Effectiveness of concrete confinement on lap splice performance in concrete beams under reversed inelastic loading

1989 ◽  
Vol 16 (1) ◽  
pp. 36-44
Author(s):  
B. MacKay ◽  
D. Schmidt ◽  
T. Rezansoff

Proposals from Cornell University for seismic design of lap splices, where the strength provided to the lap splice by the concrete confinement is considered insignificant, were evaluated. The concrete confining the splice length is assumed to deteriorate after high-intensity (inelastic) reversed load cycling so that the performance is mainly dependent on the amount of transverse reinforcement provided to confine the lap splice. Lap lengths of 30–40 bar diameters are proposed, along with heavy transverse reinforcement. Longer lap lengths are considered to be less effective. By contrast, for static loading the concrete confining the splice is known to play a major role in transferring load between the bars along the splice.The current program consisted of testing six reinforced concrete beams under fully reversed cycled loading. The three similar beams in each of the two series contained equal stirrup confinement (number of stirrups) along the lap length to satisfy the Cornell University recommendations for seismic loading for the measured reinforcing yield strength, while the splice length was varied. Splices were located in the bottom face of the test beams and were positioned in a region of maximum moment to ensure severe stressing. Each series of specimens exhibited only small strength gains with increasing splice lengths; however, the performance, when evaluated on the basis of the ductility achieved and the hysteretic energy absorbed prior to failure, was superior with long splices. Since the main reinforcement in the test beams was loaded past yielding, large increases in deformation capacity resulted in only small increases in load.Full reversal inelastic load cycling is very detrimental to the concrete that confines the splice region when compared to static (monotonic) loading or one-directional repeated loading to failure. Splice failure loads under reversal loading in the current study were below predicted static strengths for the same beam configurations, and with the longer lap lengths, static failure would have been flexural rather than in the splice. Key words: reinforced concrete, beams, splices (lap), confinement, seismic design, cycled loading, ductility, strength.

2019 ◽  
Vol 21 (2) ◽  
pp. 484-500
Author(s):  
Nasim Shatarat ◽  
Rozan Hunifat ◽  
Yasmin Murad ◽  
Hasan Katkhuda ◽  
Mu'tasim Abdel Jaber

2011 ◽  
Vol 255-260 ◽  
pp. 504-508
Author(s):  
Li Song ◽  
Zhi Wu Yu

The behavior of materials under repeated loading has been examined, but extended studies are more and more needed especially for damaged reinforced structures such as bridges, where high-cycle fatigue phenomena and corrosion can be significant. In the present paper, a theoretical model based on fatigue performance of materials and stress analysis for cross-section is proposed in order to analyze the fatigue damage of corroded reinforced concrete beams under repeated loads. Further, fatigue life is predicted by applying this method, and the method is evaluated by test results.


Author(s):  
Nazar Oukaili ◽  
Mohammed Khattab

For structural concrete members that may expose to serious earthquake, overload or accident impact, the design of ductility must be given the same importance as the flexural strength. The aim of this investigation is to study the change in ductility of structural concrete flexural members during their exposure to limited cycles of repeated loading. Twenty full-scale beam specimens have been fabricated in to two identical groups; each group consisted of ten specimens. The first group was tested under monotonic static loading to failure and regarded as control beams, while the specimens of the second group were subjected to ten cycles of repeated loading with constant load interval, which ranged between 40% and 60% of ultimate load. Specimens in each group were categorized as follows: two traditional reinforced concrete specimens with different intensity of tension reinforcement; three partially prestressed specimens with bonded strands; three partially prestressed specimens with unbonded strands; and two fully prestressed concrete specimens. The main variable, which was considered for all specimens was the partial prestressing ratio (PPR). It was observed that, the ductility of reinforced concrete beams was insignificantly increased during subjecting to limited repeated loading. For fully prestressed and partially prestressed concrete beams with high level of PPR, the ductility was significantly enhanced, while, it was decreased for specimens with small level of PPR.


2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Constantin E. Chalioris ◽  
Constantin P. Papadopoulos ◽  
Constantin N. Pourzitidis ◽  
Dimitrios Fotis ◽  
Kosmas K. Sideris

This paper presents the findings of an experimental study on the application of a reinforced self-compacting concrete jacketing technique in damaged reinforced concrete beams. Test results of 12 specimens subjected to monotonic loading up to failure or under repeated loading steps prior to total failure are included. First, 6 beams were designed to be shear dominated, constructed by commonly used concrete, were initially tested, damaged, and failed in a brittle manner. Afterwards, the shear-damaged beams were retrofitted using a self-compacting concrete U-formed jacket that consisted of small diameter steel bars and U-formed stirrups in order to increase their shear resistance and potentially to alter their initially observed shear response to a more ductile one. The jacketed beams were retested under the same loading. Test results indicated that the application of reinforced self-compacting concrete jacketing in damaged reinforced concrete beams is a promising rehabilitation technique. All the jacketed beams showed enhanced overall structural response and 35% to 50% increased load bearing capacities. The ultimate shear load of the jacketed beams varied from 39.7 to 42.0 kN, whereas the capacity of the original beams was approximately 30% lower. Further, all the retrofitted specimens exhibited typical flexural response with high values of deflection ductility.


