles < 2 μm. Our measurements confirm that primary biological particles, fungal spores in particular, are an important fraction of supermicron aerosol in the Amazon and that may contribute significantly to hydrological cycling, especially when coated by mixed inorganic material.


Sign in / Sign up

Export Citation Format

Share Document