Six-week retention after postplacental copper intrauterine device placement

Contraception ◽  
2018 ◽  
Vol 97 (3) ◽  
pp. 215-218 ◽  
Author(s):  
Alyssa Covelli Colwill ◽  
Courtney A. Schreiber ◽  
Mary D. Sammel ◽  
Sarita Sonalkar
Contraception ◽  
2019 ◽  
Vol 100 (3) ◽  
pp. 219-221 ◽  
Author(s):  
Ivana Thompson ◽  
Jessica N Sanders ◽  
E Bimla Schwarz ◽  
Christy Boraas ◽  
David K Turok

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jane Duncan ◽  
Kathryn Fay ◽  
Jessica Sanders ◽  
Benjamin Cappiello ◽  
Jane Saviers-Steiger ◽  
...  

Abstract Background This biomechanical analysis of hysterectomy specimens assesses the forces associated with intrauterine device placement. These include compressive forces required to cause uterine perforation with two commonly available commercial intrauterine device placement instruments and a metal uterine sound. Methods We obtained hysterectomy specimens at a single academic center. All specimens resulted from excision for benign conditions in premenopausal women by any operative method. Within one hour of excision, we stabilized uterine specimens in an apparatus specifically designed for this analysis. A single, experienced clinician performed all experimental maneuvers and measured forces with a Wagner FDIX-25 force gauge. The investigator applied traction on a tenaculum to approximate force used during an intrauterine device placement. The maximum compressive force to the uterine fundus was determined by using manufacturers’ placement instruments for two commercially available products and a metal sound. Results Sixteen individuals provided hysterectomy specimens. No complete perforations occurred while using loaded intrauterine devices; in a single observation the LNG IUS entered the myometrium. The plastic intrauterine device placement rod bowed in all attempts and did not perforate the uterine serosa at the fundus. A metal uterine sound created a complete perforation in all specimens (p < .001). The lowest mean maximum force generated occurred with the levonorgestrel intrauterine system placement instrument 12.3 N (SD ± 3.8 N), followed by the copper T380A intrauterine device placement instrument 14.1 N (SD ± 4.0 N), and highest for the metal sound 17.9 N (SD ± 7.6 N) (p < 0.01). Conclusions In this ex-vivo model, metal uterine sounds caused complete perforation and intrauterine device placement instruments did not. This study received Institutional Review Board (IRB0059096) approval.


2019 ◽  
Vol 221 (6) ◽  
pp. 672
Author(s):  
K. Peebles ◽  
F.M. Kiweewa ◽  
T. Palanee-Phillips ◽  
C. Chappell ◽  
D. Singh ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document