Multi-objective optimization of an integrated gasification combined cycle for hydrogen and electricity production

2018 ◽  
Vol 117 ◽  
pp. 256-267 ◽  
Author(s):  
Maan Al-Zareer ◽  
Ibrahim Dincer ◽  
Marc A. Rosen
2010 ◽  
Vol 31 (3) ◽  
pp. 145-164 ◽  
Author(s):  
Janusz Kotowicz ◽  
Anna Skorek-osikowska ◽  
Katarzyna Janusz-szymańska

Membrane separation of carbon dioxide in the integrated gasification combined cycle systemsIntegrated gasification combined cycle systems (IGCC) are becoming more popular because of the characteristics, by which they are characterized, including low pollutants emissions, relatively high efficiency of electricity production and the ability to integrate the installation of carbon capture and storage (CCS). Currently, the most frequently used CO2capture technology in IGCC systems is based on the absorption process. This method causes a significant increase of the internal load and decreases the efficiency of the entire system. It is therefore necessary to look for new methods of carbon dioxide capture. The authors of the present paper propose the use of membrane separation. The paper reviews available membranes for use in IGCC systems, indicates, inter alia, possible places of their implementation in the system and the required operation parameters. Attention is drawn to the most important parameters of membranes (among other selectivity and permeability) influencing the cost and performance of the whole installation. Numerical model of a membrane was used, among others, to analyze the influence of the basic parameters of the selected membranes on the purity and recovery ratio of the obtained permeate, as well as to determine the energetic cost of the use of membranes for the CO2separation in IGCC systems. The calculations were made within the environment of the commercial package Aspen Plus. For the calculations both, membranes selective for carbon dioxide and membranes selective for hydrogen were used. Properly selected pressure before and after membrane module allowed for minimization of energy input on CCS installation assuring high purity and recovery ratio of separated gas.


2020 ◽  
pp. 99-111
Author(s):  
Vontas Alfenny Nahan ◽  
Audrius Bagdanavicius ◽  
Andrew McMullan

In this study a new multi-generation system which generates power (electricity), thermal energy (heating and cooling) and ash for agricultural needs has been developed and analysed. The system consists of a Biomass Integrated Gasification Combined Cycle (BIGCC) and an absorption chiller system. The system generates about 3.4 MW electricity, 4.9 MW of heat, 88 kW of cooling and 90 kg/h of ash. The multi-generation system has been modelled using Cycle Tempo and EES. Energy, exergy and exergoeconomic analysis of this system had been conducted and exergy costs have been calculated. The exergoeconomic study shows that gasifier, combustor, and Heat Recovery Steam Generator are the main components where the total cost rates are the highest. Exergoeconomic variables such as relative cost difference (r) and exergoeconomic factor (f) have also been calculated. Exergoeconomic factor of evaporator, combustor and condenser are 1.3%, 0.7% and 0.9%, respectively, which is considered very low, indicates that the capital cost rates are much lower than the exergy destruction cost rates. It implies that the improvement of these components could be achieved by increasing the capital investment. The exergy cost of electricity produced in the gas turbine and steam turbine is 0.1050 £/kWh and 0.1627 £/kWh, respectively. The cost of ash is 0.0031 £/kg. In some Asian countries, such as Indonesia, ash could be used as fertilizer for agriculture. Heat exergy cost is 0.0619 £/kWh for gasifier and 0.3972 £/kWh for condenser in the BIGCC system. In the AC system, the exergy cost of the heat in the condenser and absorber is about 0.2956 £/kWh and 0.5636 £/kWh, respectively. The exergy cost of cooling in the AC system is 0.4706 £/kWh. This study shows that exergoeconomic analysis is powerful tool for assessing the costs of products.


Author(s):  
S De ◽  
P K Nag

The effect of supplementary firing on the performance of an integrated gasification combined cycle (IGCC) power plant is studied. The results are presented with respect to a simple ‘unfired’ IGCC power plant with single pressure power generation for both the gas and the steam cycles as reference. The gases are assumed as real with variable specific heats. It is found that the most favourable benefit of supplementary firing can be obtained for a low temperature ratio R T only. For higher R T, only a gain in work output is possible with a reverse effect on the overall efficiency of the plant. The second law analysis reveals that the exergy loss in the heat-recovery steam generator is most significant as the amount of supplementary firing increases. It is also noteworthy that, although the total exergy loss of the plant decreases with higher supplementary firing for a low R T (= 3.0), the reverse is the case for a higher R T (= 6.0).


Sign in / Sign up

Export Citation Format

Share Document