scholarly journals Long-term use of modern Portland cement concrete: The impact of Al-tobermorite formation

2021 ◽  
Vol 198 ◽  
pp. 109297
Author(s):  
Ippei Maruyama ◽  
Jiří Rymeš ◽  
Abudushalamu Aili ◽  
Shohei Sawada ◽  
Osamu Kontani ◽  
...  
Author(s):  
Soheil Nazarian ◽  
Deren Yuan ◽  
Mark R. Baker

Coring is normally done to monitor the thickness and quality of portland cement concrete (PCC) slabs during construction. Because this procedure requires a considerable amount of time, it is done at widely spaced intervals. As a result, the most critical points, in terms of strength or thickness, are sometimes not tested. Their repeatability and extreme sensitivity to the properties of surface layer enable wave propagation techniques to be used for quality control. The main advantage of these techniques is that they are nondestructive. Fortunately, these techniques have been automated in the last few years. Two seismic devices (seismic pavement analyzer and a portable version of it called the Lunch Box) have been used extensively for quality control. With them, slabs can be tested at closely spaced points and at a fraction of the cost and time of coring. The main tests used are the impact echo for determining the thickness of the slab, the ultrasonic body wave for determining the modulus, and the ultrasonic surface wave (an offshoot of the spectral analysis of surface waves method) also for determining the modulus. On the basis of extensive field testing on many types of base and subgrade, the techniques in general—and the two devices in particular—are suitable for many quality-control projects. It was found that the most robust method for determining the modulus is the ultrasonic surface wave. The impact echo also works well, as long as enough contrast exists between the properties of the PCC and the underlying materials.


Author(s):  
Thomas Van Dam ◽  
James Bildilli

The deterioration and performance of portland cement concrete general aviation (GA) airport pavements in Illinois are discussed. Two popular design procedures are reviewed, and typical GA pavement sections are structurally evaluated by using the ILLI-SLAB finite-element model. Subjected to GA pavement loading conditions, 125- and 150-mm-thick slabs would be considered structurally adequate, whereas 100-mm-thick slabs would not be expected to perform well. It was determined that slab size, as determined by the ratio of the slab length over the radius of relative stiffness (L/ l) was strongly correlated to pavement distress and performance. As the slab size was increased higher incidences of distress at higher severity levels were observed. Performance trends were identified by using a deterioration rate approach that accounts for the performance of individual sections. It is believed that this procedure reflects actual performance trends by addressing the issues of long-lived pavement sections, the impact of maintenance, and the influence of inspection variability.


1999 ◽  
Vol 29 (4) ◽  
pp. 515-521 ◽  
Author(s):  
S.R. Hillier ◽  
C.M. Sangha ◽  
B.A. Plunkett ◽  
P.J. Walden

Author(s):  
James K. Cable

Load transfer is an important aspect of portland cement concrete joint design. To date, aggregate interlock and round steel dowels have been used to accomplish load transfer. Research was done to examine the use of steel dowels of alternative shapes to provide load transfer. A field research project in Iowa has used two elliptical bars of different sizes at three spacings and numbers of bars per joint. Test sections included bars across the entire joint and sections using bars only in the wheelpaths. The impact of cut, fill, and transition sections was also factored into the experimental design. This paper documents the construction of the project, testing that is being done, and the initial results of the work.


2015 ◽  
Vol 10 (4) ◽  
pp. 87-106
Author(s):  
Brett Tempest ◽  
Janos Gergely ◽  
David C. Weggel

Geopolymer cements provide an alternative to the Portland cement used to produce structural concrete. In this study, geopolymer cements were used to create concrete having compressive strength in the range of 34 to 83 MPa (5,000–12,000 psi). The mechanical properties of these concrete materials were evaluated to determine the compressive and tensile strengths and immediate and long term elastic behaviors. The geopolymer cement concrete (GCC) was found to perform in a similar manner to Portland cement concrete (PCC). Long term shrinkage and creep properties of GCC materials were found to be lower than the values typical for PCC.


1997 ◽  
Vol 503 ◽  
Author(s):  
B. K. Diefenderfer ◽  
I. L. Al-Qadi ◽  
J. J. Yoho ◽  
S. M. Riad ◽  
A. Loulizi

ABSTRACTPortland cement concrete (PCC) structures deteriorate with age and need to be maintained or replaced. Early detection of deterioration in PCC (e.g., alkali-silica reaction, freeze/thaw damage, or chloride presence) can lead to significant reductions in maintenance costs. However, it is often too late to perform low-cost preventative maintenance by the time deterioration becomes evident. By developing techniques that would enable civil engineers to evaluate PCC structures and detect deterioration at early stages (without causing further damage), optimization of life-cycle costs of the constructed facility and minimization of disturbance to the facility users can be achieved.Nondestructive evaluation (NDE) methods are potentially one of the most useful techniques ever developed for assessing constructed facilities. They are noninvasive and can be performed rapidly. Portland cement concrete can be nondestructively evaluated by electrically characterizing its complex dielectric constant. The real part of the dielectric constant depicts the velocity of electromagnetic waves in PCC. The imaginary part, termed the “loss factor,” describes the conductivity of PCC and the attenuation of electromagnetic waves.Dielectric properties of PCC have been investigated in a laboratory setting using a parallel plate capacitor operating in the frequency range of 0.1 to 40.1MIHz. This capacitor set-up consists of two horizontal-parallel plates with an adjustable separation for insertion of a dielectric specimen (PCC). While useful in research, this approach is not practical for field implementation. A new capacitor probe has been developed which consists of two plates, located within the same horizontal plane, for placement upon the specimen to be tested. Preliminary results show that this technique is feasible and results are promising; further testing and evaluation is currently underway.


Sign in / Sign up

Export Citation Format

Share Document