The effect of magnetic susceptibility and magnetic field strength on porosity estimates determined from low-field nuclear magnetic resonance

2020 ◽  
Vol 179 ◽  
pp. 104096
Author(s):  
Kristina Keating ◽  
David O. Walsh ◽  
Elliot Grunewald
2020 ◽  
Vol 10 (11) ◽  
pp. 3745
Author(s):  
Yiqiu Tan ◽  
Danfeng Zhou ◽  
Mengxiao Song ◽  
Jie Li

Residual magnetic interference induced by applied magnetic field pulses inside a conductive shielded room (SR) has been a common issue in ultra-low-field (ULF) nuclear magnetic resonance (NMR). The rapid cutoff of the applied pre-polarizing field (Bp) induces eddy currents in the walls of the SR, which produces a decaying residual magnetic interference that may cause severe image distortions and signal loss. In this study, a pair of cancellation coils (CC) and control electronics were designed for the suppression of the residual magnetic interference in a SR. Simulations show that this method was effective in suppressing the residual magnetic field (Br) after removal of the pre-polarizing magnetic field. Then, a small-scale SR was designed and the effectiveness of this cancellation scheme was experimentally verified. The test results showed a good agreement with the simulation, which indicated that the cancellation scheme was capable of reducing Br field to a much lower level. The scheme proposed in this study provides a solution for suppressing the residual magnetic field in the ULF NMR system. After decoupling the eddy–current field, the effect of the suppression may be further improved by optimization of the cancellation coil in further work.


Author(s):  
Alexander I. Zhernovoy ◽  
◽  
Ilya A. Yakimenko ◽  

The magnetic liquid magnetization is usually determined by measuring the magnetic field strength, which linearly depends on the effective field constant of the liquid and the demagnetization coefficient of the sample. The article proposes to measure the magnetic field strength, generated by the same magnetic liquid in the samples of different shapes, and to determine the magnetization relying on the difference in strength, generated by the samples of various shapes, taking advantage of the fact that the effective field constant does not depend on the shape of the sample


AIP Advances ◽  
2018 ◽  
Vol 8 (5) ◽  
pp. 056814 ◽  
Author(s):  
Neelam Prabhu Gaunkar ◽  
Jayaprakash Selvaraj ◽  
Wei-Shen Theh ◽  
Robert Weber ◽  
Mani Mina

Author(s):  
Paul C. Lauterbur

Nuclear magnetic resonance imaging can reach microscopic resolution, as was noted many years ago, but the first serious attempt to explore the limits of the possibilities was made by Hedges. Resolution is ultimately limited under most circumstances by the signal-to-noise ratio, which is greater for small radio receiver coils, high magnetic fields and long observation times. The strongest signals in biological applications are obtained from water protons; for the usual magnetic fields used in NMR experiments (2-14 tesla), receiver coils of one to several millimeters in diameter, and observation times of a number of minutes, the volume resolution will be limited to a few hundred or thousand cubic micrometers. The proportions of voxels may be freely chosen within wide limits by varying the details of the imaging procedure. For isotropic resolution, therefore, objects of the order of (10μm) may be distinguished.Because the spatial coordinates are encoded by magnetic field gradients, the NMR resonance frequency differences, which determine the potential spatial resolution, may be made very large. As noted above, however, the corresponding volumes may become too small to give useful signal-to-noise ratios. In the presence of magnetic field gradients there will also be a loss of signal strength and resolution because molecular diffusion causes the coherence of the NMR signal to decay more rapidly than it otherwise would. This phenomenon is especially important in microscopic imaging.


Sign in / Sign up

Export Citation Format

Share Document