scholarly journals Strengthening of reinforced concrete beams without transverse reinforcement by using intraply hybrid composites

2021 ◽  
Vol 15 ◽  
pp. e00700
Author(s):  
Ferit Cakir ◽  
Volkan Acar ◽  
M. Raci Aydin ◽  
Bora Aksar ◽  
Pinar Yildirim
2019 ◽  
Vol 21 (2) ◽  
pp. 484-500
Author(s):  
Nasim Shatarat ◽  
Rozan Hunifat ◽  
Yasmin Murad ◽  
Hasan Katkhuda ◽  
Mu'tasim Abdel Jaber

Author(s):  
Igor Souza Hoffman ◽  
Jorge Henrique Piva ◽  
Augusto Wanderlind ◽  
Elaine Guglielmi Pavei Antunes

abstract: The use of GFRP (Glass Fiber Reinforced Polymers) structural profiles in the construction sector is growing due to their attractive properties, such as high mechanical strength and durability in aggressive environments. With this, it is necessary to conduct studies that deepen the knowledge about the performance of these materials in structural applications. Therefore, this work aims to analyze the mechanical performance of reinforced concrete beams coated with GFRP profiles, in comparison to reinforced concrete beams, by analyzing groups with different spacing between transversal reinforcement. In all groups there was no change in the longitudinal reinforcement, and the D and Q groups were, respectively, made up of transverse reinforcement spaced twice and quadruple the one calculated for the reference beams, and presented the GFRP profiles in their constitution. All beams were tested at four-point bending, and strain gauges were installed in one of the beams of each group studied. The results obtained in the tests showed an increase in strength of 83.67% in the beams of group D, and 79.91% for group Q, in relation to the references. The analysis of longitudinal deformations made it possible to verify increases in stiffness and the moment of cracking in composite beams. Thus, based on this study, the composite structures studied may constitute future solutions for constructions exposed to aggressive environmental conditions, in order to increase their durability and also to contribute to the design of such structural elements with lower reinforcement rates.


2014 ◽  
Vol 41 (7) ◽  
pp. 594-604 ◽  
Author(s):  
Mehrollah Rakhshanimehr ◽  
M. Reza Esfahani ◽  
M. Reza Kianoush ◽  
B. Ali Mohammadzadeh ◽  
S. Roohollah Mousavi

In this paper, the flexural ductility of lap-spliced reinforced concrete (RC) beams is experimentally investigated. Twenty-four specimens were designed and manufactured for laboratory experiments. Concrete compressive strength, amount of transverse reinforcement over the splice length, and the diameter of longitudinal bars were selected as the main variables. The ductility of tested specimens is evaluated based on a previously defined ductility ratio. Results show that concrete strength and amount of transverse reinforcement over the splice have major effects on ductility. With an appropriate amount of transverse reinforcement, a satisfactory ductility response for different concrete strengths can be obtained. The CSA-A23.3-04 Standard provisions on bond strength and ductility of lap-spliced RC beams are evaluated and discussed. This study shows that the provisions in predicting the bond strength of lap-spliced concrete beams are adequate but may not achieve a satisfactory performance for ductility. An equation is proposed to achieve the appropriate ductility.


1989 ◽  
Vol 16 (1) ◽  
pp. 36-44
Author(s):  
B. MacKay ◽  
D. Schmidt ◽  
T. Rezansoff

Proposals from Cornell University for seismic design of lap splices, where the strength provided to the lap splice by the concrete confinement is considered insignificant, were evaluated. The concrete confining the splice length is assumed to deteriorate after high-intensity (inelastic) reversed load cycling so that the performance is mainly dependent on the amount of transverse reinforcement provided to confine the lap splice. Lap lengths of 30–40 bar diameters are proposed, along with heavy transverse reinforcement. Longer lap lengths are considered to be less effective. By contrast, for static loading the concrete confining the splice is known to play a major role in transferring load between the bars along the splice.The current program consisted of testing six reinforced concrete beams under fully reversed cycled loading. The three similar beams in each of the two series contained equal stirrup confinement (number of stirrups) along the lap length to satisfy the Cornell University recommendations for seismic loading for the measured reinforcing yield strength, while the splice length was varied. Splices were located in the bottom face of the test beams and were positioned in a region of maximum moment to ensure severe stressing. Each series of specimens exhibited only small strength gains with increasing splice lengths; however, the performance, when evaluated on the basis of the ductility achieved and the hysteretic energy absorbed prior to failure, was superior with long splices. Since the main reinforcement in the test beams was loaded past yielding, large increases in deformation capacity resulted in only small increases in load.Full reversal inelastic load cycling is very detrimental to the concrete that confines the splice region when compared to static (monotonic) loading or one-directional repeated loading to failure. Splice failure loads under reversal loading in the current study were below predicted static strengths for the same beam configurations, and with the longer lap lengths, static failure would have been flexural rather than in the splice. Key words: reinforced concrete, beams, splices (lap), confinement, seismic design, cycled loading, ductility, strength.


2020 ◽  
Vol 17 (4) ◽  
Author(s):  
Sergio Luis González Garcia ◽  
Caroline Vieira Lannes ◽  
Luiz Antônio Vieira Carneiro ◽  
Rancés Castillo Lara

Author(s):  
Lubna Mohammed Abd

   In this research, (12) normal reinforced concrete beams are used with dimensions (110*10*20) cm, the compressive strength for all specimens is 30 MPa. Longitudinal steel is deformed bars 2Ø12mm with Ø6 mm transverse reinforcement which is deformed bars also for different spacing 5 cm, 10 cm and 15 cm. After casting  the specimens and removing them from the molds, they left for about 28 days. They tied by CFRP strips  with different shapes of tying (tied, inclined and X- shaped). They are all testing with two points load by a hydraulic machine for determining (Pu, P cr, maximum deflection and modes of failure) and compared among  their results with the specimens without CFRP strips. From the experimental program, the excellent behavior of the specimens with the X-shaped strips especially with the Pu which is 70% increment and maximum deflection is 39%  decrement. The addition of CFRP strips as a tying material helps to increase the strength of concrete and bearing against loads also, changes and decreases the flexural and shear failure and combined failure.


Sign in / Sign up

Export Citation Format

Share Document