scholarly journals Sa1450 YIELD OF PANCREATIC FINE-NEEDLE BIOPSY NOT AFFECTED BY PRIOR BILIARY STENT PLACEMENT

2020 ◽  
Vol 91 (6) ◽  
pp. AB196
Author(s):  
Roberto Trasolini ◽  
Natasha K. Klemm ◽  
David Farnell ◽  
Fergal Donnellan
2019 ◽  
Vol 07 (04) ◽  
pp. E545-E550 ◽  
Author(s):  
Muthuraman Alagappan ◽  
Natasha Darras ◽  
Lauren Yang ◽  
Paul Vanderlaan ◽  
Meir Mizrahi ◽  
...  

Abstract Background and study aims During evaluation of pancreaticobiliary strictures, it is common practice to send biliary stents for cytologic analysis. However, in recent years, complementary tissue acquisition techniques ranging from cholangioscopy to fine-needle biopsy have improved the ability to acquire tissue and diagnose malignancy. Data are limited on the current diagnostic yield and cost effectiveness of biliary stent analysis. Patients and methods We performed a retrospective study of all pancreaticobiliary stents sent for analysis in a tertiary care academic medical center from June 2013 to September 2016. Patient demographics, stent information, and final diagnosis history were collected through chart review. Costs were determined using published reimbursement rates for Medicare. Results Two hundred thirty-one stents from 175 patients were sent for cytologic analysis during the study period. Of the 62 stents obtained from patients ultimately diagnosed with malignancy, only one (1.6 %) had positive cytology for malignant cells, while the others were acellular/non-diagnostic (2/62, 3.2 %), negative (48/62, 77.4 %), or atypical (11/62, 17.7 %). The sensitivity of stent cytology for diagnosis of malignancy was 1.6 % (1/62). No cases were identified in which stent cytology changed clinical management. From a payer perspective, the mean estimated cost for each stent cytologic analysis is greater than $ 70.00. Conclusions While stent cytologic analysis is a common clinical practice, the diagnostic yield and cost effectiveness of the practice must be reevaluated. With the rise of newer diagnostic technologies such as digital cholangioscopy and endoscopic ultrasound-guided fine-needle biopsy, it may be time to “think lean” and acknowledge a sunset for biliary stent cytology.


2015 ◽  
Vol 54 (03) ◽  
pp. 101-105 ◽  
Author(s):  
F. A. Verburg

SummaryThyroid surgery is one of the more common surgical procedures in Germany. This is in contrast with the situation in some other countries, where this procedure is performed comparatively rarely. In this paper the number of thyroid surgeries in Germany is compared with other western countries (Netherlands, USA, England). In contrast to e. g. the USA and England the number of thyroid surgeries in Germany is declining, however with approximately 109/100 000/year in 2012 is still elevated (Netherlands: 16/100 000/year, USA: at least 42/100 000/year, England: at least 27/100 000/year).Possible contributing factors to this higher number of thyroid surgeries in Germany are explored. These factors include iodine deficiency, the frequent use of advanced diagnostics such as ultrasound, insufficient use of preoperative diagnostic measures such as fine needle biopsy and the practice of “defensive medicine”. How much each of these factors contributes is however unclear.


Sign in / Sign up

Export Citation Format

Share Document