P1-393: THE INCREMENTAL VALUE OF AMYLOID PET VERSUS CSF BIOMARKERS FOR THE DIAGNOSIS OF ALZHEIMER'S DISEASE (INDIA-FBB STUDY)

2006 ◽  
Vol 14 (7S_Part_8) ◽  
pp. P452-P453
Author(s):  
Matteo Cotta Ramusino ◽  
Daniele Altomare ◽  
Frederic Assal ◽  
Aline Mendes ◽  
Alfredo Costa ◽  
...  
2006 ◽  
Vol 14 (7S_Part_1) ◽  
pp. P17-P18 ◽  
Author(s):  
Matteo Cotta Ramusino ◽  
Daniele Altomare ◽  
Frederic Assal ◽  
Aline Mendes ◽  
Alfredo Costa ◽  
...  

2019 ◽  
Vol 6 (9) ◽  
pp. 1815-1824 ◽  
Author(s):  
Daniel Alcolea ◽  
Jordi Pegueroles ◽  
Laia Muñoz ◽  
Valle Camacho ◽  
Diego López‐Mora ◽  
...  

2021 ◽  
Vol 39 (3) ◽  
pp. 214-218
Author(s):  
Min Hye Kim ◽  
Joonho Lee ◽  
Hong Nam Kim ◽  
In Ja Shin ◽  
Keun Lee ◽  
...  

We report a 61-year-old woman with clinical course for Alzheimer’s disease (AD) dementia and discordant amyloid-β positron-emission tomography (PET) and cerebrospinal fluid biomarkers. Brain magnetic resonance imaging revealed remarkable atrophy in the hippocampus. However, repeated delayed <sup>18</sup>F-flutemetamol brain amyloid PET images with 1 year-interval revealed no amyloid deposition, whereas her CSF revealed low Aβ42, high total tau and p-tau181. This discordant amyloid-β PET and CSF biomarkers in this early-onset AD dementia might be associated with her low resilience or mixed pathology.


Neurology ◽  
2021 ◽  
pp. 10.1212/WNL.0000000000012513
Author(s):  
Michel J. Grothe ◽  
Alexis Moscoso ◽  
Nicholas J. Ashton ◽  
Thomas K. Karikari ◽  
Juan Lantero-Rodriguez ◽  
...  

Objective:To study cerebrospinal fluid (CSF) biomarkers of Alzheimer’s disease (AD) analyzed by fully automated Elecsys immunoassays in comparison to neuropathologic gold standards, and compare their accuracy to plasma phosphorylated tau (p-tau181) measured using a novel Simoa method.Methods:We studied ante-mortem Elecsys-derived CSF biomarkers in 45 individuals who underwent standardized post-mortem assessments of AD and non-AD neuropathologic changes at autopsy. In a subset of 26 participants, we also analysed ante-mortem levels of plasma p-tau181 and neurofilament light (NfL). Reference biomarker values were obtained from 146 amyloid-PET-negative healthy controls (HC).Results:All CSF biomarkers clearly distinguished pathology-confirmed AD dementia (N=27) from HC (AUCs=0.86-1.00). CSF total-tau (t-tau), p-tau181, and their ratios with Aβ1-42, also accurately distinguished pathology-confirmed AD from non-AD dementia (N=8; AUCs=0.94-0.97). In pathology-specific analyses, intermediate-to-high Thal amyloid phases were best detected by CSF Aβ1-42 (AUC[95% CI]=0.91[0.81-1]), while intermediate-to-high CERAD neuritic plaques and Braak tau stages were best detected by CSF p-tau181 (AUC=0.89[0.79-0.99] and 0.88[0.77-0.99], respectively). Optimal Elecsys biomarker cut-offs were derived at 1097/229/19 pg/ml for Aβ1-42, t-tau, and p-tau181. In the plasma subsample, both plasma p-tau181 (AUC=0.91[0.86-0.96]) and NfL (AUC=0.93[0.87-0.99]) accurately distinguished pathology-confirmed AD (N=14) from HC. However, only p-tau181 distinguished AD from non-AD dementia cases (N=4; AUC=0.96[0.88-1.00]), and showed a similar, though weaker, pathologic specificity for neuritic plaques (AUC=0.75[0.52-0.98]) and Braak stage (AUC=0.71[0.44-0.98]) as CSF p-tau181.Conclusions:Elecsys-derived CSF biomarkers detect AD neuropathologic changes with very high discriminative accuracy in-vivo. Preliminary findings support the use of plasma p-tau181 as an easily accessible and scalable biomarker of AD pathology.Classification of Evidence:This study provides Class II evidence that fully-automated CSF t-tau and p-tau181measurements discriminate between autopsy-confirmed Alzheimer's disease and other dementias.


2019 ◽  
Vol 47 (2) ◽  
pp. 270-280 ◽  
Author(s):  
Matteo Cotta Ramusino ◽  
Valentina Garibotto ◽  
Ruggero Bacchin ◽  
Daniele Altomare ◽  
Alessandra Dodich ◽  
...  

