scholarly journals Dry-Weight Assessment Among Hemodialysis Patients Using Body Composition Monitor

2017 ◽  
Vol 20 (9) ◽  
pp. A864 ◽  
Author(s):  
A Khan ◽  
AH Khan ◽  
AS Adnan ◽  
SA Sulaiman ◽  
I Khan
2016 ◽  
Vol 31 (suppl_1) ◽  
pp. i231-i231
Author(s):  
Shin Fukunaga ◽  
Kazuhiro Yamada ◽  
Akiko Baba ◽  
Yuji Sato ◽  
Shouichi Fujimoto

2012 ◽  
Vol 31 (2) ◽  
pp. A23
Author(s):  
Stanislas Trolonge ◽  
Philippe Chauveau ◽  
Claude Desvergnes ◽  
Nicole Larroumet ◽  
Christian Combe

Nephron ◽  
2002 ◽  
Vol 92 (1) ◽  
pp. 91-96 ◽  
Author(s):  
Yi-Chou Chen ◽  
Han-Hsiang Chen ◽  
Jui-Chi Yeh ◽  
Ssu-Yuan Chen

Symmetry ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 150
Author(s):  
Maja Pajek ◽  
Vedrana Sember ◽  
Ivan Čuk ◽  
Jožef Šimenko ◽  
Jernej Pajek

Bioelectric impedance devices have become a standard of care not only for peritoneal dialysis but also for hemodialysis patients. We compared the most important body composition variables (extracellular water, intracellular water, total body water and fat mass) measured with the multifrequency bioelectric impedance device InBody 720 (MF-BIA) and bioimpedance spectroscopy body composition monitor Fresenius (BIS BCM) in hemodialysis patients (n = 51, 175.1 + 7.8 cm, 82.2 + 15.2 kg) and healthy controls (n = 51, 175.1 + 7.6 cm, 82.3 + 15.3 kg). The MF-BIA InBody 720 device compared to the BIS BCM device showed significantly larger total body water and intracellular water estimates and significantly smaller extracellular water and body fat estimates in hemodialysis patients (p < 0.001). These differences (p < 0.001) were similar in the cohort of healthy controls; moreover, we observed high correlations in all variables between the hemodialysis patients and the healthy controls (0.80–0.95, p < 0.001). The mean relative differences in the order of 8% were lower for extracellular water and total body fat, but the limits of agreement were still wide enough to be clinically significant. We conclude that the results of the measurements with InBody 720 and BCM Fresenius cannot be used interchangeably. Physicians and nutritionists involved in the care of hemodialysis patients should be aware of this discrepancy between the two devices and should try to use the same device to track the body in their hemodialysis population in a longitudinal direction.


2012 ◽  
Vol 21 (19pt20) ◽  
pp. 2879-2885 ◽  
Author(s):  
Rafidah Mamat ◽  
Norella CT Kong ◽  
Arbai’yah Ba’in ◽  
Shamsul A Shah ◽  
Rizna Cader ◽  
...  

2014 ◽  
Vol 28 (1) ◽  
pp. 35-38 ◽  
Author(s):  
Hassan Argani ◽  
Reza Mahdavi ◽  
Amir Ghorbani-haghjo ◽  
Reza Razzaghi ◽  
Leila Nikniaz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document