Chronoamperometric determination of diffusion coefficients of ferrocene in ionic liquids mixed with CO2 at high pressures

2010 ◽  
Vol 639 (1-2) ◽  
pp. 109-115 ◽  
Author(s):  
YanLi Guo ◽  
Mitsuhiro Kanakubo ◽  
Daisuke Kodama ◽  
Hiroshi Nanjo
2021 ◽  
Author(s):  
Yibo Yang ◽  
Teresa Regueira ◽  
Hilario Martin Rodriguez ◽  
Alexander Shapiro ◽  
Erling Halfdan Stenby ◽  
...  

Abstract Molecular diffusion plays a critical role in gas injection in tight reservoirs such as liquid-rich shale. Despite recent efforts on measuring diffusion coefficients at high pressures, there is a general lack of the diffusion coefficients in live oil systems at reservoir conditions relevant to the development of these tight reservoirs. The reported diffusion coefficients often differ in orders of magnitude, and there is no consensus on the reliability of the common correlations for liquid phase diffusion coefficients, such as the extended Sigmund correlation. We employed the constant volume diffusion method to measure the high-pressure diffusion coefficients in a newly designed high-pressure tube. The experimental method was first validated using methane + hexadecane and methane + decane, and then used to measure the methane diffusion coefficients in two live oils at reservoir conditions. The obtained data were processed by compositional simulation to determine the diffusion coefficients. The diffusion coefficients measured for methane + hexadecane and methane + decane are in agreement with the existing literature data. For methane + live oil systems, however, the diffusion coefficients estimated by the extended Sigmund correlation are much lower than the measured results. An over ten times adjustment is needed to best fit the pressure decay curves. A further check reveals that for live oil systems, the reduced densities are often in the extrapolated region of the original Sigmund model. The curve in this region of the extended Sigmund correlation has a weak experimental basis, which may be the reason for its large deviation. The estimates from other correlations like Wilke-Chang and Hayduk-Minhas also give very different results. We compared the diffusion coefficients in high-pressure oils reported in the literature, showing a large variation in the reported values. All these indicate the necessity for further study on accurate determination of high-pressure diffusion coefficients in live oils of relevance to shale and other tight reservoirs.


2019 ◽  
Vol 70 (11) ◽  
pp. 3903-3907
Author(s):  
Galina Marusic ◽  
Valeriu Panaitescu

The paper deals with the issues related to the pollution of aquatic ecosystems. The influence of turbulence on the transport and dispersion of pollutants in the mentioned systems, as well as the calculation of the turbulent diffusion coefficients are studied. A case study on the determination of turbulent diffusion coefficients for some sectors of the Prut River is presented. A new method is proposed for the determination of the turbulent diffusion coefficients in the pollutant transport equation for specific sectors of a river, according to the associated number of P�clet, calculated for each specific area: the left bank, the right bank and the middle of the river.


2020 ◽  
Vol 16 (5) ◽  
pp. 652-659
Author(s):  
Asiye A. Avan ◽  
Hayati Filik

Background: An Ionic Liquid-based based Dispersive Liquid-Liquid Microextraction (IL-DLLME) method was not applied to preconcentration and determination of bilirubin. Ionic Liquids (ILs) are new chemical compounds. In recent years, Ionic Liquids (ILs) have been employed as alternative solvents to toxic organic solvents. Due to these perfect properties, ILs have already been applied in many analytical extraction processes, presenting high extraction yield and selectivity for analytes. Methods: In this study, IL-DLLME was applied to biological samples (urine and serum) for the spectrophotometric detection of bilirubin. For bilirubin analysis, the full-color development was based on the reaction with periodate in the presence of hydrochloric acid. The high affinity of bilirubin for the ionic liquid phase gave extraction percentages above 98% in 0.3 M HCl solution. Results: Several IL-extraction parameters were optimized and room temperature ionic liquid 1-butyl- 1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide and ethanol were used as extraction and disperser solution. The linear range was found in the range of 0.5-6.0 μM (0.3-3.5 μg mL-1) and the limits of detection of the proposed method was 0.5 μM (0.3 μg mL-1). The proposed method was applied for the preconcentration and separation of trace bilirubin in real urine samples. Also, the recoveries for bilirubin in spiked biological samples (urine and serum) were found to be acceptable, between 95-102%. Conclusion: The proposed IL-DLLMEapproach was employed for the enrichment and determination of trace levels of bilirubin in urine samples using NaIO4 as an oxidizing agent and Uv-vis spectrophotometric detection. The periodate oxidation of bilirubin is rapid, effective, selective, and simple to perform. The method contains only HCl, NaOI4, and an anionic surfactant. The method may be useful for economizing in the consumption of reagents in bilirubin determining. The IL-DLLMEmethod ensures a high yield and has a low toxicity no skin sensitization, no mutagenicity and no ecotoxicity in an aquatic environment since only very low quantities of an IL is required. For full-color formation, no any extra auxiliary reagents are required. Besides, the IL-DLLME technique uses a low-cost instrument such as Uv-vis which is present in most of the medical laboratories.


Author(s):  
Silvana M. Álvarez ◽  
Natalia E. Llamas ◽  
Mónica B. Álvarez ◽  
Jorge E. Marcovecchio ◽  
Mariano Garrido ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document