Our experience in management of atrophic mandibular fractures: 2.0mm locking plate system versus 2.4mm locking plate system

2013 ◽  
Vol 42 (10) ◽  
pp. 1342
Author(s):  
V. Basile ◽  
R. Saez Vigo ◽  
G. Novelli ◽  
F. Mazzoleni ◽  
A. Bozzetti
2017 ◽  
Vol 28 (6) ◽  
pp. 1456-1461 ◽  
Author(s):  
Patiguli Wusiman ◽  
Julaiti Tuerxun ◽  
Buhiliqiemu Yaolidaxi ◽  
Adili Moming

2020 ◽  
Vol 10 (17) ◽  
pp. 5867
Author(s):  
Kerstin Radtke ◽  
Fabian Goede ◽  
Michael Schwarze ◽  
Peter Paes ◽  
Max Ettinger ◽  
...  

Proximal femoral varization osteotomy is a well-established surgical procedure in children with severe hip problems. This study aimed to evaluate the fixation stability and stiffness of two new implant systems. A biomechanical testing model was created with a total of 12 synthetic femora. Proximal femoral varization osteotomy was performed in every femur, and the synthetic femora were fixed with two different implant systems (PediLoc Locking Proximal Femur Plate System versus PediLoc Locking Cannulated Blade Plate System; OrthoPediatrics, Warsaw, IN, USA). The average torsional stiffness of the locking plate group was higher than for the cannulated blade plate group. Differences in internal and external rotations were seen between the two groups, but they were not significant. Using the tested implants in severe osteoporotic bones might show other results. Therefore, it might be helpful to use the locking plate system in osteoporotic bones and in cases of revision operations where stability is of critical focus.


2012 ◽  
Vol 5 (2) ◽  
pp. 91-96 ◽  
Author(s):  
Cassiano Costa Silva Pereira ◽  
Pâmela Letícia dos Santos ◽  
Ellen Cristina Gaetti Jardim ◽  
Idelmo Rangel Garcia Júnior ◽  
Elio Hitoshi Shinohara ◽  
...  

Maxillofacial trauma caused by firearms has considerably increased, in which the mandibular body is the site of highest incidence of firearm projectiles. In these cases, the use of titanium plates and screws allows the early restoration of form and function of the mandible with stable and predictable results. Recently, conventional plates have been extensively used to treat comminuted mandibular fractures. Nevertheless, the conventional system presents several limitations such as screw compression against the bone interface and the necessity of precise fit of plate to the bone. To overcome such drawbacks, the locking plates have emerged. The present clinical case reported the operative treatment of mandibular fracture caused by firearm projectiles with the use of locking plate. The indications, advantages, and disadvantages of this system are presented.


2015 ◽  
Vol 28 (04) ◽  
pp. 288-293 ◽  
Author(s):  
T. Nicetto ◽  
M. Petazzoni

SummaryObjectives: To describe the use of the Fixin locking plate system for stifle arthrodesis in dogs and to retrospectively report the clinical and radiographic outcomes in six cases.[uni2028]Materials and methods: Medical records of dogs that had arthrodesis with the Fixin locking plate system were reviewed. For each patient, data pertaining to signalment and implant used were recorded. Plate series and thickness, number of screws placed, number of cortices engaged, and screw diameters were also recorded. The outcome was determined from clinical and radiographic followups. Radiographic outcomes assessed included the measurement of the postoperative femoral-tibial angle in the sagittal plane.Results: Six dogs met the inclusion criteria for the study. Mean body weight was 13 kg (range: 3 - 34 kg). Radiographic follow-up (mean: 32 weeks, range: 3 - 52 weeks) was available for all dogs. In one case, an intra-operative complication occurred. In another case, a tibial fracture occurred 20 days after surgery. All arthrodeses healed and no implant complication was detected although all cases had mechanical lameness.Clinical significance: Stifle arthrodesis can be performed successfully using a Fixin locking plate system.


Sign in / Sign up