scholarly journals Will High-Sensitivity Troponin Improve the Evaluation of Patients With Chest Pain in the Emergency Department?

2013 ◽  
Vol 6 (1) ◽  
pp. 83-85 ◽  
Author(s):  
Todd D. Miller ◽  
Kent R. Bailey
BMJ Open ◽  
2018 ◽  
Vol 8 (10) ◽  
pp. e025339 ◽  
Author(s):  
Edward Carlton ◽  
Sarah Campbell ◽  
Jenny Ingram ◽  
Rebecca Kandiyali ◽  
Hazel Taylor ◽  
...  

IntroductionObservational data suggest a single high-sensitivity troponin blood test taken at emergency department (ED) presentation could be used to rule out major adverse cardiac events (MACE) in 10%–60% of ED patients with chest pain. This is done using an ‘undetectable’ cut-off (the Limit of Detection: LoD). We combined the LoD cut-off with ECG findings to create the LoDED strategy. We aim to establish whether the LoDED strategy works under real-life conditions, when compared with existing strategies, in a way that is cost-effective and acceptable to patients.Methods and analysisThis is a parallel-group pragmatic randomised controlled trial across UK EDs. Adults presenting to ED with suspected cardiac chest pain will be randomised 1:1. Existing rule-out strategies in current use across study centres, using serial high-sensitivity troponin testing, will be compared with the LoDED strategy. The primary outcome is successful early discharge (discharge from hospital within 4 hours of arrival) without MACE occurring within 30 days. Secondary outcomes include initial length of hospital stay; comparative costs; patient satisfaction and acceptability to patients. To detect a 9% difference between the early discharge rates (assuming an 8% rate in the standard care group) with 90% power, 594 patients need to be recruited, assuming a 95% follow-up rate.Ethics and disseminationThe study has been approved by the Frenchay Research Ethics Committee (reference 18/SW/0038). Results will be published in an international peer-reviewed journal. Lay summaries will be made available to patients.Trial registration numberISRCTN86184521; Pre-results.


CJEM ◽  
2020 ◽  
Vol 22 (1) ◽  
pp. 14-18
Author(s):  
Andrew D. McRae ◽  
James E. Andruchow ◽  
Frank X. Scheuermeyer ◽  
Jim Christenson ◽  
Paul Atkinson

2019 ◽  
Vol 73 (9) ◽  
pp. 202
Author(s):  
Joseph Gibbs ◽  
W. Frank Peacock ◽  
Simon Mahler ◽  
Richard Nowak ◽  
Christopher DeFilippi ◽  
...  

CJEM ◽  
2017 ◽  
Vol 19 (S1) ◽  
pp. S61-S62 ◽  
Author(s):  
J. Andruchow ◽  
A. McRae ◽  
T. Abedin ◽  
D. Wang ◽  
G. Innes ◽  
...  

Introduction: The HEART score is a validated tool created to risk stratify emergency department (ED) chest pain patients using 5 simple criteria (History, ECG findings, Age, Risk factors, and Troponin). Several studies have demonstrated the superiority of HEART over other well known risk stratification tools in identifying low risk chest pain patients suitable for early discharge. All but one of these studies used conventional troponin assays, and most were conducted in European populations. This study aims to validate the HEART score using a high-sensitivity troponin T assay in a Canadian population. Methods: This prospective cohort study was conducted at a single urban tertiary centre and regional percutaneous coronary intervention site in Calgary, Alberta. Patients were eligible for enrolment if they presented to the ED with chest pain, were age 25-years or older and required biomarker testing to rule out AMI at the discretion of the attending emergency physician. Patients were excluded if they had clear acute ischemic ECG changes, new arrhythmia or renal failure requiring hemodialysis. Clinical data were recorded by the emergency physician at the time of enrolment and outcomes were obtained from administrative data. High-sensitivity troponin-T (Roche Elecsys hs-cTnT) results were obtained in all patients at presentation. The primary outcome was AMI within 30-days of ED visit, the secondary outcome was 30-day major adverse cardiac events (MACE). Results: A total of 984 ED patients with complete HEART scores were enrolled from August 2014 to September 2016. The 30-day incidence of AMI and MACE in the overall population was 3.3% and 20.6%, respectively. HEART scores were predictive of 30-day AMI incidence: low risk (0-3): 0.77% (95%CI 0.0-1.5%), moderate risk (4-6): 4.3% (95%CI 2.3-6.2%) and high risk (7-10): 12.2% (95%CI 5.5-19.0%). HEART scores also predicted 30-day MACE: low risk (0-3): 5.0% (95%CI 3.1-6.9%), moderate risk (4-6): 31.8% (95%CI 27.2-36.4%) and high-risk (7-10): 61.4% (95%CI 51.2-71.5%). More than half of patients, 522 (53.0%) could be identified as low risk based on the HEART score using a single troponin result. Conclusion: Using a single high-sensitivity troponin result collected at ED presentation, the HEART score can rapidly and effectively identify more than half of ED chest pain patients as low risk for 30-day AMI, but is less sensitive for 30-day MACE.


