Influence of height of confined space on explosion and fire safety

2015 ◽  
Vol 76 ◽  
pp. 31-38 ◽  
Author(s):  
Vijay Kumar Cheeda ◽  
Amit Kumar ◽  
K. Ramamurthi
2020 ◽  
pp. 18-23
Author(s):  
A. S. Moshnenko ◽  
E. S. Krivoshey ◽  
I. N. Smirnova

The modern requirements for explosion and fire safety of industrial enterprises are considered. Equipping the production with high-quality explosion-proof electrical equipment ensures the safety of resources and people's lives. Basic concepts are given, principles and classifications are described, international and Russian standards are indicated, which should be followed by manufacturers of such devices.


2013 ◽  
Vol 21 (8) ◽  
pp. 61-67
Author(s):  
V.N. CHERKASOV ◽  
◽  
A.S. KHARLAMENKOV ◽  

2016 ◽  
Vol 9 (2) ◽  
pp. 54-57
Author(s):  
Николенко ◽  
S. Nikolenko ◽  
Сазонова ◽  
Svetlana Sazonova ◽  
Манохин ◽  
...  

The basic requirements for safety and fire and explosion dangerous and toxic plants for asphalt plants. The assessment of working conditions at the facilities is made subject to these requirements


2009 ◽  
Vol 52 (10) ◽  
pp. 459-461
Author(s):  
S. K. Akshanashev ◽  
L.A. Zinov’ev ◽  
Yu.B. Icheva ◽  
E.S. Torokhova ◽  
E.A. Yakovlev

2021 ◽  
pp. 30-35
Author(s):  
O.V. Melekhina ◽  
M.A. Hamula ◽  
R.A. Eredzhibok

Underground gas storage is an element of the gas transportation system. This is the technological process of injection, offtake, storage of gas. Emergency situations associated with burst releases are possible. An absorber is potentially dangerous equipment in the location of main structures. The loss of containment and violation of operating conditions leads to explosions of high power. Analysis of accidents involving loss of containment in equipment is carried out.


2014 ◽  
Vol 57 (11) ◽  
pp. 448-452 ◽  
Author(s):  
N. I. Akinin ◽  
A. A. Matveev

2020 ◽  
pp. 60-64
Author(s):  
Николай Яковлевич Илюшов ◽  
Надежда Станиславовна Корыткина

В высоковольтном электрооборудовании теплоотводящей и изолирующей средой служит преимущественно масло минерального происхождения, которое обладает хорошими диэлектрическими и теплопроводными свойствами, но является взрывоопасным и биологически неразложимым горючим. Многие исследователи говорят о том, что масло растительного происхождения лучше минерального с точки зрения температурных характеристик и утилизации. Но стоит отметить, что вывод о повышении пожаровзрывобезопасности электрооборудования за счет перехода на растительные масла сделан только на том основании, что температура вспышки у минеральных масел в два раза ниже. При этом совсем не учитывался фактор увеличения объема паров масла и газов в трансформаторном баке под действием дугового разряда, возникающего при межвитковых замыканиях. В настоящей статье предпринята попытка численно доказать влияние электроизоляционной жидкости на основе растительных масел на взрыво- и пожаробезопасность высоковольтного трансформатора при возникновении перенапряжений. Explosion of the transformer can occur under the influence of both external (lightning) and internal (switching, arc) overvoltages. It is necessary to carry out checks of the condition of the insulating material during operation in order to timely detect developing failures and prevent accidental failures due to partial discharges on the equipment. In high-voltage electrical equipment, and in particular in transformers, the heat-removing and insulating medium is mainly mineral oil, due to its good dielectric and heat-conducting properties, but it is combustible, explosive and biodegradable. Currently, it is of interest to use plant materials for the production of insulating liquids. In our country, this is still experimental development, which, however, has practical applications abroad. Many researchers say that vegetable oil is better than mineral oil in terms of temperature characteristics and disposal. But it is worth noting that the conclusion about the increased fire and explosion safety of electrical equipment due to the transition to vegetable oils is made only on the basis that the flash point of mineral oils is two times lower. In this case, the factor of increasing the volume of oil and gas vapours in the transformer tank under the action of arc discharge arising from inter-turn faults was not taken into account at all. This article presents an attempt to numerically prove the effect of an insulating liquid on explosion and fire safety in the event of overvoltage using a boiling point in high-voltage equipment, and in particular in transformers. The research results reflect the effect on the possibility of explosion of the transformer and its ignition of vegetable oil. As a result of calculation there was obtained the excess pressure in the transformer for two types of oils. When solving the problem, the influence of the electric energy of the arc on the volume of gases formed in the oil was taken into account. As an example, for a specific type of transformer, overpressure is determined, leading to the destruction of the tank, which indicates the practical significance of the materials presented in the article.


Sign in / Sign up

Export Citation Format

Share Document