Inductive influence of HV cable lines in urban and suburban areas

2019 ◽  
Vol 176 ◽  
pp. 105944 ◽  
Author(s):  
Ljubivoje M. Popović
Keyword(s):  
2019 ◽  
Vol 10 (12(36)2019) ◽  
pp. 20-30 ◽  
Author(s):  
Krzysztof DOBRZYNSKI ◽  
◽  
Jacek KLUCZNIK ◽  
Zbigniew LUBOSNY ◽  
◽  
...  
Keyword(s):  

2016 ◽  
Vol 7 (2 (24) 2016) ◽  
pp. 30-42
Author(s):  
Henryk BORYN
Keyword(s):  

2014 ◽  
Vol 27 (1) ◽  
pp. 25-39 ◽  
Author(s):  
Ljubivoje Popovic

The paper presents the method for determination of ground fault current distribution in the cases when feeding cable lines are passing through urban and/or suburban areas, or when many relevant data are uncertain, or completely unknown. The problem appears as a consequence of the fact that many of surrounding urban installations are situated under the surface of the ground and cannot be visually determined or verified. On the basis of on site measurements, the developed method enables compensation of all deficiencies of the relevant data about metal installations involved with the fluctuating magnet field appearing along and around of a power line during an unbalanced fault. The presented analytical procedure is based on the fact that certain measurable quantities cumulatively involve the inductive effects of all, known and unknown surrounding metal installations. The performed quantitative analysis points on at the significance of taking into account the existence of surrounding metal installations.


2020 ◽  
pp. 85-88 ◽  
Author(s):  
Nadezhda P. Kondratieva

The article describes the results of the study concerning the effect of the voltage level on current harmonic composition in greenhouses irradiators. It is found that its change affects the level of current harmonics of all types of the studied greenhouse irradiators. With decrease of nominal supply voltage by 10 %, the total harmonic distortion THDi decreases by 9 % for emitters equipped with high pressure sodium lamps (HPSL), by 10 % for emitters with electrode-less lamps and by 3 % for LED based emitters. With increase of nominal supply voltage by 10 %, THDi increases by 23 % for lighting devices equipped with HPSL, by 10 % for irradiators with electrode-less lamps and by 3 % for LED based emitters. Therefore, changes of supply voltage cause the least effect on the level of current harmonics of LED based emitters and then the emitters with electrode-less lamps. Change of the level of supply voltage causes the greatest effect on the level of current harmonics of HPSL based irradiators. Mathematical models of dependence of THDi on the level of supply voltage for greenhouse emitters equipped with LED, electrode-less lamps and HPSL lamps were formulated. These mathematical models may be used for calculations of total current when selecting transformers and supply cable lines for greenhouse lighting devices, for design of new or reconstruction of existing irradiation systems of greenhouse facilities, and for calculation of power losses in power supply networks of greenhouse facilities during feasibility studies for energy saving and energy efficiency increasing projects.


2016 ◽  
Vol 2016 (4) ◽  
pp. 5-7
Author(s):  
V.Yu. Rozov ◽  
◽  
P.N. Dobrodeyev ◽  
A.V. Erisov ◽  
A.O. Tkachenko ◽  
...  

2015 ◽  
Vol 6 (1) ◽  
pp. 63-69
Author(s):  
S. Szegedi ◽  
I. Lázár ◽  
T. Tóth

This article has been withdrawn - upon request by authors - by Akadémiai Kiadó due to suspected plagiarism.


2004 ◽  
Vol 30 (2) ◽  
pp. 233-234
Author(s):  
Gentile-Francesco Ficetola
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document