Stability-indicating reversed-phase HPLC method development and characterization of impurities in vortioxetine utilizing LC–MS, IR and NMR

2016 ◽  
Vol 117 ◽  
pp. 325-332 ◽  
Author(s):  
Lei Liu ◽  
Na Cao ◽  
Xingling Ma ◽  
Kaihe Xiong ◽  
Lili Sun ◽  
...  
2002 ◽  
Vol 25 (1) ◽  
pp. 101-111 ◽  
Author(s):  
P. Dallet ◽  
L. Labat ◽  
M. Richard ◽  
M. H. Langlois ◽  
J. P. Dubost

2020 ◽  
Vol 32 (3) ◽  
pp. 587-591
Author(s):  
Pankaj N. Kulkarni ◽  
C.K. Jadhav ◽  
A.S. Nipate ◽  
Alaknanda M. Dodake-Supekar ◽  
C.H. Gill

A new, simple, reliable and reproducible stability indicating RP-HPLC assay method has been developed for quantitative analysis of dexamethasone from dexamethasone tablets. This developed method has been validated according to ICH guideline with respect to system suitability, specificity, precision, linearity, accuracy and robustness. An isocratic condition of mobile phase water (0.1% orthophosphoric acid):acetonitrile in a ratio of 60:40, v/v at a flow rate of 1.0 mL/minute over RP 2.5 Fortis C18, 100 × 4.6 mm, 2.5 μm, column was at 27 ºC maintained. This method is specific and showed excellent linear response with correlation coefficient (R2) values of 0.999. In forced degradation, the proposed method has been investigated with different stress conditions as hydrolytic, oxidative, thermal and humid as recommended by ICH guidelines. An accurate and reliable reversed-phase HPLC method for the analysis of dexamethasone in dexamethasone tablets was developed and validated successfully.


INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (08) ◽  
pp. 54-61
Author(s):  
B. Venkateswara Rao ◽  
◽  
S. Vidyadhara ◽  
V. Basaveswara Rao

The prime aim of the present investigation was to develop and validate a novel, precise, accurate, specific, rapid and economical stability- indicating isocratic reverse phase liquid chromatography method for the quantitative simultaneous estimation of valsartan and hydrochlorothiazide in bulk and marketed formulations. Estimation of drugs in this combination was achieved with a C18 column [Kromasil 100-5 C18 column, P134 250 × 4.6 mm] kept at ambient temperature, isocratic mode using mobile phase of composition acetonitrile and phosphate buffer (40:60 V/V, pH 4). The flow rate was 0.8 ml/min and the effluents were monitored at 235 nm, using variable wavelength UV detector. The retention time of valsartan and hydrochlorothiazide were 2.65 min and 3.97 min, respectively. Validation of the method was done according to the ICH guidelines for different analytical parameters. The method was found to be linear over a range of 50-250 μg/mL for valsartan and hydrochlorothiazide. The established method was as reproducible with a %RSD value of less than 2 and having robustness and accuracy within the specified limits. Assay of marketed formulation was determined and was 99.04% and 99.8% respectively. The stressed samples were analyzed. The proposed method was found to be specific and stability indicating as no interfering peaks of degradation compounds and excipients were noticed. The proposed method can be successfully employed in the estimation of commercial formulations.


Sign in / Sign up

Export Citation Format

Share Document