Replacement of an Extruded Segment of Radius after Autoclaving and Sterilising with Gentamicin

2006 ◽  
Vol 31 (6) ◽  
pp. 616-618 ◽  
Author(s):  
P. KUMAR ◽  
D. SHRESTHA ◽  
S. BAJRACHARYA

A 10 year-old boy had a traumatic extrusion of 10 cm of the distal radius. The segment of bone was replaced after washing it with providine iodine solution and normal saline, autoclaving and dipping in gentamicin solution for 2 hour. At four and half year’s follow-up, there was complete incorporation of the segment with almost full functional recovery. We report this case for its rarity and discuss the treatment.

Hand ◽  
2021 ◽  
pp. 155894472199973
Author(s):  
Nicholas Munaretto ◽  
Adam Tagliero ◽  
Raahil Patel ◽  
Peter C. Rhee

Background Little information exists to guide decision-making with regard to distal radius fractures in the setting of ipsilateral hemiparesis or hemiplegia. Methods Patients who sustained a distal radius fracture in the setting of ipsilateral hemiparesis or hemiplegia secondary to brain injury were evaluated. Investigated variables included perioperative pain, preinjury House functional classification score, length of immobilization, radiographic outcome measurements, and time to union. Results There were 15 patients with distal radius fractures with a mean age of 65.9 years. The mean clinical and radiographic follow-up was 2.8 and 2.9 years, respectively. Wrists were placed into the nonoperative group (NOG, n = 10) and operative group (OG, n = 5). Pain significantly decreased at final follow-up for both groups. Baseline House functional classification scores averaged 1.3 and 1.6 for the NOG and OG, respectively, and were maintained at final follow-up. Length of immobilization for the NOG was 46 days and OG was 37 days, P = .15. Radiographic outcomes at final follow-up in the NOG and OG, respectively, were a mean radial height of 9.3 versus. 11.6 mm, radial inclination of 18.3° versus 22.3°, 4.2° dorsal tilt versus 5.3° volar tilt, and tear drop angle of 45.6° versus 44.5°. There were no significant differences in these measurements. Time to radiographic union averaged 58 days for the NOG and 67 days for the OG, P = .42. There were no revision surgeries. Conclusions Based on this small case series, patients with distal radius fracture and ipsilateral hemiparesis or hemiplegia may have similar clinical, functional, and radiographic outcomes, regardless of nonoperative or operative treatment.


Hand ◽  
2021 ◽  
pp. 155894472110289
Author(s):  
Anthony L. Logli ◽  
Marco Rizzo

Background: Owing to the many unique disease characteristics of Parkinson disease (PD)—namely resting tremors, muscular rigidity, and poor bone quality—we hypothesized that this patient population would have inferior outcomes with surgical management of acute distal radius fractures (DRFs) compared with the literature available on the general population. Methods: This is a retrospective observational study performed at a single, level 1, academic center from 2001 to 2020 capturing all adult patients with an isolated, acute, and closed DRF that ultimately underwent operative treatment. International Classification of Diseases 10 codes were used to identify 30 patients for manual chart review. Several patient and fracture characteristics were accounted for and complications, reoperations, and failures of surgical intervention were recorded. Results: There was a total of 7/30 failures (23%), 6/30 reoperations (20%), and 12 complications in 9/30 wrists (complication rate, 30%) at a mean latest follow-up of 11 months (1.2-158 months). Of the 7 failures, 5 were due to loss of reduction, and 2 of them were deep infections with mean time to failure of 8.3 weeks (range, 11 days-5.2 months). Conclusions: This study found a high rate of complications, reoperations, and early failure despite a short follow-up period and a small cohort of patients with PD treated surgically for a DRF. We recommend locked plating if suitable for the fracture type and early involvement of a multidisciplinary team to assist with medical optimization of PD to increase chances of a successful outcome.


