Preparation and corrosion behavior of the Al-modified MoSi2/Al2O3 coating on the surface of molybdenum metal core

2021 ◽  
pp. 109879
Author(s):  
Chong Zhang ◽  
Hanxu Feng ◽  
Zhi Zheng ◽  
Likui Ning ◽  
Jian Tong ◽  
...  
Coatings ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 275
Author(s):  
Chong Zhang ◽  
Enze Liu ◽  
Zhi Zheng ◽  
Likui Ning ◽  
Jian Tong ◽  
...  

This work designs a silica (SiO2) layer on a molybdenum metal core to provide new insights on the corrosion resistance of the silica/silicide coating in the Ni-based superalloy. The molybdenum substrate coated with MoSi2 by pack cementation was pre-oxidized to fabricate a cristobalite scale on the surface and the preoxidation specimens were chosen to examine the corrosion-resistant property by using a DSM11 superalloy at 1550 °C. In order to prepare a cristobalite layer, the microstructure evolution of a 40- µm MoSi2 coating with the different oxidation parameters (temperature and time) was investigated. After casting test, the different casting results showed that the silicide layer was dissolved in the molten superalloy. However, the molybdenum matrix was found to be protected by the cristobalite layer, as well as accompanied by the cristobalite layer partially destroyed at the core/superalloy interfaces. Furthermore, the reason for the destruction of cristobalite layer was analyzed. The failure mechanism of the cristobalite layer was proposed during the cast process.


Author(s):  
Ann Chidester Van Orden ◽  
John L. Chidester ◽  
Anna C. Fraker ◽  
Pei Sung

The influence of small variations in the composition on the corrosion behavior of Co-Cr-Mo alloys has been studied using scanning electron microscopy (SEM), energy dispersive x-ray analysis (EDX), and electrochemical measurements. SEM and EDX data were correlated with data from in vitro corrosion measurements involving repassivation and also potentiostatic anodic polarization measurements. Specimens studied included the four alloys shown in Table 1. Corrosion tests were conducted in Hanks' physiological saline solution which has a pH of 7.4 and was held at a temperature of 37°C. Specimens were mechanically polished to a surface finish with 0.05 µm A1203, then exposed to the solution and anodically polarized at a rate of 0.006 v/min. All voltages were measured vs. the saturated calomel electrode (s.c.e.).. Specimens had breakdown potentials near 0.47V vs. s.c.e.


1980 ◽  
Vol 41 (C8) ◽  
pp. C8-862-C8-866
Author(s):  
M. Naka ◽  
K. Hashimoto ◽  
K. Asami ◽  
T. Masumoto

2018 ◽  
Vol 14 (1) ◽  
pp. 1
Author(s):  
Prof. Dr. Jamal Aziz Mehdi

The biological objectives of root canal treatment have not changed over the recentdecades, but the methods to attain these goals have been greatly modified. Theintroduction of NiTi rotary files represents a major leap in the development ofendodontic instruments, with a wide variety of sophisticated instruments presentlyavailable (1, 2).Whatever their modification or improvement, all of these instruments have onething in common: they consist of a metal core with some type of rotating blade thatmachines the canal with a circular motion using flutes to carry the dentin chips anddebris coronally. Consequently, all rotary NiTi files will machine the root canal to acylindrical bore with a circular cross-section if the clinician applies them in a strictboring manner


2013 ◽  
Vol 51 (1) ◽  
pp. 033-039
Author(s):  
Hae Woo Lee ◽  
Jae Hyeok Jeon ◽  
Ja Young Hong

2015 ◽  
Vol 30 (6) ◽  
pp. 627
Author(s):  
YE Zuo-Yan ◽  
LIU Dao-Xin ◽  
LI Chong-Yang ◽  
ZHANG Xiao-Hua ◽  
ZANG Xiao-Ming ◽  
...  

2008 ◽  
Author(s):  
Yutaka Yokoyama ◽  
Rieko Takahashi ◽  
Hidekazu Asano ◽  
Naoki Taniguchi ◽  
Morimasa Naito

2020 ◽  
Vol 61 (9) ◽  
pp. 1775-1781
Author(s):  
Li-Bin Niu ◽  
Shoichi Kosaka ◽  
Masaki Yoshida ◽  
Yusuke Suetake ◽  
Kazuo Marugame