2019 ◽  
Vol 18 (1) ◽  
pp. 1-4 ◽  
Author(s):  
Christopher W. Baugh ◽  
Benjamin M. Scirica ◽  
James L. Januzzi ◽  
David A. Morrow ◽  
Kent B. Lewandrowski ◽  
...  

CJEM ◽  
2018 ◽  
Vol 20 (S1) ◽  
pp. S28-S28
Author(s):  
A. D. McRae ◽  
S. Vatanpour ◽  
J. Ji ◽  
H. Yang ◽  
D. Southern ◽  
...  

Introduction: Patients with chronic kidney disease (CKD) are at high risk of cardiovascular events, and have worse outcomes following acute myocardial infarction (AMI). Cardiac troponin is often elevated in CKD, making the diagnosis of AMI challenging in this population. We sought to quantify test characteristics for AMI of a high-sensitivity troponin T (hsTnT) assay performed at emergency department (ED) arrival in CKD patients with chest pain, and to derive rule-out cutoffs specific to patient subgroups stratified by estimated glomerular filtration rate (eGFR). We also quantified the sensitivity and classification performance of the assays limit of detection (5 ng/L) and the FDA-approved limit of quantitation (6 ng/L) for ruling out AMI at ED arrival. Methods: Consecutive patients in four urban EDs from the 2013 calendar year with suspected cardiac chest pain who had a Roche Elecsys hsTnT assay performed on arrival were included f. This analysis was restricted to patients with an eGFR< 60 ml/min/1.73m2. The primary outcome was 7-day AMI. Secondary outcomes included major adverse cardiac events (death, AMI and revascularization). Test characteristics were calculated and ROC curves were generated for eGFR subgroups. Results: 1416 patients were included. 7-day AMI incidence was 10.1%. 73% of patients had an initial hsTnT concentration greater than the assays 99th percentile (14 ng/L). TCurrently accepted cutoffs to rule out MI at ED arrival ( 5 ng/L and 6 ng/L) had 100% sensitivity for AMI, but no patients with an eGFR less than 30 ml/min/1.73M had hsTnT concentrations below these thresholds. We derived eGFR-adjusted cutoffs to rule out MI with sensitivity >98% at ED arrival, which were able to rule out 6-42% of patients, depending on eGFR category. The proportion of patients able to be accurately ruled-in with a single hsTnT assay was substantially lower among patients with an eGFR <30 ml/min/1.73m2 (6-20% vs 25-43%). We also derived eGFR-adjusted cutoffs to rule-in AMI with specificity >90%, which accurately ruled-in up to 18% of patients. Conclusion: Cutoffs achieving acceptable diagnostic performance for AMI using single hsTnT sampling on ED arrival may have limited clinical utility, particularly among patients with very low eGFR. The ideal diagnostic strategy for AMI in patients with CKD likely involves serial high-sensitivity troponin testing with diagnostic thresholds customized to different eGFR categories.


Sign in / Sign up

Export Citation Format

Share Document