Furan in the baby-food samples purchased from the Finnish markets – Determination with SPME–GC–MS

2009 ◽  
Vol 117 (3) ◽  
pp. 522-528 ◽  
Author(s):  
Marika Jestoi ◽  
Talvikki Järvinen ◽  
Eila Järvenpää ◽  
Heli Tapanainen ◽  
Suvi Virtanen ◽  
...  
Keyword(s):  
2015 ◽  
Vol 93 (5) ◽  
pp. 518-525 ◽  
Author(s):  
Ebrahim Ghorbani-Kalhor ◽  
Rahim Hosseinzadeh-Khanmiri ◽  
Mirzaagha Babazadeh ◽  
Jafar Abolhasani ◽  
Akbar Hassanpour

This work describes the synthesis and application of a novel magnetic metal-organic framework (MOF) [(Fe3O4-2,5-dimercapto-1,3,4-thiadiazole)/Cu3(benzene-1,3,5-tricarboxylate)2] to preconcentrate trace amounts of Cd(II), Pb(II), and Zn(II) ions. A Box–Behnken design was used to find the parameters affecting the preconcentration procedure through response surface methodology. Three variables including sorption time, amount of the magnetic sorbent, and sample pH were selected as affecting factors in the sorption step, and four parameters including type, volume, concentration of the eluent, and elution time were selected in the elution step for the optimization study. These values were 33 mg, 11 min, 5.7 EDTA, 4.3 mL, 0.64 mol L–l EDTA solution, 16 min, for amount of the magnetic sorbent, sorption time, sample pH, type, volume, and concentration of the eluent, and elution time, respectively. Following the sorption and elution steps, the ions were quantified by FAAS. The limits of detection were 0.10, 0.15, and 0.75 ng mL−1 for Cd(II), Zn(II), and Pb(II) ions, respectively. The relative standard deviations (RSD) of the method were less than 8.3% for five separate batch experiments in the determination of 25 μg L−1 of Cd(II), Zn(II), and Pb(II) ions. The sorption capacity of the magnetic MOF nanocomposite was 155 mg g−1 for Cd(II), 173 mg g−1 for Pb(II), and 190 mg g−1 for Zn(II). Finally, the magnetic MOF nanocomposite was successfully applied to rapidly extract trace amounts of heavy metal ions in baby food samples.


2013 ◽  
Vol 60 ◽  
pp. 514-519 ◽  
Author(s):  
Mehmet Fatih Cengiz ◽  
Cennet Pelin Boyacı Gündüz
Keyword(s):  

1980 ◽  
Vol 43 (5) ◽  
pp. 340-342 ◽  
Author(s):  
R. S. SINGH ◽  
SUKHBIR SINGH ◽  
V. K. BATISH ◽  
B. RANGANATHAN

Ten samples of baby foods comprising seven brands of infant milk foods and three brands of milk-cereal weaning foods were examined for incidence of different types of microorganisms. One brand of infant milk food with 91 × 102 organisms also exhibited the maximum number of staphylococci and some of these were coagulase positive. Some staphylococcal isolates showed thermostable deoxyribonuclease (DNase) activity and also produced enterotoxins A or B. One sample of weaning food showed high counts of Bacillus cereus. In one of the reconstituted baby food samples when held at ambient temp. (37.5 C), the Staphylococcus aureus and B. cereus counts increased 10-fold in 3 h.


2006 ◽  
Vol 164 ◽  
pp. S271-S272 ◽  
Author(s):  
Hande Sipahi ◽  
Ayse Eken ◽  
Ahmet Aydin ◽  
Gonul Sahin ◽  
Terken Baydar

2011 ◽  
Vol 7 (3) ◽  
pp. 1421-1433
Author(s):  
Farnaz Ansar Khameneh ◽  
Majid Baghdadi ◽  
Zahra Monsef Khoshhesab

A cloud point extraction procedure was used for preconcentration and determination of trace amount of cadmium ion in real water and baby food samples by microinjection flame atomic absorption spectrometry and with using new synthesis dithiocarbamate ligand. The method is based on cloud point extraction of cadmium using triton X-114 as nonionic surfactant. A certain amount of ligand (Complexing Agent) and surfactant was added to samples and after pH adjustment; the sample was heated in a water bath. A hydrophobic complex was formed between cadmium and [N-(2-phenylethyl) dithiocarbamate] ligand and followed by its extraction into triton X-114 surfactant-rich phase.The surfactant-rich phase was diluted with suitable solvent and was separated with using centrifugation, and then measurements were performed with a micro-injection flame atomic absorption spectrometry. Extraction conditions such as pH, amount of Ligand (Complexing Agent) and Surfactant, equilibrium temperature and time, diluent volume and type were optimized. Also ionic strength effect and limit of interferences were studied. Under the optimum conditions, the limit of detection (3Sb/m) of 0.2 µg L-1, an enhancement factor of 116 and the relative standard deviation (5 µg L-1, n=5) of 4.5% were obtained. The calibration curve was linear for the concentration range of 0.5 to 20 µg L-1 with correlation coefficient of 0.9992. The proposed method was applied to determination of cadmium ion in water samples including tap water, mineral water, river water and sea water also baby food samples including infant formula powder (milk-based) and infant cereal Powder (wheat and milk-based). 


2019 ◽  
Vol 697 ◽  
pp. 133861
Author(s):  
Jangwoo Lee ◽  
Young-Ah Ahn ◽  
Kyungho Choi ◽  
Jeongim Park ◽  
Hyo-Bang Moon ◽  
...  
Keyword(s):  

2017 ◽  
Vol 15 (2) ◽  
pp. 491-498 ◽  
Author(s):  
Esmail Vessally ◽  
Ebrahim Ghorbani-Kalhor ◽  
Rahim Hosseinzadeh-Khanmiri ◽  
Mirzaagha Babazadeh ◽  
Akram Hosseinian ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document