Towards a spatiotemporal understanding of subsurface water injection-induced strain responses tracked by fiber-optic sensing

2021 ◽  
Vol 95 ◽  
pp. 104209
Author(s):  
Yankun Sun ◽  
Ziqiu Xue ◽  
Tsutomu Hashimoto
2021 ◽  
Author(s):  
Mohammed Al-Hashemi ◽  
Daria Spivakovskaya ◽  
Evert Moes ◽  
Peter in ‘t Panhuis ◽  
Gijs Hemink ◽  
...  

Abstract Fiber Optic Systems, such as Distributed Temperature Sensing (DTS), have been used for wellbore surveillance for more than two decades. One of the traditional applications of DTS is injectivity profiling, both for hydraulically fractured and non-fractured wells. There is a long history of determining injectivity profiles using temperature profiles, usually by analyzing warm-back data with largely pure heat conduction models or by employing a so-called "hot-slug" approach that requires tracking of a temperature transient that arises at the onset of injection. In many of these attempts there is no analysis performed for the key influencing physical factors that could create significant ambiguity in the interpretation results. Among such factors we will consider in detail is the possible impact of cross-flow during the early warm-back stage, but also the temperature transient signal that is related to the location of the fiber-optic sensing cable behind the casing when the fast transient data are used for interpretation such as the "hot slug" during re-injection. In this paper it will be shown that despite all such potential complications, the high frequency and quality of the transient data that can be obtained from a continuous DTS measurement allow for a highly reliable and robust evaluation of the injectivity profile. The well-known challenge of the ambiguity of the interpretation, produced by the interpretation methods that are conventionally used, is overcome using the innovative "Pressure Rate Temperature Transient Analysis" method that takes maximum use of the complete DTS transient data set and all other available data at the level of the model-based interpretation. This method is based on conversion of field measurements into injectivity profiles taking into account the uncertainty in different parts of the data set, which includes the specifics of the DTS deployment, the uncertainty in surface flow rates, and possible data gaps in the history of the well. Several case studies will be discussed where this approach was applied to water injection wells. For the analysis, the re-injection and warmback DTS transient temperature measurements were taken from across the sandface. Furthermore, for comparison, injection profiles were also recorded by conventional PLTs in parallel. This case study will focus mostly on the advanced interpretation opportunities and the challenges related to crossflow through the wellbore during the warm-back phase, related to reservoir pressure dynamics, and finally related to the impact of the method of DTS deployment. In addition to describing the interpretation methodology, this paper will also show the final comparison of the fiber-optic evaluation with the interpretation obtained from the reference PLTs.


2021 ◽  
Author(s):  
Mischa Megens ◽  
Merel D. Leistikow ◽  
Anneke van Dusschoten ◽  
Martin B. van der Mark ◽  
Jeroen J.L. Horikx ◽  
...  

2021 ◽  
Author(s):  
Abdulaziz Al-Qasim ◽  
Sharidah Alabduh ◽  
Muhannad Alabdullateef ◽  
Mutaz Alsubhi

Abstract Fiber-optic sensing (FOS) technology is gradually becoming a pervasive tool in the monitoring and surveillance toolkit for reservoir engineers. Traditionally, sensing with fiber optic technology in the form of distributed temperature sensing (DTS) or distributed acoustic sensing (DAS), and most recently distributed strain sensing (DSS), distributed flow sensing (DFS) and distributed pressure sensing (DPS) were done with the fiber being permanently clamped either behind the casing or production tubing. Distributed chemical sensing (DCS) is still in the development phase. The emergence of the composite carbon-rod (CCR) system that can be easily deployed in and out of a well, similar to wireline logging, has opened up a vista of possibilities to obtain many FOS measurements in any well without prior fiber-optic installation. Currently, combinations of distributed FOS data are being used for injection management, well integrity monitoring, well stimulation and production performance optimization, thermal recovery management, etc. Is it possible to integrate many of the distributed FOS measurements in the CCR or a hybrid combination with wireline to obtain multiple measurements with one FOS cable? Each one of FOS has its own use to get certain data, or combination of FOS can be used to make a further interpretation. This paper reviews the state of the art of the FOS technology and the gamut of current different applications of FOS data in the oil and gas (upstream) industry. We present some results of traditional FOS measurements for well integrity monitoring, assessing production and injection flow profile, cross flow behind casing, etc. We propose some nontraditional applications of the technology and suggest a few ways through. Which the technology can be deployed for obtaining some key reservoir description and dynamics data for reservoir performance optimization.


Sign in / Sign up

Export Citation Format

Share Document