scholarly journals Three-phase unbalanced load control based on load–electricity transfer index

2021 ◽  
Vol 7 ◽  
pp. 312-318
Author(s):  
Jinyuan Pan ◽  
Jian Liu ◽  
Xiaoqian Chen ◽  
Kanghua Zhong
Author(s):  
Raef Aboelsaud ◽  
A. Ibrahim ◽  
Alexander G. Garganeev

<span>In the microgrid systems, three-phase inverter becomes the main power electronic interface for renewable distributed energy resources (DERs), especially for the islanded microgrids in which the power quality is easily affected by unbalanced and nonlinear loads, this is due to the fact that the voltage and frequency of the microgrid are not supported by the main power grid but determined only by the inverters. Therefore, the compensation of the load unbalances and harmonics in autonomous microgrid inverters are getting more attention in power quality research areas. The main purpose of this paper is to represent an overview of the control strategies of various inverters for unbalanced load compensation</span>


Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2688 ◽  
Author(s):  
Mohammad Jafar Hadidian Moghaddam ◽  
Akhtar Kalam ◽  
Mohammad Reza Miveh ◽  
Amirreza Naderipour ◽  
Foad H. Gandoman ◽  
...  

This paper suggests an enhanced control scheme for a four-leg battery energy storage systems (BESS) under unbalanced and nonlinear load conditions operating in the isolated microgrid. Simplicity, tiny steady-state error, fast transient response, and low total harmonic distortion (THD) are the main advantages of the method. Firstly, a new decoupled per-phase model for the three-phase four-leg inverter is presented. It can eliminate the effect of power stage coupling on control design; thus, the three-phase four-leg power inverter can be viewed as three single input single output (SISO) control systems. Then, using an improved orthogonal signal generation method, the per-phase model of the four-leg inverter in the stationary and synchronous frame is derived. As the second step, a per-phase multi-loop control scheme for the four-leg inverter under unbalanced load conditions is suggested. The proposed control strategy has the ability to provide balanced output voltages under unbalanced load conditions by avoiding the need to deal with the symmetrical components. Finally, a multi-resonant harmonic compensator is used to actively prevent low-order harmonic currents to distort the output voltages of the three-phase four-leg grid-forming power converter. Simulations results are also presented to verify the performance of the suggested control strategy.


2014 ◽  
Vol 981 ◽  
pp. 688-694
Author(s):  
Ming Su ◽  
Xue Yan Ma ◽  
Yan Sun

Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same leg conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth leg uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load.


Sign in / Sign up

Export Citation Format

Share Document