scholarly journals Is specimen radiography still necessary in patients with non-palpable breast cancer undergoing breast-conserving surgery using radioactive I-125 seed localization?

2021 ◽  
Vol 69 ◽  
pp. 311-317
Author(s):  
Yvonne E. van Riet ◽  
Robert-Jan Schipper ◽  
Franca van Merrienboer ◽  
Ricardo G. Orsini ◽  
Johanne G. Bloemen ◽  
...  
Breast Care ◽  
2018 ◽  
Vol 14 (5) ◽  
pp. 302-307
Author(s):  
Suniza Jamaris ◽  
Leyla Akpolat-Basci ◽  
Miltiades Stephanou ◽  
Sarah Wetzig ◽  
Yueksel Cubuk ◽  
...  

Background: Significant re-excision rates in breast-conserving surgery (BCS) after neoadjuvant systemic chemotherapy may result from difficulties in defining the surgical target particularly in cases with excellent treatment response. Devices allowing an exact topographic localisation of the lesion in the resected tissue could reduce re-excision rates by optimising the intraoperative detection of involved margins. Methods: 80 patients with invasive breast cancer receiving BCS after neoadjuvant chemotherapy were included in this non-randomized case-control study. 40 patients with specimen radiography performed in a standard approach (control group) were compared to 40 patients with use of a radiopaque tissue transfer system (study group). Results: 19/80 (23.75%) patients required re-excision because of involved margins; among those, 14/40 (35%) were in the control group and 5/40 (12.5%) in the study group. The association between the use of the radiopaque tissue transfer system and the lower re-excision rate was statistically significant (p = 0.023). Conclusion: Our analysis provides a rationale for the routine use of a radiopaque tissue transfer system for specimen radiography in BCS after neoadjuvant chemotherapy for invasive breast cancer in order to reduce re-excision rates.


PLoS ONE ◽  
2020 ◽  
Vol 15 (5) ◽  
pp. e0232690 ◽  
Author(s):  
Melanie Lindenberg ◽  
Anne van Beek ◽  
Valesca Retèl ◽  
Frederieke van Duijnhoven ◽  
Wim van Harten

2012 ◽  
Vol 48 ◽  
pp. S215
Author(s):  
M. Barentsz ◽  
M.A.A.J. van den Bosch ◽  
W.B. Veldhuis ◽  
A.J. Witkamp ◽  
P.J. van Diest ◽  
...  

2021 ◽  
Author(s):  
Benedikt Schaefgen ◽  
Annika Funk ◽  
Peter Sinn ◽  
Thomas Bruckner ◽  
Christina Gomez Andreu ◽  
...  

Abstract PurposeThis is the first study to systematically evaluate the diagnostic accuracy of intraoperative specimen radiography on margin level and its potential to reduce second surgeries in patients treated with neoadjuvant chemotherapy. MethodsThis retrospective study included 174 cases receiving breast conserving surgery (BCS) after neoadjuvant chemotherapy (NACT) of primary breast cancer. Conventional specimen radiography (CSR) was performed to assess potential margin infiltration of the target lesion and recommend an intraoperative re-excision of any radiologically positive margin. The histological workup of the specimen served as gold standard for the evaluation of the accuracy of CSR and the potential reduction of second surgeries by CSR-guided re-excisions. A subgroup analysis was performed for patients with and without clinical complete response. Results 1044 margins were assessed. Of 47 (4.5%) histopathological positive margins, CSR identified 9 correctly (true positive). 38 infiltrated margins were missed (false negative). This resulted in a sensitivity of 19.2%, a specificity of 89.2%, a PPV of 7.7% and a NPV of 95.9%. The rate of secondary procedures was reduced from 23 to 16 with a number needed to treat (NNT) of CSR guided intraoperative re-excisions of 25. In the subgroup of patients with cCR, the prevalence of positive margins was 10/510 (2.0%), PPV was 1.9% and the NNT was 85. ConclusionPositive margins after NACT are rare and CSR has only a low sensitivity to detect them. Thus, the rate of secondary surgeries cannot be significantly reduced by recommending targeted re-excisions, especially in cases with cCR.


Sign in / Sign up

Export Citation Format

Share Document