Author(s):  
Igor Souza Hoffman ◽  
Jorge Henrique Piva ◽  
Augusto Wanderlind ◽  
Elaine Guglielmi Pavei Antunes

abstract: The use of GFRP (Glass Fiber Reinforced Polymers) structural profiles in the construction sector is growing due to their attractive properties, such as high mechanical strength and durability in aggressive environments. With this, it is necessary to conduct studies that deepen the knowledge about the performance of these materials in structural applications. Therefore, this work aims to analyze the mechanical performance of reinforced concrete beams coated with GFRP profiles, in comparison to reinforced concrete beams, by analyzing groups with different spacing between transversal reinforcement. In all groups there was no change in the longitudinal reinforcement, and the D and Q groups were, respectively, made up of transverse reinforcement spaced twice and quadruple the one calculated for the reference beams, and presented the GFRP profiles in their constitution. All beams were tested at four-point bending, and strain gauges were installed in one of the beams of each group studied. The results obtained in the tests showed an increase in strength of 83.67% in the beams of group D, and 79.91% for group Q, in relation to the references. The analysis of longitudinal deformations made it possible to verify increases in stiffness and the moment of cracking in composite beams. Thus, based on this study, the composite structures studied may constitute future solutions for constructions exposed to aggressive environmental conditions, in order to increase their durability and also to contribute to the design of such structural elements with lower reinforcement rates.


2020 ◽  
Vol 26 (2) ◽  
pp. 111-128
Author(s):  
Tamara M. Hasan ◽  
Ahmed S. Ali

The massive growth of the automotive industry and the development of vehicles use lead to produce a huge amount of waste tire rubber. Rubber tires are non-biodegradable, resulting in environmental problems such as fire risks. In this search, the flexural behavior of steel fiber reinforced self-compacting concrete (SFRSCC) beams containing different percentages and sizes of waste tire rubbers were studied and compared them with the flexural behavior of SCC and SFRSCC. Micro steel fiber (straight type) with aspect ratio 65 was used in mixes. The replacement of coarse and fine aggregate was 20% and 10% with chip and crumb rubber. Also, the replacement of limestone dust and silica fume was 50%, 25%, and 12% with ground rubber and very fine rubber, respectively. Twelve beams with small-scale (L=1100mm, h = 150mm, b =100mm) were tested under two points loading (monotonic loading). Fresh properties, hardened properties, load-deflection relation, first crack load, ultimate load, and crack width were investigated. Two tested reinforced concrete beams from experimental work were selected as a case study to compare with the results from ABAQUS program (monotonic loading). These two reinforced concrete beams were simulated as a parametric study under repeated loading using this finite element program. The results showed that the flexural behavior of SFRSCC beams containing rubber was acceptable when compared with flexural behavior of SCC and SFRSCC beams (depended on load carrying capacity). Cracks width was decreased with the addition of steel fibers and waste tires rubber.  An acceptable agreement can be shown between the results of numerical analysis and the results obtained from experimental test (monotonic loading). Insignificant ultimate load differences between the results of monotonic loading and repeated loading                                                                                                                                                                                           


Materials ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 7186
Author(s):  
Agha Syed Muhammad Gillani ◽  
Seung-Geon Lee ◽  
Soo-Hyung Lee ◽  
Hyerin Lee ◽  
Kee-Jeung Hong

Twelve full-scale reinforced concrete beams with two tension lap splices were constructed and tested under a four-point loading test. Half of these beams had shorter lap splices than that recommended by American Concrete Institute Building Code ACI 318-19; they failed by bond loss between steel and concrete at the lap splice region before rebar yielding. The other half of the beams were designed with a lap splice length slightly exceeding that recommended by ACI 318-19; they failed by rebar yielding and exhibited a ductile behavior. Several strain gauges were attached to the longitudinal bars in the lap splice region to study the local behavior of deformed bars during loading. The strain in a rebar was maximum at the loaded end of the lap splice and progressively decreased toward the unloaded end because the rebar at this end could not sustain any load. Stress flow discontinuity occurred at the loaded end and caused stress concentration. The effect of this concentration was investigated based on test results. The comparison of bond strengths calculated by existing equations and those of tested specimens indicated that the results agreed well.