2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
J Mulrain ◽  
K Joshi ◽  
F Doyle ◽  
A Abdulkarim

Abstract Introduction Distal radius fractures are common and trends for fixation have changed with increased use of volar locking plates in recent time. A meta-analysis will summarise the best evidence for treatment. Method A systematic review was conducted using PRISMA methodology to identify studies that reported clinical and/or radiological outcomes in patients with AO type C distal radius fractures when treated with external fixation versus ORIF. Results 10 randomised trials were included in this review, reporting on 967 patients. Clinical outcomes are in favour of volar plating at 3 months post-operation, but no difference between the two groups is seen at 6 or 12 months. Analysis of complication rates shows a minute increase in risk-ratio for volar plating versus external fixation. Subgroup analysis showed significantly higher re-operations after plate fixation and significantly higher infection after external fixation. Conclusions Internal fixation of complex distal radius fractures confers an improved clinical outcome at early follow up only and a minimally increased risk of complications. The improved grip strength with volar plating is only superior at early follow up and no long-term superiority is seen with either intervention. The type of surgery in this injury type therefore remains at the surgeon’s consideration on a case-by-case basis.


2014 ◽  
Vol 15 (1) ◽  
Author(s):  
Paul Ruckenstuhl ◽  
Gerwin A Bernhardt ◽  
Patrick Sadoghi ◽  
Mathias Glehr ◽  
Lukas A Holzer ◽  
...  

Author(s):  
Moritz Sharabianlou ◽  
Prerna Arora ◽  
Derek Amanatullah

This study aims to establish the midterm safety and performance for the direct superior approach to minimally invasive surgery total hip arthroplasty (MIS-THA). We used a unicentric, single-surgeon, retrospective, consecutive case series analysis of the first 40 patients who received primary unilateral direct superior MIS-THA. Special attention was given to functional recovery by measuring Harris Hip Score (HHS) and timed-up-and-go (TUG) with a mean follow up of 2.2 ± 0.4 years. A radiologic evaluation was performed. HHS and TUG improved significantly at three months and one year (p < 0.001). All components were placed within the Lewinnek safe zone with no change position or signs of loosening at two years. With a minimum of two years of follow up, the direct superior approach appears to be safe without any obvious or consistent postoperative complications—clinically or radiographically—with excellent functional recovery. Additionally, our subgroup analysis supported no late learning curve effect.


1973 ◽  
Vol 18 (1) ◽  
pp. 47-53 ◽  
Author(s):  
J. Trevor Silverstone ◽  
M.R. Salkind

The present study was undertaken to compare intravenous methohexitone, given as an adjunct to the behaviour therapy of phobias, with another centrally-acting, rapidly metabolised intravenous agent, propanidid, and also with normal saline. Thirty-five patients were included in the trial, all of whom had had phobic symptoms of at least one year's duration which were seriously interfering with their lives — 15 had specific phobias, 9 had social phobias and 11 had agoraphobia. Treatment consisted of twelve weekly drug-assisted desensitization treatments, using either 1 per cent methohexitone, 2.5 per cent propanidid or normal saline. Within each diagnostic group the drugs were randomly allocated. All treatments were conducted by one of the authors and all assessments by the other (who did not know which of the three preparations the patient had received). In addition to monthly ratings of the phobic symptoms, assessments of anxiety and depression were made, using self-rating scales. Patients were followed up six months after the end of treatment. Patients with specific phobias fared best, 9 out of the 13 who completed being considered to be markedly improved. Although the numbers are small there was a suggestion that patients receiving the two active drugs did better than those on the placebo. While methohexitone and propanidid were similarly effective, recovery time was much more rapid with propanidid. No patient in the specific phobia group relapsed significantly during the six months follow-up period. Furthermore, as the phobia improved the general anxiety level fell. Few depressive symptoms arose during successful desensitization, and there was no evidence of symptom substitution. Patients with social phobias and agoraphobia did far less well. In neither case did the active drugs appear to possess any advantage over placebo. Furthermore, of the 7 patients with agoraphobia who had improved, 4 relapsed within six months. It was concluded that drug-assisted desensitization is likely to be of greatest benefit in the management of specific phobias, with propanidid being the drug of choice.