2021 ◽  
pp. 1-12
Author(s):  
Luca Sacchi ◽  
Tiziana Carandini ◽  
Giorgio Giulio Fumagalli ◽  
Anna Margherita Pietroboni ◽  
Valeria Elisa Contarino ◽  
...  

Background: Association between cerebrospinal fluid (CSF)-amyloid-β (Aβ)42 and amyloid-PET measures is inconstant across the Alzheimer’s disease (AD) spectrum. However, they are considered interchangeable, along with Aβ 42/40 ratio, for defining ‘Alzheimer’s Disease pathologic change’ (A+). Objective: Herein, we further characterized the association between amyloid-PET and CSF biomarkers and tested their agreement in a cohort of AD spectrum patients. Methods: We include ed 23 patients who underwent amyloid-PET, MRI, and CSF analysis showing reduced levels of Aβ 42 within a 365-days interval. Thresholds used for dichotomization were: Aβ 42 <  640 pg/mL (Aβ 42+); pTau >  61 pg/mL (pTau+); and Aβ 42/40 <  0.069 (ADratio+). Amyloid-PET scans were visually assessed and processed by four pipelines (SPMCL, SPMAAL, FSGM, FSWC). Results: Different pipelines gave highly inter-correlated standardized uptake value ratios (SUVRs) (rho = 0.93–0.99). The most significant findings were: pTau positive correlation with SPMCL SUVR (rho = 0.56, p = 0.0063) and Aβ 42/40 negative correlation with SPMCL and SPMAAL SUVRs (rho = –0.56, p = 0.0058; rho = –0.52, p = 0.0117 respectively). No correlations between CSF-Aβ 42 and global SUVRs were observed. In subregion analysis, both pTau and Aβ 42/40 values significantly correlated with cingulate SUVRs from any pipeline (R2 = 0.55–0.59, p <  0.0083), with the strongest associations observed for the posterior/isthmus cingulate areas. However, only associations observed for Aβ 42/40 ratio were still significant in linear regression models. Moreover, combining pTau with Aβ 42 or using Aβ 42/40, instead of Aβ 42 alone, increased concordance with amyloid-PET status from 74% to 91% based on visual reads and from 78% to 96% based on Centiloids. Conclusion: We confirmed that, in the AD spectrum, amyloid-PET measures show a stronger association and a better agreement with CSF-Aβ 42/40 and secondarily pTau rather than Aβ 42 levels.


2021 ◽  
Author(s):  
Louise Emsell ◽  
Heleen Vanhaute ◽  
Kristof Vansteelandt ◽  
François-Laurent De Winter ◽  
Danny Christiaens ◽  
...  

AbstractOBJECTIVEMRI derived hippocampal volume (HV) and amyloid PET may be useful clinical biomarkers for differentiating between geriatric depression and Alzheimer’s Disease (AD). Here we investigated the incremental value of HV and 18F-flutemetmol PET in tandem and sequentially to improve discrimination in unclassified participants.METHODTwo approaches were compared in 41 participants with geriatric depression and 27 participants with probable AD: (1) amyloid and HV combined in one model and (2) HV first and then amyloid.RESULTSBoth HV(χ2(1) = 6.46: p= 0.011) and amyloid (χ2(1) =11.03: p=0.0009) were significant diagnostic predictors of depression (sensitivity: 95%, specificity: 89%). (2) 51% of participants were correctly classified according to clinical diagnosis based on HV alone, increasing to 87% when adding amyloid data (sensitivity: 94%, specificity: 78%).CONCLUSIONHippocampal volume may be a useful gatekeeper for identifying depressed individuals at risk for AD who would benefit from additional amyloid biomarkers when available.


2019 ◽  
Vol 11 (1) ◽  
Author(s):  
Maria João Leitão ◽  
Anuschka Silva-Spínola ◽  
Isabel Santana ◽  
Veronica Olmedo ◽  
Alicia Nadal ◽  
...  

Abstract Background Ongoing efforts within the Alzheimer’s disease (AD) field have focused on improving the intra- and inter-laboratory variability for cerebrospinal fluid (CSF) biomarkers. Fully automated assays offer the possibility to eliminate sample manipulation steps and are expected to contribute to this improvement. Recently, fully automated chemiluminescence enzyme immunoassays for the quantification of all four AD biomarkers in CSF became available. The aims of this study were to (i) evaluate the analytical performance of the Lumipulse G β-Amyloid 1-42 (restandardized to Certified Reference Materials), β-Amyloid 1-40, total Tau, and pTau 181 assays on the fully automated LUMIPULSE G600II; (ii) compare CSF biomarker results of the Lumipulse G assays with the established manual ELISA assays (INNOTEST®) from the same company (Fujirebio); and (iii) establish cut-off values and the clinical performance of the Lumipulse G assays for AD diagnosis. Methods Intra- and inter-assay variation was assessed in CSF samples with low, medium, and high concentrations of each parameter. Method comparison and clinical evaluation were performed on 40 neurological controls (NC) and 80 patients with a diagnosis of probable AD supported by a follow-up ≥ 3 years and/or positive amyloid PET imaging. A small validation cohort of 10 NC and 20 AD patients was also included to validate the cut-off values obtained on the training cohort. Results The maximal observed intra-assay and inter-assay coefficients of variation (CVs) were 3.25% and 5.50%, respectively. Method comparisons revealed correlation coefficients ranging from 0.89 (for Aβ40) to 0.98 (for t-Tau), with those for Aβ42 (0.93) and p-Tau (0.94) in-between. ROC curve analysis showed area under the curve values consistently above 0.85 for individual biomarkers other than Aβ40, and with the Aβ42/40, Aβ42/t-Tau, and Aβ42/p-Tau ratios outperforming Aβ42. Validation of the cut-off values in the independent cohort showed a sensitivity ranging from 75 to 95% and a specificity of 100%. The overall percentage of agreement between Lumipulse and INNOTEST was very high (> 87.5%). Conclusions The Lumipulse G assays show a very good analytical performance that makes them well-suited for CSF clinical routine measurements. The good clinical concordance between the Lumipulse G and INNOTEST assays facilitates the implementation of the new method in routine practice.


