Data reduction in the ITMS system through a data acquisition model with self-adaptive sampling rate

2008 ◽  
Vol 83 (2-3) ◽  
pp. 358-362 ◽  
Author(s):  
M. Ruiz ◽  
JM. López ◽  
G. de Arcas ◽  
E. Barrera ◽  
R. Melendez ◽  
...  
2008 ◽  
Vol 79 (10) ◽  
pp. 10F336 ◽  
Author(s):  
G. de Arcas ◽  
J. M. López ◽  
M. Ruiz ◽  
E. Barrera ◽  
J. Vega ◽  
...  

2020 ◽  
Vol 14 (8) ◽  
pp. 969-976
Author(s):  
Ahmad Rivai ◽  
Nasrudin Abd Rahim ◽  
Mohamad Fathi Mohamad Elias ◽  
Jafferi Jamaludin

Author(s):  
Kota Yamamoto ◽  
Hisashi Asanuma ◽  
Hiroaki Takahashi ◽  
Takafumi Hirata

New data reduction method for isotopic measurements using high-gain Faraday amplifiers enables precise uranium isotopic analysis even from transient signals.


2018 ◽  
Vol 941 ◽  
pp. 2390-2394
Author(s):  
David Thomas Marehn ◽  
Detlef Wilhelm ◽  
Heike Pospisil ◽  
Roberto Pizzoferrato

Traceability has an enormous value for companies, but especially for those working in the regulated environment. It plays a special role in the field of pharmacy with respect to manufacturing, controlling and distributing batches of drugs. Through the guidance of Good Manufacturing Practice (GMP) traceability should be ensured. An increasing number of pharmaceutical companies are member of one of the global pharmacopoeias (United States Pharmacopeia, European Pharmacopeia and Japanese Pharmacopeia). The specifications of these pharmacopoeias describe the best practice in documentation, control, qualification and risk management. But however, the pharmacopoeias are written very generally and do not distinguish between the vendors of the analytical instruments. Here, we analyze how chromatographic analyses and data acquisition rely on a specific vendor of the device and the chromatography data system (CDS), the controlling software. We present a way to compare the data acquisition of different CDSs communicating with HPLC instruments. A newly developed software called Data Collector allows the acquisition of data from a HPLC detector parallel to the controlling CDS in the same run. Two HPLC systems and two different CDSs using a well defined sample standard have been tested. The direct comparison of the acquired data precludes unexpected data manipulations of both tested CDSs and shows that there are primarily deviations between the CDSs due to time variations only which depend on the sampling rate. All in all the Data Collector can be used for the traceability of data acquisition.


Sign in / Sign up

Export Citation Format

Share Document