Laser induced self-N-doped porous graphene as an electrochemical biosensor for femtomolar miRNA detection

Carbon ◽  
2020 ◽  
Vol 163 ◽  
pp. 385-394 ◽  
Author(s):  
Zhengfen Wan ◽  
Muhammad Umer ◽  
Mirko Lobino ◽  
David Thiel ◽  
Nam-Trung Nguyen ◽  
...  
2019 ◽  
Vol 55 (71) ◽  
pp. 10603-10606 ◽  
Author(s):  
Jiafu Chang ◽  
Haiyin Li ◽  
Feng Li

A truly ratiometric homogeneous electrochemical biosensor was developed for miRNA detection based on the unique diffusion/intercalation properties of electroactive dyes.


2020 ◽  
Vol 311 ◽  
pp. 127866 ◽  
Author(s):  
Hyosang Yoon ◽  
Joongsan Nah ◽  
Hyunsik Kim ◽  
Seokgyu Ko ◽  
Md Sharifuzzaman ◽  
...  

2020 ◽  
Vol 1135 ◽  
pp. 73-82 ◽  
Author(s):  
Zhen Yang ◽  
Mingji Li ◽  
Hongji Li ◽  
Huayi Li ◽  
Cuiping Li ◽  
...  

Nanomaterials ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 416
Author(s):  
Zari Tehrani ◽  
Hina Yaqub Abbasi ◽  
Anitha Devadoss ◽  
Jonathan Edward Evans ◽  
Owen James Guy

Electrochemical biosensors using carbon-based electrodes are being widely developed for the detection of a range of different diseases. Since their sensitivity depends on the surface coverage of bioreceptor moieties, it necessarily depends on the surface coverage of amine precursors. Electrochemical techniques, using ferrocene carboxylic acid as a rapid and cheap assay, were used to assess the surface coverage of amino-phenyl groups attached to the carbon electrode. While the number of electrons transferred in the first step of diazotisation indicated a surface coverage of 8.02 ± 0.2 × l0−10 (mol/cm2), and those transferred in the second step, a reduction of nitrophenyl to amino-phenyl, indicated an amine surface coverage of 4–5 × l0−10 (mol/cm2), the number of electrons transferred during attachment of the amine coupling assay compound, ferrocene carboxylic acid, indicated a much lower available amine coverage of only 2.2 × l0−11 (mol/cm2). Furthermore, the available amine coverage was critically dependent upon the number of cyclic voltammetry cycles used in the reduction, and thus the procedures used in this step influenced the sensitivity of any subsequent sensor. Amine coupling of a carboxyl terminated anti-beta amyloid antibody specific to Aβ(1-42) peptide, a potential marker for Alzheimer’s disease, followed the same pattern of coverage as that observed with ferrocene carboxylic acid, and at optimum amine coverage, the sensitivity of the differential pulse voltammetry sensor was in the range 0–200 ng/mL with the slope of 5.07 µA/ng·mL−1 and R2 = 0.98.


Author(s):  
Jing Zhang ◽  
Meifeng Hou ◽  
Guanyu Chen ◽  
Huifang Mao ◽  
Wenqian Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document