SLEEP ◽  
2019 ◽  
Vol 42 (6) ◽  
Author(s):  
Omonigho M Bubu ◽  
Elizabeth Pirraglia ◽  
Andreia G Andrade ◽  
Ram A Sharma ◽  
Sandra Gimenez-Badia ◽  
...  

Abstract Study Objectives To determine the effect of self-reported clinical diagnosis of obstructive sleep apnea (OSA) on longitudinal changes in brain amyloid PET and CSF biomarkers (Aβ42, T-tau, and P-tau) in cognitively normal (NL), mild cognitive impairment (MCI), and Alzheimer’s disease (AD) elderly. Methods Longitudinal study with mean follow-up time of 2.52 ± 0.51 years. Data were obtained from the Alzheimer’s Disease Neuroimaging Initiative (ADNI) database. Participants included 516 NL, 798 MCI, and 325 AD elderly. Main outcomes were annual rate of change in brain amyloid burden (i.e. longitudinal increases in florbetapir PET uptake or decreases in CSF Aβ42 levels); and tau protein aggregation (i.e. longitudinal increases in CSF total tau [T-tau] and phosphorylated tau [P-tau]). Adjusted multilevel mixed effects linear regression models with randomly varying intercepts and slopes was used to test whether the rate of biomarker change differed between participants with and without OSA. Results In NL and MCI groups, OSA+ subjects experienced faster annual increase in florbetapir uptake (B = .06, 95% CI = .02, .11 and B = .08, 95% CI = .05, .12, respectively) and decrease in CSF Aβ42 levels (B = −2.71, 95% CI = −3.11, −2.35 and B = −2.62, 95% CI = −3.23, −2.03, respectively); as well as increases in CSF T-tau (B = 3.68, 95% CI = 3.31, 4.07 and B = 2.21, 95% CI = 1.58, 2.86, respectively) and P-tau (B = 1.221, 95% CI = 1.02, 1.42 and B = 1.74, 95% CI = 1.22, 2.27, respectively); compared with OSA− participants. No significant variations in the biomarker changes over time were seen in the AD group. Conclusions In both NL and MCI, elderly, clinical interventions aimed to treat OSA are needed to test if OSA treatment may affect the progression of cognitive impairment due to AD.


2021 ◽  
Vol 11 (1) ◽  
pp. 47
Author(s):  
Giulia Giacomucci ◽  
Salvatore Mazzeo ◽  
Silvia Bagnoli ◽  
Matteo Casini ◽  
Sonia Padiglioni ◽  
...  

Background: The aims of this study were to compare the diagnostic accuracy, sensitivity, specificity, and positive and negative predictive values (PPV, NPV) of different cerebrospinal fluid (CSF) amyloid biomarkers and amyloid-Positron Emission Tomography (PET) in patients with a clinical diagnosis of Alzheimer’s disease (AD) and Frontotemporal Dementia (FTD); to compare concordance between biomarkers; and to provide an indication of their use and interpretation. Methods: We included 148 patients (95 AD and 53 FTD), who underwent clinical evaluation, neuropsychological assessment, and at least one amyloid biomarker (CSF analysis or amyloid-PET). Thirty-six patients underwent both analyses. One-hundred-thirteen patients underwent Apolipoprotein E (ApoE) genotyping. Results: Amyloid-PET presented higher diagnostic accuracy, sensitivity, and NPV than CSF Aβ1–42 but not Aβ42/40 ratio. Concordance between CSF biomarkers and amyloid-PET was higher in FTD patients compared to AD cases. None of the AD patients presented both negative Aβ biomarkers. Conclusions: CSF Aβ42/40 ratio significantly increased the diagnostic accuracy of CSF biomarkers. On the basis of our current and previous data, we suggest a flowchart to guide the use of biomarkers according to clinical suspicion: due to the high PPV of both amyloid-PET and CSF analysis including Aβ42/40, in cases of concordance between at least one biomarker and clinical diagnosis, performance of the other analysis could be avoided. A combination of both biomarkers should be performed to better characterize unclear cases. If the two amyloid biomarkers are both negative, an underlying AD pathology can most probably be excluded.


Sign in / Sign up

Export Citation Format

Share Document