Performance of agitated-vessel U tube heat exchanger using spiky twisted tapes and water based metallic nanofluids

2018 ◽  
Vol 133 ◽  
pp. 26-39 ◽  
Author(s):  
M. Khoshvaght-Aliabadi ◽  
S. Davoudi ◽  
M.H. Dibaei
2017 ◽  
Vol 6 (4) ◽  
pp. 83 ◽  
Author(s):  
Gaurav Thakur ◽  
Gurpreet Singh

The thermal performance of shell and tube heat exchangers has been enhanced with the use of different techniques. Air bubble injection is one such promising and inexpensive technique that enhances the heat transfer characteristics inside shell and tube heat exchanger by creating turbulence in the flowing fluid. In this paper, experimental study on heat transfer characteristics of shell and tube heat exchanger was done with the injection of air bubbles at the tube inlet and throughout the tube with water based Al2O3 nanofluids i.e. (0.1%v/v and 0.2%v/v). The outcomes obtained for both the concentrations at two distinct injection points were compared with the case when air bubbles were not injected. The outcomes revealed that the heat transfer characteristics enhanced with nanoparticles volumetric concentration and the air bubble injection. The case where air bubbles were injected throughout the tube gave maximum enhancement followed by the cases of injection of air bubbles at the tube inlet and no air bubble injection. Besides this, water based Al2O3 nanofluid with 0.2%v/v of Al2O3 nanoparticles gave more enhancement than Al2O3nanofluid with 0.1%v/v of Al2O3 nanoparticles as the enhancement in the heat transfer characteristics is directly proportional to the volumetric concentration of nanoparticles in the base fluid. The heat transfer rate showed an enhancement of about 25-40% and dimensionless exergy loss showed an enhancement of about 33-43% when air bubbles were injected throughout the tube. Moreover, increment in the heat transfer characteristics was also found due to increase in the temperature of the hot fluid keeping the flow rate of both the heat transfer fluids constant.


2019 ◽  
Vol 25 (8) ◽  
pp. 39-51
Author(s):  
Nassr Fadhil Hussein ◽  
Abdulrahman Shakir Mahmood

Enhancement of heat transfer in the tube heat exchanger is studied experimentally by using discrete twisted tapes. Three different positions were selected for inserting turbulators along tube section (horizontal position by α= 00, inclined position by α= 45 0 and vertical position by α= 900). The space between turbulators was fixed by distributing 5 pieces of these turbulators with pitch ratio    PR = (0.44). Also, the factor of constant heat flux was applied as a boundary condition around the tube test section for all experiments of this investigation, while the flow rates were selected as a variable factor (Reynolds number values vary from 5000 to 15000). The results show that using discrete twisted tapes enhances the heat transfer rate by about 60.7-103.7 % compared with plane tube case. Also, inserting turbulators with inclined position offers maximum heat transfer rate by 103.7%.  


2018 ◽  
Vol 22 (1 Part B) ◽  
pp. 477-485 ◽  
Author(s):  
Mahalingam Arulprakasajothi ◽  
Kariappan Elangovan ◽  
Udayagiri Chandrasekhar ◽  
Sivan Suresh

The objective of the study is to observe the Nusselt number and friction factor behavior in a tube heat exchanger fitted with staggered and non-staggered conical strip inserts using water based titanium oxide nanofluid under laminar flow conditions. Water based titanium oxide nanofluid was prepared using a two-step method with a volume concentration of 0.1% and 0.5%. The tube inserts used were staggered and non-staggered conical strips having three different twist ratios of 2, 3, and 5. The experimental results indicated that the Nusselt number increased in the presence of water based titanium oxide nanofluid compared to the base fluid. Nusselt number further increased enormously with the use of conical strip inserts than a tube with no inserts. It was observed that the strip geometry and the nanofluid had a major effect on the thermal performance of the circular tube heat exchanger. It was found that with the staggered conical strip having a twist ratio of Y = 3 and 0.5% volume concentration of nanofluid provided the highest heat transfer. Correlations have been derived using regression analysis.


Symmetry ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 1652
Author(s):  
Mehdi Ghalambaz ◽  
Ramin Mashayekhi ◽  
Hossein Arasteh ◽  
Hafiz Muhammad Ali ◽  
Pouyan Talebizadehsardari ◽  
...  

This paper investigates the convective heat transfer in a heat exchanger equipped with twisted tape elements to examine effects of the twisted tape truncation percentage, pitch value, position and Reynolds number using 3D numerical simulation. A symmetric heat flux is applied around the tube as the studied heat exchanger. Based on the influences in both heat transfer enhancement and pressure drop, the performance evaluation criterion (PEC) is utilized. Inserting twisted tape elements and reducing the pitch value significantly augment the Nusselt number, friction coefficient and PEC number compared to the plain tube. For the best case with a Reynolds number of 1000, the average Nusselt number increases by almost 151%, which is the case of fully fitted twisted tape at a pitch value of L/4. Moreover, increasing the twisted tape truncation percentage reduces both heat transfer and pressure drop. Furthermore, the highest heat transfer rate is achieved when the truncated twisted tape is located at the entrance of the tube. Finally, it is concluded that for P = L, L/2, L/3 and L/4, the optimum cases from the viewpoint of energy conservation are twisted tapes with truncation percentages of 75, 50, 50 and 0%, in which the related PEC numbers at a Reynolds number of 1000 are almost equal to 1.08, 1.24, 1.4 and 1.76, respectively.