Cloud point extraction with/without chelating agent on-line coupled with inductively coupled plasma optical emission spectrometry for the determination of trace rare earth elements in biological samples

2010 ◽  
Vol 174 (1-3) ◽  
pp. 534-540 ◽  
Author(s):  
Yingjie Li ◽  
Bin Hu
Author(s):  
Masoud Aghahoseini ◽  
Gholamhassan Azimi ◽  
M. K. Amini

Determination of traces of Cd, Co, Cu, Mn and Pb elements in zirconium and its alloys by inductively coupled plasma optical emission spectrometry (ICP OES) suffers from severe spectral interferences...


2013 ◽  
Vol 69 (2) ◽  
pp. 312-319 ◽  
Author(s):  
Cennet Karadaş ◽  
Derya Kara

A new method has been developed for the determination of rare earth elements (REEs) (Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu) in water samples based on preconcentration with a mini-column packed with 6-(2-thienyl)-2-pyridinecarboxaldehyde functionalized Amberlite XAD-4 resin prior to their determination using inductively coupled plasma optical emission spectrometry (ICP-OES). The optimum experimental parameters for preconcentration of REEs, such as pH of the sample, sample and eluent flow rates and sample volume, were investigated. The optimum pH values for quantitative (90–110%) sorption of the REE ions were between 6.0 and 8.0. The elution process was carried out using 2 mL of 1.0 mol L–1 HNO3 solution. Under the optimum conditions, detection limits between 0.032 and 0.963 μg L−1 for a 10 mL sample volume and 0.006 and 0.193 μg L−1 for a 50 mL sample volume were determined. The proposed method was successfully applied to the determination of REEs in water samples with recoveries in the range of 90.1–110.5%.