Transient and small signal stability improvement in microgrid using AWOALO with virtual synchronous generator control scheme

2020 ◽  
Vol 104 ◽  
pp. 233-244
Author(s):  
Thenpennaisivem Santhoshkumar ◽  
V. Senthilkumar
Author(s):  
Santhoshkumar Thenpennaisivem ◽  
V. Senthilkumar

In this article, a hybrid technique is proposed for improving the transient and small signal response in micro grid using virtual inertia. The proposed hybrid technique is the combined execution of both the emperor penguin optimizer (EPO) and butterfly optimization algorithm (BOA), and hence it is called EPOBOA technique. The major objective of the EPOBOA technique is to “optimize the control parameters to regulate the changes occurred in the grid parameter such as voltage and frequency based on the variations of inertia”. Here, the EPO is executed to modify the parameters of virtual synchronous generator units to achieve the objective function. The searching behaviour of the EPO is adapted by using the hunting behaviour of BOA. The proposed technique is executed in MATLAB/Simulink work site, and the experimental results are analyzed under three test cases: normal condition, irradiation change condition, and load change condition. The performance of the proposed technique is compared with different existing techniques and the calculated frequency deviation index of the proposed technique in all the cases is 0.0051, 0.0045, and 0.0047 and found to be very optimal compared with existing methods. Overall, the experimental outcomes show that the proposed EPOBOA method is more efficient and confirm its ability to solve the issues.


2006 ◽  
Vol 154 (2) ◽  
pp. 19-29 ◽  
Author(s):  
Kaoru Koyanagi ◽  
Daisuke Hiramatsu ◽  
Kaiichirou Hirayama ◽  
Yoichi Uemura

2019 ◽  
Author(s):  
Liang Lu ◽  
Ömer Göksu ◽  
Nicolaos Antonio Cutululis

This paper introduces a virtual synchronous machine (VSM) control scheme which is based on a minimized emulation of the model of a synchronous generator (SG) for a grid-forming wind turbine (WT) inverter. Based on this VSM control scheme, state-space representation and block diagram of the small-signal model for the VSM-controlled grid-forming inverter connected to an infinite bus are derived, which are used for small-signal stability analysis of the power angle in the VSM control scheme. This power angle small-signal stability (PAS) analysis is proposed as a simpler way for analyzing the influence on the rotor angle stability of power system from large share of VSM-controlled grid-forming inverters. Influence of parameters in the power loop of the control scheme on the PAS is investigated by analyzing the eigenvalue trajectories of the state matrix.


2014 ◽  
Vol 1003 ◽  
pp. 148-151
Author(s):  
Jian Chao Zhang ◽  
Xiao Rong Zhu ◽  
Wei Zhao

In order to study the small signal stability of power grid after grid-connection of large-scale Permanent Magnet Synchronous Generator (PMSG) wind farms, the mathematical model of PMSG was established. By means of simulation on a simple power system, the damping characteristics of grid under different wind power penetration and different access location of wind farms were studied in detail. Simulation results show that along with the increase of wind power, the inter-area oscillation mode damping would reduce. When wind farm was attached the receiving area, the inter-area oscillation mode damping was lower than it when wind farm was attached the supplying area.


2019 ◽  
Author(s):  
Liang Lu ◽  
Ömer Göksu ◽  
Nicolaos Antonio Cutululis

This paper introduces a virtual synchronous machine (VSM) control scheme which is based on a minimized emulation of the model of a synchronous generator (SG) for a grid-forming wind turbine (WT) inverter. Based on this VSM control scheme, state-space representation and block diagram of the small-signal model for the VSM-controlled grid-forming inverter connected to an infinite bus are derived, which are used for small-signal stability analysis of the power angle in the VSM control scheme. This power angle small-signal stability (PAS) analysis is proposed as a simpler way for analyzing the influence on the rotor angle stability of power system from large share of VSM-controlled grid-forming inverters. Influence of parameters in the power loop of the control scheme on the PAS is investigated by analyzing the eigenvalue trajectories of the state matrix.