Durable Polymer Drug Eluting Stent-Induced Kounis Syndrome and Eosinophilia Requiring Long-term Immunosuppression

Author(s):  
Thomas Boucher ◽  
Aman M. Shah ◽  
Hayder Hashim ◽  
Elina Jerschow ◽  
Anna E. Bortnick
2020 ◽  
Vol 13 (1) ◽  
pp. 97-111 ◽  
Author(s):  
Jeong Cheon Choe ◽  
Kwang Soo Cha ◽  
Jeong Gyu Lee ◽  
Jinmi Kim ◽  
Ji Yeon Shin ◽  
...  

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
T Tsujimura ◽  
T Ishihara ◽  
O Iida ◽  
M Asai ◽  
M Masuda ◽  
...  

Abstract Background Polymer-free biolimus A9-coated stent (DCS) has currently emerged as expected better arterial healing compared to durable polymer drug-eluting stent (DP-DES). However, superiority of DCS on arterial healing over DP-DES has not been well elucidated using intracoronary images. Methods This study examined 288 stents in 224 patients with de novo coronary artery lesions. We angioscopically compared 55 DCS from 35 patients with 233 DP-DES from 189 patients 10±2 months after the implantation. We assessed thrombus adhesion, which is a marker of incomplete re-endothelialization. Dominant neointimal coverage (NIC) grade, heterogeneity of NIC and maximum yellow color of plaque underneath the stent were also evaluated. Neointimal coverage was graded as follows: grade 0, stent struts exposed; grade 1, struts bulged into the lumen, although covered; grade 2, struts embedded by the neointima, but translucent; grade 3, struts fully embedded and invisible. NIC was judged as heterogeneous when differences in the NIC grade became apparent. Yellow plaque was graded as follows: grade 0, white; grade 1, light yellow; grade 2, yellow; grade 3, intensive yellow. Results Thrombus adhesion was similar between DCS and DP-DES (29% versus 23%, P=0.32). Dominant NIC was greater in DCS than in BP-DES (P<0.001), while NIC was more heterogeneous in DCS than in BP-DES (P=0.001, Figure). Maximum yellow color of stented segment was similar between DCS and DP-DES (P=0.09). Conclusion DCS provided similar thrombus adhesion to DP-DES, which suggested similar re-endothelialization 10 months after implantation. However, DCS showed thick and heterogeneous NIC compared to DP-DES. The specific feature of polymer-free and Biolimus A9 would cause the difference, and further investigation is necessary to evaluate the longer-term safety and efficacy. Acknowledgement/Funding None


2015 ◽  
Vol 8 (7) ◽  
pp. 877-884 ◽  
Author(s):  
Sebastian Kufner ◽  
Salvatore Cassese ◽  
Marco Valeskini ◽  
Franz-Josef Neumann ◽  
Stefanie Schulz-Schüpke ◽  
...  

2015 ◽  
Vol 26 (10) ◽  
pp. 1423-1430 ◽  
Author(s):  
Stavros Spiliopoulos ◽  
Vasiliki Theodosiadou ◽  
Konstantinos Katsanos ◽  
Panagiotis Kitrou ◽  
George C. Kagadis ◽  
...  

Author(s):  
J. J. Coughlan ◽  
Alp Aytekin ◽  
Tobias Koch ◽  
Jens Wiebe ◽  
Tobias Lenz ◽  
...  

2011 ◽  
Vol 146 (1) ◽  
pp. e16-e19 ◽  
Author(s):  
Elio Venturini ◽  
Lucia Magni ◽  
Nicholas G. Kounis

Sign in / Sign up

Export Citation Format

Share Document