Incidence and risk factors for aseptic baseplate loosening of reverse total shoulder arthroplasty

2018 ◽  
Vol 27 (12) ◽  
pp. 2145-2152 ◽  
Author(s):  
Alexander Bitzer ◽  
Jorge Rojas ◽  
Ian S. Patten ◽  
Jacob Joseph ◽  
Edward G. McFarland
2019 ◽  
Vol 12 (6) ◽  
pp. 375-389 ◽  
Author(s):  
Simon C Lau ◽  
Richard Large

Background The reverse total shoulder arthroplasty has become the most common method of arthroplasty of the shoulder. The complication of acromial or scapular stress fracture deserves consideration to describe incidence and determine whether prosthetic design or patient factors act as risk factors. Methods A systematic review of the literature was performed including the EMBASE, Medline and the Cochrane Library in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Results The search returned 565 articles. After exclusion, 25 papers remained. In total, 208 fractures were reported in the literature, with an overall incidence of 5% and stress fractures were more common than post-traumatic ones; 24 fractures underwent osteosynthesis and there were nine revision arthroplasty surgeries. Outcomes worsened after fracture – whether treated with surgery or not. In patients with scapular base fractures, there was an improvement in functional outcome scores after surgery. Heterogeneous reporting of the risk factors prior to fractures, treatment methods and outcomes made recommendations weak. Discussion Acromial stress fracture after reverse total shoulder arthroplasty occurs relatively commonly but is poorly reported in the literature. It is unclear whether immobilisation, fixation or revision arthroplasty is the best treatment, although fixation may offer a better outcome. In future, reports should aim for greater consistency to allow a better understanding of this condition.


2018 ◽  
Vol 19 (1) ◽  
pp. 13-17 ◽  
Author(s):  
Jonathan D. Barlow ◽  
Amy Ravindra ◽  
Sameer Jain ◽  
Jared A. Crasto ◽  
Julie Y. Bishop

2021 ◽  
Vol 30 (1) ◽  
pp. 57-64
Author(s):  
Chul-Hyun Cho ◽  
Yong Girl Rhee ◽  
Jae Chul Yoo ◽  
Jong Hun Ji ◽  
Doo-Sup Kim ◽  
...  

2021 ◽  
pp. 175857322110193
Author(s):  
Arjun K Reddy ◽  
Jake X Checketts ◽  
B Joshua Stephens ◽  
J Michael Anderson ◽  
Craig M Cooper ◽  
...  

Background Thus, the purpose of the present study was to (1) characterize common postoperative complications and (2) quantify the rates of revision in patients undergoing hemiarthroplasty to reverse total shoulder arthroplasty revisional surgery. We hypothesize that hardware loosenings will be the most common complication to occur in the sample, with the humeral component being the most common loosening. Methods This systematic review adhered to PRISMA reporting guideline. For our inclusion criteria, we included any study that contained intraoperative and/or postoperative complication data, and revision rates on patients who had undergone revision reverse total shoulder arthroplasty due to a failed hemiarthroplasty. Complications include neurologic injury, deep surgical site infections, hardware loosening/prosthetic instability, and postoperative fractures (acromion, glenoid, and humeral fractures). Results The study contained 22 studies that assessed complications from shoulders that had revision reverse total shoulder arthroplasty from a hemiarthroplasty, with a total sample of 925 shoulders. We found that the most common complication to occur was hardware loosenings (5.3%), and of the hardware loosenings, humeral loosenings (3.8%) were the most common. The revision rate was found to be 10.7%. Conclusion This systematic review found that revision reverse total shoulder arthroplasty for failed hemiarthroplasty has a high overall complication and reintervention rates, specifically for hardware loosening and revision rates.


2021 ◽  
pp. 175857322110329
Author(s):  
Therese E Parr ◽  
Jennifer K Anderson ◽  
Alan M. Marionneaux ◽  
John M Tokish ◽  
Stefan J Tolan ◽  
...  

Background In a reverse total shoulder arthroplasty, the altered glenohumeral joint center of rotation subjects the glenoid baseplate to increased shear forces and potential loosening. Methods This study examined glenoid baseplate micromotion and initial fixation strength with the application of direct shear force in a Sawbone model. The reverse total shoulder arthroplasty systems examined were the DJO Reverse® Shoulder Prosthesis, the Exactech Equinoxe® Reverse System, and the Tornier AequalisTM Reverse Shoulder Prosthesis. Specimens were cyclically tested with increasing shear loads until 150 µm of displacement between the implant and glenoid was achieved, and subsequently until failure, classified as either 1 cm of implant/glenoid displacement or fracture. Results The average load withstood for the 150 µm threshold for DJO, Tornier, and Exactech was 460 ± 88 N, 525 ± 100 N, and 585 ± 160 N, respectively. The average total load at device failure for DJO, Tornier, and Exactech was 980 ± 260 N, 1260 ± 120 N, and 1350 ± 230 N, respectively. Discussion The Exactech implant design trended toward requiring more load to induce micromotion at each threshold and to induce device failure, most commonly seen as inferior screw pull out. This study proposes design features that may enhance fixation and suggests little risk of initial micromotion or failure during initial post-operative recovery.


Sign in / Sign up

Export Citation Format

Share Document