scholarly journals Characterizing electrode reactions by multisampling the current in square-wave voltammetry

2016 ◽  
Vol 213 ◽  
pp. 520-528 ◽  
Author(s):  
Valentin Mirceski ◽  
Dariusz Guziejewski ◽  
Monika Bozem ◽  
Ivan Bogeski
2009 ◽  
Vol 74 (10) ◽  
pp. 1489-1501 ◽  
Author(s):  
Marina Zelić ◽  
Milivoj Lovrić

Isopotential points in square-wave voltammetry are described for the first time. Model calculations and real measurements (performed with UO22+ and Eu3+ in perchlorate and bromide solutions, respectively) indicate that such an intersection could be observed when backward components of the net response, resulting from an increase in frequency or reactant concentration, are presented together. The electrode reaction should be fully reversible because quasireversible or slower electron transfer processes give the isopoints only at increasing reactant concentrations but not at increasing square-wave frequencies. The effect could be used as an additional diagnostic criterion for recognition of reversible electrode reactions where products remain dissolved in the electrolyte solution.


1981 ◽  
Vol 59 (24) ◽  
pp. 3326-3333 ◽  
Author(s):  
Louis Ramaley ◽  
Wee Tee Tan

The theory of square wave voltammetry for reversible electrode reactions is expanded to include average currents and currents flowing to a growing drop (single drop square wave polarography) using an expanding plane model. Excellent agreement between theory and experiment was found for the reduction of Fe(III), good agreement for the reduction of Cd(II). The expanding plane model proved superior, but not greatly superior to the simpler theory. For the case of average current the effect on the polarogram of the times at which integration is started and stopped is discussed. Integration decreases sensitivity but increases signal-to-noise ratio. The conditions for maximum analytical usefulness are presented.


2017 ◽  
Vol 7 (3) ◽  
pp. 119
Author(s):  
Milivoj Lovrić

<p style="margin: 0cm 0cm 8pt; line-height: 150%;"><span lang="EN-GB">Three fast and reversible electrode reactions that are connected by two reversible chemical reactions that are permanently in the equilibrium are analysed theoretically for square wave voltammetry. The dependence of peak potentials on the dimensionless equilibrium constants of chemical reactions is calculated. The influence of the basic thermodynamic parameters on the square wave voltammetric responses is analysed.</span></p>


2020 ◽  
Vol 873 ◽  
pp. 114421
Author(s):  
Eduardo Laborda ◽  
José María Gómez-Gil ◽  
Manuela López-Tenés ◽  
Angela Molina

2020 ◽  
Vol 16 (3) ◽  
pp. 341-348
Author(s):  
Surinya Traipop ◽  
Suchada Chuanuwatanakul ◽  
Orawon Chailapakul ◽  
Eakkasit Punrat

Background: Recently, Derris scandens, a Thai herbal medicine with anti-inflammatory activity, is widely used as beverage and supplementary food. When the traditional medicine is a choice for health therapy, the simple and reliable equipment is required to control the suitable consuming amount of the active component. Objective: To develop the electrochemical sensor for genistein determination in Derris scandens with high sensitivity and rapid operation. Methods: An in-house screen-printed electrochemical sensor consisting of a three-electrode system was developed for genistein determination. A silver/silver chloride (Ag/AgCl) reference electrode, a carbon counter electrode and a carbon working electrode were prepared on a 0.3-mm-thick plastic substrate by the screen-printing technique using conductive ink. The dimensions of each sensor were 2.5×1.0 cm. Only 50 µL of sample solution was required on this device for the determination of genistein concentration by rapid response square wave voltammetry. Results: The oxidation peak of genistein appeared with good response in acidic media at a peak potential of 0.6 V. Moreover, the signal was enhanced by modifying the conductive carbon ink with cobalt( II) phthalocyanine. Under the optimized conditions, the linear range was found to be 2.5-150 µM and the detection limit was 1.5 µM. Moreover, the small volume extraction was successfully developed without any further pre-concentration. This proposed method was applied to determine genistein in Derris scandens with satisfying results. Conclusion: The proposed method is promising as an alternative method for genistein determination with facile and fast analysis.