scholarly journals Su1255 LARGER NEEDLE SIZE IS ASSOCIATED WITH IMPROVED SENSITIVITY, SPECIFICITY, AND ACCURACY IN THE DIAGNOSIS OF SOLID LESIONS: A RETROSPECTIVE ANALYSIS OF 22G VERSUS 25G FINE NEEDLE BIOPSY

2020 ◽  
Vol 91 (6) ◽  
pp. AB295-AB296
Author(s):  
Thomas R. McCarty ◽  
Diogo T. de Moura ◽  
Pichamol Jirapinyo ◽  
Marvin Ryou ◽  
Linda Lee ◽  
...  
2019 ◽  
Vol 07 (02) ◽  
pp. E189-E194 ◽  
Author(s):  
En-Ling Leung Ki ◽  
Anne-Isabelle Lemaistre ◽  
Fabien Fumex ◽  
Rodica Gincul ◽  
Christine Lefort ◽  
...  

Abstract Background and aims This study aimed to evaluate the performance of Macroscopic On-site Evaluation (MOSE) using a novel endoscopic ultrasound (EUS) fine needle biopsy (FNB) needle (22-G Franseen-tip needle, Acquire, Boston Scientific Incorporated, Boston, Massachusetts, United States), and without using Rapid On-Site Evaluation (ROSE). Method Between May 2016 and August 2016, all consecutive patients referred to our center for EUS tissue acquisition (TA) for solid lesions underwent EUS-FNB with the 22-G Franseen-tip needle unless contra-indicated. The operator performed MOSE. If no macroscopic core was visualized, a second pass was performed. The final diagnosis was defined as unequivocal histology from EUS-TA with compatible 18 months follow-up, surgical resection, or both. We retrospectively analyzed the performance of MOSE. Results A total of 46 consecutive patients was included, and 54 solid lesions were biopsied. The endosonographer visualized core tissue in 93 % (50/54) of targets with a single pass, of which the pathologist confirmed histologic core fragments in 94 % (47/50). Four lesions required two passes, and the overall correlation between MOSE and histologic core fragments was 94 % (48/51). Diagnostic adequacy was 98 % (53/54) with one biliary target biopsied without significant material. The overall diagnostic accuracy was 94 %. Sensitivity, specificity, positive predictive value, and negative predictive value for malignancy were 92 %, 100 %, 100 %, and 81 %, respectively. No adverse events were reported. Conclusion Our study demonstrated that MOSE using the 22-G Franseen-tip needle could limit needle passes by accurately estimating histologic core fragments. It also demonstrated that high diagnostic adequacy and accuracy of > 90 % could be achieved without ROSE.


2019 ◽  
Vol 89 (6) ◽  
pp. AB313-AB314
Author(s):  
Diogo T. de Moura ◽  
Galileu F. Farias ◽  
Pichamol Jirapinyo ◽  
Erik A. Holzwanger ◽  
Ahmad Najdat Bazarbashi ◽  
...  

2021 ◽  
Author(s):  
Gabriele Delconte ◽  
Federica Cavalcoli ◽  
Andrea Magarotto ◽  
Giovanni Centonze ◽  
Cristina Bezzio ◽  
...  

Introduction: Fine Needle Biopsy (FNB) has been suggested to provide better histological samples as compared to endoscopic ultrasound fine needle aspiration (EUS-FNA). However, studies comparing EUS-FNA and EUS-FNB for pancreatic lesions reported contrasting results. The aim of this study was to compare the clinical performance of EUS-FNA versus EUS-FNB with ProCore needle for the investigation of pancreatic lesions. Methods: We reviewed all patients undergoing EUS for the investigation of pancreatic lesions from August 2012 to September 2018. From August 2012 to January 2015 all procedures were performed with standard needles, whereas from February 2015 to September 2018 the use of ProCore needles had been introduced. Data on diagnostic accuracy, number of needle passes and/or adverse events were collected. Results: 324 patients were retrospectively evaluated: 190 (58.6%) underwent EUS-FNA and 134 (41.4%) EUS-FNB. Both EUS-FNA and EUS-FNB showed high diagnostic accuracy for malignancy [94% (CI 95%:89-97%) vs 94% (CI 95%:89-98%)]. Notable, there were no differences between EUS-FNA and EUS-FNB in terms of sensitivity, specificity, positive and negative likelihood ratio, histological core tissue retrieval, adverse events or number of needle passes. However, subgroup analysis noted a higher diagnostic accuracy for 25G EUS-FNB as compared to 25G EUS-FNA (85,7% vs 55,5%; *p=0.023). Conclusion: EUS-FNB with ProCore needle is safe and feasible in pancreatic lesions. ProCore needle did not provide any advantage in terms of diagnostic accuracy, sensitivity, specificity, positive and/or negative likelihood ratio, or acquisition of core specimen, therefore its routine application is not