scholarly journals TCT-312 Computational Modeling of Coronary Obstruction (CO) in Valve-in-Valve (ViV) Transcatheter Aortic Valve Replacement (TAVR): Comparison With Computed Tomography (CT)-Based Risk Assessment

2021 ◽  
Vol 78 (19) ◽  
pp. B127-B128
Author(s):  
Sri Krishna Sivakumar ◽  
Breandan Yeats ◽  
Venkateshwar Polsani ◽  
Pradeep Yadav ◽  
Vinod Thourani ◽  
...  
Author(s):  
Brian J. Forrestal ◽  
Brian C. Case ◽  
Charan Yerasi ◽  
Corey Shea ◽  
Rebecca Torguson ◽  
...  

Background: The supra-annular leaflet position and tall stent frame of the self-expanding Evolut PRO or Evolut PRO+ transcatheter heart valves (THVs) may cause coronary occlusion during transcatheter aortic valve replacement (TAVR)-in-TAVR and present challenges for future coronary access. We sought to evaluate the risk of TAVR-in-TAVR with Evolut PRO or Evolut PRO+ THVs and the feasibility of future coronary access. Methods: The CoreValve Evolut PRO Prospective Registry (EPROMPT; NCT03423459) prospectively enrolled patients with symptomatic severe aortic stenosis to undergo TAVR using a commercially available latest generation self-expanding THV at 2 centers in the United States. Computed tomography was performed 30 days after TAVR, which we used to simulate TAVR-in-TAVR with a second Evolut PRO or Evolut PRO+ THV and evaluate for risk of coronary obstruction and feasibility of future coronary access. Results: Eighty-one patients enrolled with interpretable computed tomography are reported herein. Computed tomography simulation predicted sinus of Valsalva sequestration and resultant coronary obstruction during future TAVR-in-TAVR in up to 23% of patients. Computed tomography simulation predicted that the position of the pinned THV leaflets would hinder future coronary access in up to 78% of patients after TAVR-in-TAVR. Conclusions: Further THV design improvements and leaflet modification strategies are needed to mitigate the risk of coronary obstruction during TAVR-in-TAVR with self-expanding THVs and to facilitate future coronary access. Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03423459.


2021 ◽  
Vol 14 (2) ◽  
pp. 211-220 ◽  
Author(s):  
Michel Pompeu B.O. Sá ◽  
Jef Van den Eynde ◽  
Matheus Simonato ◽  
Luiz Rafael P. Cavalcanti ◽  
Ilias P. Doulamis ◽  
...  

2021 ◽  
Vol 5 (5) ◽  
Author(s):  
Klaus-Dieter Hönemann ◽  
Steffen Hofmann ◽  
Frank Ritter ◽  
Gerold Mönnig

Abstract Background A rare, but serious, complication following transcatheter aortic valve replacement (TAVR) is the occurrence of an iatrogenic ventricular septal defect (VSD). Case summary We describe a case of an 80-year-old female who was referred with severe aortic stenosis for TAVR. Following thorough evaluation, the heart team consensus was to proceed with implantation via a transapical approach of an ACURATE neo M 25 mm valve (Boston Scientific, Natick, MA, USA). The valve was deployed harnessing transoesophageal echocardiographic (TOE) guidance under rapid pacing with post-dilation. Directly afterwards a very high VSD close to the aortic annulus was detected. As the patient was haemodynamically stable, the procedure was ended. The next day another TOE revealed a shunt volume (left-to-right ventricle) between 50% and 60%. Because the defect was partly located between the stent struts of the ACURATE valve decision was made to fix this leakage with implantation of a further valve and we chose an EVOLUT Pro 29 mm (Medtronic Inc., Minneapolis, MN, USA). The valve-in-valve was implanted 2–3 mm below the lower edge of the first valve, more towards the left ventricular outflow tract (LVOT) with excellent result: VSD was reduced to a very small residual shunt without any hemodynamic relevance. Discussion We suggest that an iatrogenic VSD located near the annulus may be treated percutaneously in a bail-out situation with implantation of a second valve that should be implanted slightly more into the LVOT to cover the VSD.