Biliary stone formed around prolene suture material in the afferent loop causing acute cholangitis

Author(s):  
Zheng Ruhua ◽  
Lv Ying ◽  
Wang Lei ◽  
Zou Xiaoping
2020 ◽  
Vol 13 (1) ◽  
pp. e232498
Author(s):  
Fernando Azevedo ◽  
Carolina Canhoto ◽  
José Guilherme Tralhão ◽  
Hélder Carvalho

Afferent loop syndrome is a rare complication after gastrectomy with Billroth II or Roux-en-Y reconstruction, caused by an obstruction in the proximal loop. The biliary stasis and bacterial overgrowth secondary to this obstruction can lead to repeated episodes of acute cholangitis. We present the case of a male patient who had previously undergone gastrectomy with Roux-en-Y reconstruction and later experienced multiple episodes of acute cholangitis secondary to choledocolithiasis. He underwent an open exploration of the bile ducts with choledocolitotomy, but the events of cholangitis persisted. Further investigation permitted to identify a dilation of the biliary loop of the Roux-en-Y anastomosis, suggesting enterobiliary reflux as the cause of recurrent acute cholangitis. Therefore, a bowel enterectomy and new jejunojejunostomy were undertaken, and normal biliary flow was re-established. The surgical treatment is mandatory in benign causes, leading to the resolution of the obstruction and subsequent normalisation of bile flow.


Cases Journal ◽  
2009 ◽  
Vol 2 (1) ◽  
pp. 6339 ◽  
Author(s):  
John Spiliotis ◽  
Demetrios Karnabatidis ◽  
Archodoula Vaxevanidou ◽  
Anastasios C Datsis ◽  
Athanasios Rogdakis ◽  
...  

2021 ◽  
Vol 30 (8) ◽  
pp. 626-630
Author(s):  
Ezzatollah Rezaei ◽  
Hamed Farhadi ◽  
Saeedeh Hajebi Khaniki ◽  
Hamzeh Zarei ◽  
Yavar Shams Hojjati

Objective: The type of suture material affects the quality of scars. The aim of this study was to find the superior suture material for reduction mammoplasty between Prolene and Monocryl based on the comparison of scars. Method: A prospective observational study was conducted at a university-based hospital in Mashhad, Iran between October 2015 and September 2017. Monocryl and Prolene suture materials, used for closing the outermost layer in mammoplasty, were compared. Patients' incision scars were assessed objectively according to the Patient and Observer Scar Assessment (POSAS) criteria. The relevant CONSORT guideline was used for reporting this study. Results: Seventy-eight women with a mean age of 36.8±9.5 years were entered into the study. The frequency of wound healing in both groups was 97.4% 1 month after surgery and by the third visit, 3 months after surgery, only one patient had a stretched scar. Moreover, wound inflammation in the first two visits was less frequent in the Prolene group that healed completely 3 months after surgery (after excluding the one patient with wide scar inflammation). The frequency of itching of the wound in the Monocryl group was 24.4%, 11.5% and 12.8% in the three follow-up visits, respectively, and the values for the Prolene group were 24.4%, 9.0% and 6.4%, respectively. No significant difference was seen between the two groups in terms of wound healing, inflammation and itching (p>0.05). Overall, 94.8% of patients were satisfied with the surgery. Conclusions: Our study revealed that there was no significant difference between Monocryl and Prolene. Hence, either of the two suture materials can be used for wound closure in reduction mammoplasty.


2017 ◽  
Vol 25 (1) ◽  
pp. 28
Author(s):  
Saurabh Shrivastava ◽  
Priyanka Patkar ◽  
Reshma Ramakrishnan ◽  
Shruti Gajera

VASA ◽  
2015 ◽  
Vol 44 (6) ◽  
pp. 451-457 ◽  
Author(s):  
Vincenzo Gasbarro ◽  
Luca Traina ◽  
Francesco Mascoli ◽  
Vincenzo Coscia ◽  
Gianluca Buffone ◽  
...  

Abstract. Background: Absorbable sutures are not generally accepted by most vascular surgeons for the fear of breakage of the suture line and the risk of aneurysmal formation, except in cases of paediatric surgery or in case of infections. Aim of this study is to provide evidence of safety and efficacy of the use of absorbable suture materials in carotid surgery. Patients and methods: In an 11 year period, 1126 patients (659 male [58.5 %], 467 female [41.5 %], median age 72) underwent carotid endarterectomy for carotid stenosis by either conventional with primary closure (cCEA) or eversion (eCEA) techniques. Patients were randomised into two groups according to the type of suture material used. In Group A, absorbable suture material (polyglycolic acid) was used and in Group B non-absorbable suture material (polypropylene) was used. Primary end-point was to compare severe restenosis and aneurysmal formation rates between the two groups of patients. For statistical analysis only cases with a minimum period of follow-up of 12 months were considered. Results: A total of 868 surgical procedures were considered for data analysis. Median follow-up was 6 years (range 1-10 years). The rate of postoperative complications was better for group A for both cCEA and eCEA procedures: 3.5 % and 2.0 % for group A, respectively, and 11.8 % and 12.9 % for group B, respectively. Conclusions: In carotid surgery, the use of absorbable suture material seems to be safe and effective and with a general lower complications rate compared to the use of non-absorbable materials.


2019 ◽  
Author(s):  
J Rivory ◽  
F Rostain ◽  
JC Saurin ◽  
T Ponchon ◽  
A Lupu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document