Gas/liquid membrane contactors based on disubstituted polyacetylene for CO2 absorption liquid regeneration at high pressure and temperature

2011 ◽  
Vol 383 (1-2) ◽  
pp. 241-249 ◽  
Author(s):  
Alexander Trusov ◽  
Sergey Legkov ◽  
Leo J.P. van den Broeke ◽  
Earl Goetheer ◽  
Valery Khotimsky ◽  
...  
Processes ◽  
2021 ◽  
Vol 9 (9) ◽  
pp. 1580
Author(s):  
Chii-Dong Ho ◽  
Hsuan Chang ◽  
Yih-Hang Chen ◽  
Jun-Wei Lim ◽  
Jing-Wei Liou

A new design of gas absorption that winds the permeable membrane onto an inner concentric tube to conduct a concentric circular gas–liquid membrane module has been studied theoretically in the fully developed region. An analytical formulation, referred to as conjugated Graetz problems, is developed to predict the concentration distribution and Sherwood numbers for the absorbent fluid flowing in the shell side and CO2/N2 gas mixture flowing in the tube side under various designs and operating parameters. The analytical solutions to the CO2 absorption efficiency were developed by using a two-dimensional mathematical modeling, and the resultant conjugated partial differential equations were solved analytically using the method of separation variables and eigen-function expansion in terms of power series. The predictions of CO2 absorption rate by using Monoethanolamide (MEA) solution in concentric circular membrane contactors under both concurrent- and countercurrent-flow operations are developed theoretically and confirmed with the experimental results. Consistency in both a good qualitative and quantitative sense is achieved between the theoretical predictions and experimental results. The advantage of the present mathematical treatment provides a concise expression for the chemical absorption of CO2 by MEA solution to calculate the absorption rate, absorption efficiency, and average Sherwood number. The concentration profiles with the mass-transfer Graetz number, inlet CO2 concentration, and both gas feed and absorbent flow rates are also emphasized. Both theoretical predictions and experimental results show that the device performance of the countercurrent-flow operation is better than that of the concurrent-flow device operation. The availability of such simplified expressions of the absorption rate and averaged Sherwood as developed directly from the analytical solutions is the value of the present study.


Author(s):  
Egor Koemets ◽  
Timofey Fedotenko ◽  
Saiana Khandarkhaeva ◽  
Maxim Bykov ◽  
Elena Bykova ◽  
...  

Author(s):  
Egor Koemets ◽  
Timofey Fedotenko ◽  
Saiana Khandarkhaeva ◽  
Maxim Bykov ◽  
Elena Bykova ◽  
...  

Membranes ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 496
Author(s):  
Sayali Ramdas Chavan ◽  
Patrick Perré ◽  
Victor Pozzobon ◽  
Julien Lemaire

Recently, membrane contactors have gained more popularity in the field of CO2 removal; however, achieving high purity and competitive recovery for poor soluble gas (H2, N2, or CH4) remains elusive. Hence, a novel process for CO2 removal from a mixture of gases using hollow fiber membrane contactors is investigated theoretically and experimentally. A theoretical model is constructed to show that the dissolved residual CO2 hinders the capacity of the absorbent when it is regenerated. This model, backed up by experimental investigation, proves that achieving a purity > 99% without consuming excessive chemicals or energy remains challenging in a closed-loop system. As a solution, a novel strategy is proposed: the pH Swing Absorption which consists of manipulating the acido–basic equilibrium of CO2 in the absorption and desorption stages by injecting moderate acid and base amount. It aims at decreasing CO2 residual content in the regenerated absorbent, by converting CO2 into its ionic counterparts (HCO3− or CO32−) before absorption and improving CO2 degassing before desorption. Therefore, this strategy unlocks the theoretical limitation due to equilibrium with CO2 residual content in the absorbent and increases considerably the maximum achievable purity. Results also show the dependency of the performance on operating conditions such as total gas pressure and liquid flowrate. For N2/CO2 mixture, this process achieved a nitrogen purity of 99.97% with a N2 recovery rate of 94.13%. Similarly, for H2/CO2 mixture, a maximum H2 purity of 99.96% and recovery rate of 93.96% was obtained using this process. Moreover, the proposed patented process could potentially reduce energy or chemicals consumption.


2020 ◽  
Vol 4 (12) ◽  
Author(s):  
Takahiro Matsuoka ◽  
Hiroshi Fujihisa ◽  
Takahiro Ishikawa ◽  
Takaya Nakagawa ◽  
Keiji Kuno ◽  
...  

2013 ◽  
Vol 97 ◽  
pp. 1-9 ◽  
Author(s):  
Gema Cabello ◽  
Gary P. Funkhouser ◽  
Juanita Cassidy ◽  
Chad E. Kiser ◽  
Jim Lane ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document