Enhanced H2/CH4 and H2/CO2 separation by carbon molecular sieve membrane coated on titania modified alumina support: Effects of TiO2 intermediate layer preparation variables on interfacial adhesion

2016 ◽  
Vol 510 ◽  
pp. 391-404 ◽  
Author(s):  
Hui-Hsin Tseng ◽  
Ching-Ting Wang ◽  
Guo-Liang Zhuang ◽  
Petr Uchytil ◽  
Jirina Reznickova ◽  
...  
Membranes ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 93
Author(s):  
DaeHun Kim ◽  
YongSung Kwon ◽  
Jung-Hyun Lee ◽  
Seong-Joong Kim ◽  
You-In Park

For ethylene/ethane separation, a CMS (carbon molecular sieve) membrane was developed with a PAN (polyacrylonitrile) polymer precursor on an alumina support. To provide an excellent thermal property to PAN precursor prior to the pyrolysis, the stabilization as a pre-treatment process was carried out. Tuning the stabilization condition was very important to successfully preparing the CMS membrane derived from the PAN precursor. The stabilization and pyrolysis processes for the PAN precursor were finely tuned, and optimized in terms of stabilization temperature and time, as well as pyrolysis temperature, heating rate, and soaking time. The PAN stabilized at >250 °C showed improved thermal stability and carbon yield. The CMS membrane derived from stabilized PAN showed reasonable separation performance for ethylene permeance (0.71 GPU) and ethylene/ethane selectivity (7.62), respectively. Increasing the pyrolysis temperature and soaking time gave rise to an increase in the gas permeance, and a reduction in the membrane selectivity. This trend was opposite to that for the CMS membranes derived from other polymer precursors. The optimized separation performance (ethylene permeance of 2.97 GPU and ethylene/ethane selectivity of 7.25) could be achieved at the pyrolysis temperature of 650 °C with a soaking time of 1 h. The separation performance of the CMS membrane derived from the PAN precursor was comparable to that of other polymer precursors, and surpassed them regarding the upper bound trade off.


2011 ◽  
Vol 92 (5) ◽  
pp. 915-919 ◽  
Author(s):  
Juan Alcañiz-Monge ◽  
Juan Pablo Marco-Lozar ◽  
María Ángeles Lillo-Ródenas

Chemosensors ◽  
2021 ◽  
Vol 9 (5) ◽  
pp. 104
Author(s):  
Hung-Yang Kuo ◽  
Wei-Riu Cheng ◽  
Tzu-Heng Wu ◽  
Horn-Jiunn Sheen ◽  
Chih-Chia Wang ◽  
...  

This paper presents the synthesis and evaluation of a carbon molecular sieve membrane (CMSM) grown inside a MEMS-fabricated μ-preconcentrator for sampling highly volatile organic compounds. An array of µ-pillars measuring 100 µm in diameter and 250 µm in height were fabricated inside a microfluidic channel to increase the attaching surface for the CMSM. The surface area of the CMSM was measured as high as 899 m2/g. A GC peak amplification factor >2 × 104 was demonstrated with gaseous ethyl acetate. Up to 1.4 L of gaseous ethanol at the 100 ppb level could be concentrated without exceeding the capacity of this microchip device. Sharp desorption chromatographic peaks (<3.5 s) were obtained while using this device directly as a GC injector. Less volatile compounds such as gaseous toluene, m-xylene, and mesitylene appeared to be adsorbed strongly on CMSM, showing a memory effect. Sampling parameters such as sample volatilities, sampling capacities, and compound residual issues were empirically determined and discussed.


2018 ◽  
Vol 39 (17) ◽  
pp. 2218-2227 ◽  
Author(s):  
Li-Jing Du ◽  
Jian-Ping Huang ◽  
Bin Wang ◽  
Chen-Hui Wang ◽  
Qiu-Yan Wang ◽  
...  

2020 ◽  
Vol 132 (46) ◽  
pp. 20523-20527
Author(s):  
Oishi Sanyal ◽  
Samuel S. Hays ◽  
Nicholas E. León ◽  
Yoseph A. Guta ◽  
Arun K. Itta ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document