scholarly journals 339 Evaluation of Left Ventricular Systolic Function Assessment by Standard Steady-state Free Precession Cardiac Magnetic Resonance Using Automatic Left Ventricular Ejection Fraction Assessment Software Compared to Manually Performed Assessment

2020 ◽  
Vol 29 ◽  
pp. S186
Author(s):  
R. Anstey ◽  
K. Guppy-Coles ◽  
J. Younger ◽  
A. Dahiya
2021 ◽  
Author(s):  
Pauline Yeung NG ◽  
Tammy Sin Kwan MA ◽  
April IP ◽  
Shu FANG ◽  
Andy Chak Cheung LI ◽  
...  

Abstract Background:Peripheral veno-arterial extracorporeal membrane oxygenation (V-A ECMO) is used to support circulatory failure refractory to conventional therapy. However, data on the heart-ECMO interaction at different levels of ECMO blood flow during the immediate period after ECMO initiation are sparse. We evaluated the effects of varying ECMO blood flow rate on left ventricular systolic function.Methods:Adult patients who were supported by peripheral V-A ECMO in a tertiary referral center were recruited. Serial hemodynamic and cardiac performance parameters were measured by transthoracic echocardiogram within the first 48 hours after implementation of V-A ECMO. Measurements at 100%, 120%, and 50% of target blood flow (TBF) were compared.Results:A total of 45 patients were included, 32 (71.1%) were male, and the median age was 57 (50-64) years. The main indications for V-A ECMO were myocardial infarction 25 (55.6%) and myocarditis 6 (13.3%). With a decrease in extracorporeal blood flow from 100% to 50% of TBF, mean arterial pressure dropped from 75±18 to 67±20 mmHg (p<0.001), but stroke volume increased from 15 (8-25) to 21 (13-34) mL (p<0.001), and cardiac index increased from 0.8 (0.5-1.3) to 1.2 (0.7-1.7) L/min/m2 (p<0.001). All indices of left ventricular contractility improved at 50% compared with 100% TBF: the global longitudinal strain improved from -2.8 (-5.4-0) to -4.7 (-8.2- -1.1)% (p<0.001); left ventricular ejection fraction increased from 16.8 (10.0-28.5) to 28.2 (18.0-35.5)% (p<0.001); and left ventricular outflow tract velocity time integral increased from 4.7 (2.7-7.8) to 7.7 (3.9-11.3) cm (p<0.001). The addition of echocardiographic parameters improved the discrimination of the SAVE score in predicting hospital mortality (AUROC 0.71 vs 0.58).Conclusions:In the initial period of V-A ECMO support, left ventricular systolic function quantified bedside echocardiography was inversely related to ECMO blood flow rate. The heart-ECMO interaction should be considered when determining goals of ECMO flow after initiation.


Cardiology ◽  
2015 ◽  
Vol 130 (2) ◽  
pp. 91-95
Author(s):  
Yang Liu ◽  
Manasi Bapat ◽  
Haroon Kamran ◽  
Louis Salciccioli ◽  
Anna Rozenboym ◽  
...  

Low ankle-brachial index (ABI) is a marker of peripheral arterial disease associated with higher cardiovascular risk. ABI has been found to be influenced by left ventricular ejection fraction (LVEF), but this relation is confounded by atherosclerosis. Objectives: Since nonhuman primates have a low incidence of atherosclerosis, we sought to evaluate the effect of LVEF on ABI in 24 healthy female bonnet macaques (age 83 ± 21 months). Methods: LVEF was determined by echocardiography during anesthesia with ketamine. ABI was determined using automatic blood pressure cuff. Results: Mean LVEF was 73 ± 6%. Mean ABI was 1.03 (range 0.78-1.17) with similar right and left lower limb values (p = 0.78). On univariate analysis, mean ABI was significantly correlated with LVEF (r = 0.58, p = 0.003) but not with age, crown-rump length or weight. Mean LVEF increased in a stepwise manner from lowest to highest ABI tertile (68 ± 6 vs. 73 ± 4 vs. 77 ± 5%, p = 0.008). On ordinal regression and forced multivariate linear analyses, ABI status was independently related to LVEF. Conclusions: ABI is influenced by left ventricular systolic function but not age, height, weight or mass index in bonnet macaques. Left ventricular systolic function should be accounted for when considering ABI measurements.


Sign in / Sign up

Export Citation Format

Share Document