2017 ◽  
Vol 137 (9) ◽  
pp. 1187-1191 ◽  
Author(s):  
N. L. Weil ◽  
M. El Moumni ◽  
S. M. Rubinstein ◽  
P. Krijnen ◽  
M. F. Termaat ◽  
...  

2020 ◽  
Vol 09 (03) ◽  
pp. 219-224 ◽  
Author(s):  
Kamil Yamak ◽  
Hüseyin Gökhan Karahan ◽  
Berrak Karatan ◽  
Cemil Kayalı ◽  
Taşkın Altay

Abstract Background The aim of this study is to evaluate the frequency of flexor pollicis longus (FPL) tendon rupture and factors leading to this rupture during the follow-up of patients who underwent volar plate fixation because of distal radius fracture. Patients and Methods A total of 109 distal radius fractures of 102 patients treated with volar plate fixation and periodically followed up for at least 1 year between January 2013 and May 2018 were evaluated. Fractures were categorized according to the AO Foundation/Orthopaedic Trauma Association (AO/OTA) Fracture-Dislocation Classification and Soong's grading was used for classifying volar plate position. All patients operated were inquired retrospectively in terms of flexor tendon rupture. Results Gender distribution revealed 45 females and 57 males. Mean age was 47.9 (range: 17–88) years. Mean period of follow-up was 27 months. Distribution of fractures in accordance with the AO/OTA distal radius classification was 6, 8, 7, 12, 24, 33, 11, and 8 patients with types A2, A3, B1, B2, B3, C1, C2, and C3, respectively. When volar plate positions were analyzed with Soong's classification, it revealed that 79 (72.4%), 23 (21.1%), and 7 (6.5%) plates were grade 0, 1, and 2, respectively. In total, evaluating the three patients with FPL rupture, it revealed that the volar plate was positioned distally during fixation because the fracture line had advanced to the distal of the watershed line, the distal portion of the plate had lost complete connection with the bone, and at this portion, it was observed that the pronator quadratus muscle was not covering the plate entirely (Soong's classification grade 2). Patients did not have additional flexor tendon injury. Conclusion FPL tendon rupture is a rare but serious complication of volar plate fixation performed for distal radius fractures. We believe that appropriate choice of implant and careful surgical technique, along with the close follow-up of patients, with Soong's classification grade-2 volar positions would help in preventing this complication. Level of Evidence This is a Level 3a, differential diagnosis/symptom prevalence study.


CJEM ◽  
2007 ◽  
Vol 9 (01) ◽  
pp. 9-15 ◽  
Author(s):  
Khalid Al-Ansari ◽  
Andrew Howard ◽  
Brian Seeto ◽  
Solina Yoo ◽  
Salma Zaki ◽  
...  

ABSTRACT Background: Emergency department (ED) manipulation of complete minimally angulated distal radius fractures in children may not be necessary, due to the excellent remodeling potential of these fractures. Objectives: The primary objective of this study was to determine the proportion of minimally angulated distal radius fractures managed in the ED with plaster immobilization that subsequently required manipulation. Our secondary objective was to document, at follow-up, changes in angulation for each wrist fracture. Methods: This retrospective cohort study reviewed consecutive records of all children with bi-cortical minimally angulated (≤15° of angulation in the sagittal plane and ≤0.5 cm of displacement) distal metaphyseal radius fractures, alone or in combination with distal ulnar fracture. Details of treatment, radiographic findings, and clinical outcomes during the subsequent orthopedic follow up were recorded. Results: Of 124 patients included in the analysis, none required manipulation after their ED visit. All but 14 (11.3%) fractures were angulated ≤20° within the follow-up period. Two (1.6%) fractures that were initially angulated ≤15° progressed to 30°–35°, but remodeled within 2 years to nearly perfect anatomic alignment. By 6 weeks post-injury, no patients had clinically apparent deformity and all had normal function. Conclusions: Minimally angulated fractures of the distal metaphyseal radius managed in plaster immobilization without reduction in the ED are unlikely to require future surgical intervention.


Sign in / Sign up

Export Citation Format

Share Document