Study of quality factor and hysteresis associated with the state-of-the-art passive seismic isolation system for Gravitational Wave Interferometric Detectors

Author(s):  
R. Desalvo ◽  
Sz. Márka ◽  
K. Numata ◽  
V. Sannibale ◽  
A. Takamori ◽  
...  
2020 ◽  
Vol 20 (03) ◽  
pp. 2030001 ◽  
Author(s):  
Jie Tan ◽  
Peng Zhang ◽  
Qian Feng ◽  
Gangbing Song

Piping systems are typical nonstructural components of a building. Previous investigations have reported many cases that earthquake causes damages or failures of piping system, resulting in secondary disasters. Therefore, this paper conducts a survey of the seismic damage of the piping systems of buildings and then reviews the state-of-the-art of the passive seismic protection methods. This paper proposes to classify the building piping system into rigid connected pipes, flexible connected pipes and semi-rigid connected pipes. Typical seismic damages of building pipes are presented following this classification. Then, several current seismic protection methods (including constructional measures, seismic braces, damping techniques and base isolation methods) are discussed regarding the theoretical mechanism and feasibility. Furthermore, the state-of-the-art of the building piping system and the passive protection methods with application prospects are evaluated. Based on the review, the flexible piping systems are most commonly used in existing old buildings and are more vulnerable in earthquakes due to their high flexibility. New buildings prefer the rigid connections which tend to restrain the motion of the pipe. However, the excessive stiffness of the rigid connection may cause overlarge internal stresses in both the connection and the pipe. Semi-rigid piping systems have sufficient overall stiffness and a degree of local deform ability and thus have the best seismic performance. In future studies, more research should be devoted to propose and develop new dampers suitable for piping systems, which will improve the seismic safety of building piping systems.


Author(s):  
Hironori FURUKAWA ◽  
Takafumi FUJITA ◽  
Takayoshi KAMADA ◽  
Hideaki MISOKA

Author(s):  
T. A. Welton

Various authors have emphasized the spatial information resident in an electron micrograph taken with adequately coherent radiation. In view of the completion of at least one such instrument, this opportunity is taken to summarize the state of the art of processing such micrographs. We use the usual symbols for the aberration coefficients, and supplement these with £ and 6 for the transverse coherence length and the fractional energy spread respectively. He also assume a weak, biologically interesting sample, with principal interest lying in the molecular skeleton remaining after obvious hydrogen loss and other radiation damage has occurred.


2003 ◽  
Vol 48 (6) ◽  
pp. 826-829 ◽  
Author(s):  
Eric Amsel
Keyword(s):  

1968 ◽  
Vol 13 (9) ◽  
pp. 479-480
Author(s):  
LEWIS PETRINOVICH
Keyword(s):  

1984 ◽  
Vol 29 (5) ◽  
pp. 426-428
Author(s):  
Anthony R. D'Augelli

1991 ◽  
Vol 36 (2) ◽  
pp. 140-140
Author(s):  
John A. Corson
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document