Letter to the Editor regarding: “Reverse shoulder arthroplasty with and without latissimus and teres major transfer for patients with combined loss of elevation and external rotation: a prospective, randomized investigation”.

Author(s):  
Pascal Boileau ◽  
Mikael Chelli ◽  
Tyler R. Johnston ◽  
Gabriel Cardenas ◽  
Marc-Olivier Gauci
2020 ◽  
pp. 175857322092115
Author(s):  
Bradley S Schoch ◽  
Joseph J King ◽  
Joseph Zuckerman ◽  
Thomas W Wright ◽  
Chris Roche ◽  
...  

Background Anatomic total shoulder arthroplasty improves pain and function with a reported reoperation rate of approximately 1% per year. With improved glenoid fixation, reverse shoulder arthroplasty implants may outperform anatomic total shoulder arthroplasty. We evaluate the functional outcomes and reoperation rate of anatomic total shoulder arthroplasty versus reverse shoulder arthroplasty at a minimum eight-year follow-up or revision. Methods Between 2005 and 2010, 187 shoulders (137 anatomic total shoulder arthroplasty, 50 reverse shoulder arthroplasty) were retrospectively reviewed at a mean of 8.8 years. The mean age at surgery was 67 years. Females were more commonly treated with reverse shoulder arthroplasty. Both groups had similar body mass index and comorbidities. Outcome measures evaluated included abduction, forward elevation, external rotation, internal rotation, Simple Shoulder Test, Constant score, American Shoulder and Elbow Score, University of California Los Angeles Shoulder score, and Shoulder Pain and Disability Index. Results At follow-up, anatomic total shoulder arthroplasty demonstrated greater overhead range of motion and external rotation. All patient-reported outcomes remained similar between groups. Reverse shoulder arthroplasty patients were more likely to rate shoulders as much better or better after surgery (90% versus 67%, p = 0.004). Complications were observed in 24% of anatomic total shoulder arthroplasties and 8% of reverse shoulder arthroplasties (p = 0.02). Reoperation was more common in anatomic total shoulder arthroplasties (23% versus 4%, p = 0.003). Discussion At mid-to-long-term follow-up, reverse shoulder arthroplasties demonstrated significantly fewer complications and reoperations than anatomic total shoulder arthroplasties. Despite similar patient-reported outcomes, reverse shoulder arthroplasty patients were more likely to be satisfied with their shoulder.


2020 ◽  
pp. 175857322091684
Author(s):  
Richard Dimock ◽  
Mohamed Fathi Elabd ◽  
Mohamed Imam ◽  
Mark Middleton ◽  
Arnaud Godenèche ◽  
...  

Background Reverse shoulder arthroplasty (RSA) has revolutionized the management of many shoulder pathologies. Lateralization has become favourable to combat complications (e.g. notching, compromised external rotation), using a metallic, or autogenous bone-graft baseplates – bony increased-offset reverse shoulder arthroplasty (BIO-RSA). We systematically reviewed the literature to determine: Does BIO-RSA improve range of motion and outcome scores? Are notching rates decreased? Does the graft heal? Methods All available prospective studies, trials and case series reporting on BIO-RSA were included. Outcomes were grouped into outcome scores, range of motion and radiographic outcomes. Data were pooled and statistical analysis performed. Results Eight studies reported on 385 RSA – 235 BIO-RSA and 150 standard-RSA (STD-RSA). Follow-up was 20–36 months; average age 74 years. Outcome scores: Constant-Murley and SSV scores showed statistically significant post-operative benefit of BIO-RSA (mean-difference 4.0 (95% confidence interval (CI): 0.79,7.1) and 6.8 (95% CI: 3.8, 9.9)). No Minimal Clinically Importance Difference was surpassed. Range of motion: No difference was found in any direction. Notching: Notching was less likely with BIO-RSA (odds ratio 0.19 (95% CI: 0.10, 0.38)). Healing and loosening: 92% grafts fully healed/incorporated. Loosening rate was 2.4%. Conclusions Literature on BIO-RSA is limited with only one randomised controlled trial (RCT). Weak evidence exists for improved outcome scores. Range of motion is equivocal. Notching rates are significantly lower in BIO-RSA. The graft usually heals.


2019 ◽  
Vol 101-B (4) ◽  
pp. 461-469 ◽  
Author(s):  
A. Lädermann ◽  
A. J. Schwitzguebel ◽  
T. B. Edwards ◽  
A. Godeneche ◽  
L. Favard ◽  
...  

Aims The aim of this study was to report the outcomes of different treatment options for glenoid loosening following reverse shoulder arthroplasty (RSA) at a minimum follow-up of two years. Patients and Methods We retrospectively studied the records of 79 patients (19 men, 60 women; 84 shoulders) aged 70.4 years (21 to 87) treated for aseptic loosening of the glenosphere following RSA. Clinical evaluation included pre- and post-treatment active anterior elevation (AAE), external rotation, and Constant score. Results From the original cohort, 29 shoulders (35%) were treated conservatively, 27 shoulders (32%) were revised by revision of the glenosphere, and 28 shoulders (33%) were converted to hemiarthroplasty. At last follow-up, conservative treatment and glenoid revision significantly improved AAE, total Constant score, and pain, while hemiarthroplasty did not improve range of movement or clinical scores. Multivariable analysis confirmed that conservative treatment and glenoid revision achieved similar improvements in pain (glenoid revision vs conservative, beta 0.44; p = 0.834) but that outcomes were significantly worse following hemiarthroplasty (beta -5.00; p = 0.029). Conclusion When possible, glenoid loosening after RSA should first be treated conservatively, then by glenosphere revision if necessary, and last by salvage hemiarthroplasty Cite this article: Bone Joint J 2019;101-B:461–469.


2018 ◽  
Vol 100-B (9) ◽  
pp. 1182-1186 ◽  
Author(s):  
B. S. Werner ◽  
J. Chaoui ◽  
G. Walch

Aims Scapular notching is a frequently observed radiographic phenomenon in reverse shoulder arthroplasty (RSA), signifying impingement of components. The purposes of this study were to evaluate the effect of glenoid component size and glenosphere type on impingement-free range of movement (ROM) for extension and internal and external rotation in a virtual RSA model, and to determine the optimal configuration to reduce the incidence of friction-type scapular notching. Materials and Methods Preoperative CT scans obtained in 21 patients (three male, 18 female) with primary osteoarthritis were analyzed using modelling software. Two concurrent factors were tested for impingement-free ROM and translation of the centre of rotation: glenosphere diameter (36 mm vs 39 mm) and type (centred, 2 mm inferior eccentric offset, 10° inferior tilt). Results Glenosphere size was most predictive of increased extension and external rotation, whereas lateralization of the centre of rotation was the most predictive factor for internal rotation. A larger diameter of glenosphere combined with a 10° tilted configuration demonstrated superior values for extension and external rotation, whereas the eccentric component improved internal rotation by a mean 8.9° (standard deviation 2.7°) compared with a standard concentric glenosphere. Conclusion Glenosphere configuration can be modified to increase range of movement in RSA. Friction-type scapular notching was most effectively reduced by use of a large-diameter glenosphere with 10° inferior tilt. Cite this article: Bone Joint J 2018;100-B:1182–6.


Sign in / Sign up

Export Citation Format

Share Document