Field emission and electron beam transmission characteristics of microtips array on the (100) plane of single-crystal Gadolinium hexaboride ceramic

Author(s):  
Weikang Liu ◽  
Xin Zhang ◽  
Hongliang Liu ◽  
Jichao Li ◽  
Ning Zhou ◽  
...  
Author(s):  
B.G. Frost ◽  
D.C. Joy ◽  
L.F. Allard ◽  
E. Voelkl

A wide holographic field of view (up to 15 μm in the Hitachi-HF2000) is achieved in a TEM by switching off the objective lens and imaging the sample by the first intermediate lens. Fig.1 shows the corresponding ray diagram for low magnification image plane off-axis holography. A coherent electron beam modulated by the sample in its amplitude and its phase is superimposed on a plane reference wave by a negatively biased Möllenstedt-type biprism.Our holograms are acquired utilizing a Hitachi HF-2000 field emission electron microscope at 200 kV. Essential for holography are a field emission gun and an electron biprism. At low magnification, the excitation of each lens must be appropriately adjusted by the free lens control mode of the microscope. The holograms are acquired by a 1024 by 1024 slow-scan CCD-camera and processed by the “Holoworks” software. The hologram fringes indicate positively and negatively charged areas in a sample by the direction of the fringe bending (Fig.2).


2016 ◽  
Vol 1 (2) ◽  
Author(s):  
Navitha M ◽  
Jitendra Nigam ◽  
Silambarasan N S ◽  
Piyush Kumar ◽  
Pavan Kumar

INTRODUCTION: Superficial tumors are treated with electron beams. Shielding blocks are used to conform to the shape of the tumor. These shielding blocks are usually kept at lower level of the applicator which is near the skin surface. The scattering property of electron may increase the surface dose which will increase with increasing electron energies. The purpose of this study is to compare electron beam transmission of different energies with two different block materials at different placement positions within the applicator. MATERIAL AND METHODS: Cerrobend alloy (50%bismuth, 26.7%lead, 13.3%tin and 10%cadmium) and 1mm thick lead sheets (94%lead, 6%alloy) in Varian Clinac2300C/D linear accelerator with electron energies 6,9,12,16 and 20MeVs using 10x10 applicator at 3 different holding levels was used. Measurements with RW3 Slab phantom (Water equivalent), PPC05 Parallel Plane Chamber, Dose 1 electrometer was done. The slab phantom 30x30x10 cm3 aligned with PPC05 Parallel Plane Chamber (at R85 of respective energies). Readings measured for open and block fields, for different thickness of shielding material, at different placement positions within the applicator. The percentage transmission calculated manually. RESULTS: Using electron energies 6,9,12,16, and 20MeVs respectively the transmission% were: with lead sheet 1mm thickness-2.48%,8.69%,16.05%, 28.03% and 39.50% at lower placement position, 1.19%,3.76%,7.75%,15% and 23.99% at centre placement and 0.96%,3.02%,6.15% and 20.27% for upper placement; with 2mm thickness-0.89%,1.62%,3.66%, 8.95% and 16.35% at lower level, 0.60%,1.28%,2.54%,5.74% and 10.72% at centre level and 0.57%,0.94%, 2.12%,4.85% and 9.22% at upper level; with 3mm thickness-0.80%,1.53%,2.88%,5.29% and 9.42% at lower position, 0.52%,1.25%,2.06%,4.03% and 7.36% at centre position and 0.51%, 0.90%,1.78%,3.66% and 6.43% at upper position; with 4mm thickness- 0.75%,1.40%, 2.71%,4.81% and 7.76% at lower level, 0.50%,1.18%,1.95%,3.68% and 6.31% at center level and 0.51%,0.80%, 1.70%,3.34% and 5.65% at upper level; with 5mm thickness-0.73%, 1.30%,2.57%,4.56% and 7.20% at lower level, 0.45%,1.06%,1.81%,3.48% and 5.68% at center level and 0.47%,0.79%,1.61%,3.13% and 5.24% at upper level. For Cerrobend material 5mm thickness, the transmission at lower level are 0.79%,1.50%,2.98%,5.58% and 10.39%, at center level are 0.52%,0.99%,2.09%,4.12% and 7.67% and at upper level are 0.49%,0.91%, 1.82%,3.75% and 6.90% for the energies 6,9,12,16 and 20 MeV’s respectively. CONCLUSION: There is not much difference in the transmission values at centre and upper levels so as to keep nearer the skin, the centre position in electron applicator may be optimum. Lead sheets can be used since easy to prepare especially for rectangular or square shapes.


Sign in / Sign up

Export Citation Format

Share Document