scholarly journals Modelling the Energy Future of Switzerland after the Phase Out of Nuclear Power Plants

2015 ◽  
Vol 76 ◽  
pp. 49-58 ◽  
Author(s):  
Paula Díaz Redondo ◽  
Oscar van Vliet
2021 ◽  
Vol 13 (9) ◽  
pp. 5270
Author(s):  
SungSig Bang ◽  
SangYun Park

The Korean Government has been implementing a nuclear phase-out policy since 2017. Nuclear power plants accounted for 30.0% of the total power generation in 2016; this figure fell to 25.9% at the end of 2019, and the average Capacity Factor (CF) of a nuclear power plant approximately dropped from 89.1% to 69.2%. The nuclear phase-out policy presents severe consequences for the sustainable management of the nuclear power industry. Accordingly, the purpose of this study is to analyze the effect of a decrease in the nuclear capacity factor under the nuclear phase-out policy on the depreciation cost per unit using the Straight-Line Method (SLM) and Decelerated Depreciation Method (DDM) and to provide recommendations from a sustainable management perspective. The results show that the decrease in CF of nuclear power plants has a negative impact on sustainable development of the nuclear power industry. DDM is more beneficial than the SLM during this initial stage of depreciation under the nuclear phase-out policy. In addition, in the early stages of projects or immediately after attracting large-scale investments, DDM can offer more positive signs for stockholders by calculating a smaller net loss or a higher net profit.


Author(s):  
Hanspeter Kriesi

This chapter focuses on two partial and one full policy reversal on nuclear politics in Switzerland since the 1970s. The occupation of the construction site of a planned nuclear power plant in 1975 marked the first turning point in nuclear energy policy, ending a period of pro-nuclear consensus. This protest event led to a ten-year moratorium on the construction of new nuclear power plants. The second partial reversal came in 2003, when the construction of new plants was planned. The third, full policy reversal came after the Fukushima catastrophe, which led to the decision to phase out Swiss nuclear power plants. The chapter stresses two Swiss specifics: the high importance of direct democracy on the nuclear issue, as the issue opposition can launch initiatives and de facto subject any nuclear energy decision to referendum, and the comparatively minor role of the Greens because of their lack of issue ownership.


Author(s):  
Marjorie B. Bauman ◽  
Richard F. Pain ◽  
Harold P. Van Cott ◽  
Margery K. Davidson

2010 ◽  
pp. 50-56 ◽  
Author(s):  
Pablo T. León ◽  
Loreto Cuesta ◽  
Eduardo Serra ◽  
Luis Yagüe

Author(s):  
R. Z. Aminov ◽  
A. N. Bayramov ◽  
M. V. Garievskii

The paper gives the analysis of the problem of the primary current frequency regulation in the power system, as well as the basic requirements for NPP power units under the conditions of involvement in the primary regulation. According to these requirements, the operation of NPPs is associated with unloading and a corresponding decrease in efficiency. In this regard, the combination of nuclear power plants with a hydrogen complex is shown to eliminate the inefficient discharge mode which allows the steam turbine equipment and equipment of the reactor facility to operate in the basic mode at the nominal power level. In addition, conditions are created for the generation and accumulation of hydrogen and oxygen during the day, as well as additionally during the nighttime failure of the electrical load which allows them to be used to generate peak power.  The purpose of the article is to assess the systemic economic effect as a result of the participation of nuclear power plants in combination with the hydrogen complex in the primary control of the current frequency in the power sys-tem, taking into account the resource costs of the main equipment. In this regard, the paper gives the justification of cyclic loading of the main equipment of the hydrogen complex: metal storage tanks of hydrogen and oxygen, compressor units, hydrogen-oxygen combustion chamber of vapor-hydrogen overheating of the working fluid in the steam turbine cycle of a nuclear power plant. The methodological foundations for evaluating the working life of equipment under cyclic loading with the participation in the primary frequency control by the criterion of the growth rate of a fatigue crack are described. For the equipment of the hydrogen complex, the highest intensity of loading is shown to occur in the hydrogen-oxygen combustion chamber due to high thermal stresses.  The system economic effect is estimated and the effect of wear of the main equipment under cyclic loading is shown. Under the conditions of combining NPP power units with a hydrogen complex, the efficiency of primary reg-ulation is shown to depend significantly on: the cost of equipment subjected to cyclic loading; frequency and intensity of cyclic loading; the ratio of the tariff for peak electricity, and the cost of electricity of nuclear power plants.  Based on the developed methodology for assessing the effectiveness of the participation of nuclear power plants with a hydrogen complex in the primary frequency control, taking into account the damage to the equipment, the use of the hydrogen complex is shown to provide a tangible economic effect compared with the option of unloading nuclear power plants with direct participation in frequency control.


Sign in / Sign up

Export Citation Format

Share Document