The time course of paroxysmal atrial fibrillation and its implications: An analysis from a snapshot

2013 ◽  
Vol 168 (3) ◽  
pp. 2867-2868
Author(s):  
Yoshifusa Aizawa ◽  
Nobue Yagihara ◽  
Daisuke Izumki ◽  
Haruo Hanawa ◽  
Makoto Kodama ◽  
...  
EP Europace ◽  
1999 ◽  
Vol 1 (1) ◽  
pp. 40-42 ◽  
Author(s):  
A. M. Gillis

Abstract The Canadian Atrial Pacing Peri-Ablation for Paroxysmal Atrial Fibrillation Study tested the hypotheses that atrial pacing prevents paroxysmal atrial fibrillation (PAF) in patients without symptomatic bradycardia and that DDDR pacing is more likely to prevent PAF following total atrioventricular (AV) node ablation compared to VDD pacing. Patients with PAF who were refractory to or intolerant of antiarrhythmic drug therapy received a Medtronic Thera DR pacemaker 3 months prior to a planned total AV node ablation. Patients were randomized to atrial pacing or no pacing therapy. The time to first recurrence of sustained PAF was the primary study outcome event. Following AV node ablation, patients were randomized to the DDDR or VDD mode in a crossover study design. Patients were followed in each mode for 6 months. The time course of PAF recurrence was compared for each pacing mode.


2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
A Katbeh ◽  
K Iliodromitis ◽  
T De Potter ◽  
P Geelen ◽  
Z Balogh ◽  
...  

Abstract Background Radio-frequency catheter isolation of pulmonary veins (RF-PVI) is associated with changes of left atrial (LA) structure and function. However, there is limited knowledge regarding the long-term impact of successful RF-PVI on the LA mechanics. The aim of the current study was to assess the time course of LA performance in patients with paroxysmal atrial fibrillation (pAF) undergoing RF-PVI. Methods The study population included 24 consecutive patients (age:62 ± 21 years; 66% male) with symptomatic pAF and preserved left ventricular ejection fraction (≥50%) undergoing the first RF-PVI and 23 healthy controls. A comprehensive echocardiographic examination was performed one day before and 1 day, 3- and 12- months after RF-PVI. The reservoir, conduit and contractile LA strain (LAS), strain rate (LASR) and mechanical dispersion (LAMD) were assessed using two-dimensional speckle tracking echocardiography in apical views. Results At baseline, patients with pAF showed a significant reduction of all three components of LAS and LASR compared with controls (all p < 0.01). At 1 day after RF-PVI, LAS and LASR showed significant decrease compared with baseline (all p < 0.05) (figure). At 3-month follow up, LAS and LASR recovered to baseline values while LAMD showed a significant improvement (77ms vs 58ms, p = 0.003). At 12-month follow up, both reservoir and contractile LAS showed further improvement compared to 3-month values (31% vs 27%, and 15% vs 13%, both p < 0.05). Yet, even after 12 months, LAS values remained significantly lower compared with healthy controls (p < 0.05). LA emptying fraction was restored and LA end-systolic (max) and end-diastolic (min) volume index showed a significant decrease compared to baseline and 3-month values (all p < 0.05). Conclusion Successful RF-PVI is associated with acute decrease in LAS, followed by recovery to baseline values within 3 months and further improvement during one year. Reservoir and contractile LAS appears to be the most clinically useful indices to monitor LA performance in patients with pAF undergoing RF-PVI. Figure Time course of LA reservoir and contractile strain, LA max and min volume index, and LA mechanical dispersion (Baseline, 1-day FUP, 3- and 12-month FUP). Abstract 1039 Figure.


2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
A Katbeh ◽  
T De Potter ◽  
P Geelen ◽  
S Nagumo ◽  
Z Balogh ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Public Institution(s). Main funding source(s): International PhD Program in Cardiovascular Pathophysiology and Therapeutics CardioPaTh Background Radio-frequency catheter ablation (CA) is associated with changes of left atrial (LA) structure and function. However, there is limited knowledge regarding the long-term impact of successful CA on atrial morphology and mechanics. Purpose To compare the time course of LA and right atrial (RA) performance in patients with paroxysmal atrial fibrillation (AF) undergoing the first CA. Methods This prospective study included 89 consecutive patients (age:62 ± 21 years; 66% male) with a history of symptomatic AF who underwent successful CA. All patients maintained SR during follow-up. A comprehensive echocardiographic examination was performed 1- day before and 1-day, 3-month and 12-month after CA. The reservoir and contractile strain for both LA and RA (LAS, RAS), and left intra-atrial mechanical dispersion (LAMD) were assessed using 2D speckle tracking echocardiography in all three apical views (only 4CH view for RAS and LAMD). Results At baseline, all patients with paroxysmal AF showed a significant reduction of reservoir and contractile LAS and RAS compared with controls (all p < 0.01). CA was associated with a significant decrease in reservoir and contractile LAS while no significant difference was observed for RAS. At 3-month follow-up, the LAS showed full recovery, whereas the RAS did not show any significant change from 1-day post CA values. At 12-month follow-up, both reservoir and contractile LAS showed further improvement compared to baseline and 3-month values. LAMD derived from the LA strain curve followed a similar trend. Although the RA motion was not affected in the early phase, both reservoir and contractile RAS showed a significant increase between 3-month and 12-month follow-up. Conclusion Although the radio-frequency CA affected negatively LA performance in the acute phase, it has a long-term positive impact on both left and right atrial function. Figure Time course of reservoir and contractile LAS and RAS at Baseline, 1-day, 3-month and 12-month follow-up. Abstract Figure.


Sign in / Sign up

Export Citation Format

Share Document