A multi-scale approach for detection of ischemic stroke from brain MR images using discrete curvelet transformation

Measurement ◽  
2017 ◽  
Vol 100 ◽  
pp. 223-232 ◽  
Author(s):  
R. Karthik ◽  
R. Menaka
2021 ◽  
Vol 11 (2) ◽  
pp. 386-390
Author(s):  
Aiguo Chen ◽  
Haoyuan Yan

In this paper, an improved fast FCM (HF-KFCM) algorithm was proposed based on histogram statistics of brain MR images. The algorithm firstly uses the multi-scale window traversal method to find the peak point of the histogram, then uses it as the initialization center of fuzzy clustering, and finally uses the fast clustering method based on statistical information to traverse, so as to reduce the computation amount of each iteration. Experimental results show that compared with the standard FCM algorithm and other improved algorithms, the proposed algorithm is significantly improved in clustering effectiveness and fuzzy segmentation.


2020 ◽  
Vol 26 (5) ◽  
pp. 517-524
Author(s):  
Noah S. Cutler ◽  
Sudharsan Srinivasan ◽  
Bryan L. Aaron ◽  
Sharath Kumar Anand ◽  
Michael S. Kang ◽  
...  

OBJECTIVENormal percentile growth charts for head circumference, length, and weight are well-established tools for clinicians to detect abnormal growth patterns. Currently, no standard exists for evaluating normal size or growth of cerebral ventricular volume. The current standard practice relies on clinical experience for a subjective assessment of cerebral ventricular size to determine whether a patient is outside the normal volume range. An improved definition of normal ventricular volumes would facilitate a more data-driven diagnostic process. The authors sought to develop a growth curve of cerebral ventricular volumes using a large number of normal pediatric brain MR images.METHODSThe authors performed a retrospective analysis of patients aged 0 to 18 years, who were evaluated at their institution between 2009 and 2016 with brain MRI performed for headaches, convulsions, or head injury. Patients were excluded for diagnoses of hydrocephalus, congenital brain malformations, intracranial hemorrhage, meningitis, or intracranial mass lesions established at any time during a 3- to 10-year follow-up. The volume of the cerebral ventricles for each T2-weighted MRI sequence was calculated with a custom semiautomated segmentation program written in MATLAB. Normal percentile curves were calculated using the lambda-mu-sigma smoothing method.RESULTSVentricular volume was calculated for 687 normal brain MR images obtained in 617 different patients. A chart with standardized growth curves was developed from this set of normal ventricular volumes representing the 5th, 10th, 25th, 50th, 75th, 90th, and 95th percentiles. The charted data were binned by age at scan date by 3-month intervals for ages 0–1 year, 6-month intervals for ages 1–3 years, and 12-month intervals for ages 3–18 years. Additional percentile values were calculated for boys only and girls only.CONCLUSIONSThe authors developed centile estimation growth charts of normal 3D ventricular volumes measured on brain MRI for pediatric patients. These charts may serve as a quantitative clinical reference to help discern normal variance from pathologic ventriculomegaly.


Author(s):  
Pooja Prabhu ◽  
A. K. Karunakar ◽  
Sanjib Sinha ◽  
N. Mariyappa ◽  
G. K. Bhargava ◽  
...  

AbstractIn a general scenario, the brain images acquired from magnetic resonance imaging (MRI) may experience tilt, distorting brain MR images. The tilt experienced by the brain MR images may result in misalignment during image registration for medical applications. Manually correcting (or estimating) the tilt on a large scale is time-consuming, expensive, and needs brain anatomy expertise. Thus, there is a need for an automatic way of performing tilt correction in three orthogonal directions (X, Y, Z). The proposed work aims to correct the tilt automatically by measuring the pitch angle, yaw angle, and roll angle in X-axis, Z-axis, and Y-axis, respectively. For correction of the tilt around the Z-axis (pointing to the superior direction), image processing techniques, principal component analysis, and similarity measures are used. Also, for correction of the tilt around the X-axis (pointing to the right direction), morphological operations, and tilt correction around the Y-axis (pointing to the anterior direction), orthogonal regression is used. The proposed approach was applied to adjust the tilt observed in the T1- and T2-weighted MR images. The simulation study with the proposed algorithm yielded an error of 0.40 ± 0.09°, and it outperformed the other existing studies. The tilt angle (in degrees) obtained is ranged from 6.2 ± 3.94, 2.35 ± 2.61, and 5 ± 4.36 in X-, Z-, and Y-directions, respectively, by using the proposed algorithm. The proposed work corrects the tilt more accurately and robustly when compared with existing studies.


2021 ◽  
Vol 168 ◽  
pp. 114426
Author(s):  
Rutuparna Panda ◽  
Leena Samantaray ◽  
Akankshya Das ◽  
Sanjay Agrawal ◽  
Ajith Abraham

Sign in / Sign up

Export Citation Format

Share Document