scholarly journals Same survival but higher rate of osteolysis for metal-on-metal Ultamet versus ceramic-on-ceramic in patients undergoing primary total hip arthroplasty after 8 years of follow-up

2018 ◽  
Vol 104 (8) ◽  
pp. 1155-1161 ◽  
Author(s):  
Yoshitoshi Higuchi ◽  
Taisuke Seki ◽  
Yasuhiko Takegami ◽  
Daigo Komatsu ◽  
Daigo Morita ◽  
...  
2008 ◽  
Vol 26 (12) ◽  
pp. 1569-1576 ◽  
Author(s):  
Lucia Savarino ◽  
Giovanni Padovani ◽  
Massimo Ferretti ◽  
Michelina Greco ◽  
Elisabetta Cenni ◽  
...  

PLoS ONE ◽  
2016 ◽  
Vol 11 (6) ◽  
pp. e0156051 ◽  
Author(s):  
B. G. Pijls ◽  
J. M. T. A. Meessen ◽  
J. W. Schoones ◽  
M. Fiocco ◽  
H. J. L. van der Heide ◽  
...  

2021 ◽  
Vol 9 ◽  
pp. 205031212110147
Author(s):  
Nobuhiko Sumiyoshi ◽  
Kazuhiro Oinuma ◽  
Yoko Miura

Background: Adverse reactions to metal debris are significant complications after metal-on-metal total hip arthroplasty. Recently, late appearances of adverse reactions to metal debris and subsequent need for reoperations have been reported with small-diameter head metal-on-metal devices. We retrospectively investigated mid-term clinical outcomes of small-head metal-on-metal total hip arthroplasty. Methods: We reviewed 159 hips in 139 patients who had a small-head metal-on-metal total hip arthroplasty (M2a Taper; Biomet, Warsaw, IN) with a minimum 5-year follow-up and documented postoperative complications. Results: Focal osteolysis in either the femur or acetabulum was observed in 12 hips (7.5%, 44 months after surgery on average), with pseudotumor observed in 8 hips (5%, 120 months after surgery on average). Four hips (2.5%) had dislocations (84 months after surgery on average) and six hips (3.8%, 122 months after surgery on average) underwent reoperation. Conclusion: Small-head metal-on-metal total hip arthroplasty is associated with a high degree of complications at mid-term follow-up period. Considering this, we discourage the use of metal-on-metal total hip arthroplasty regardless of head size.


2020 ◽  
pp. 112070002096964
Author(s):  
Kirill Gromov ◽  
Nanna H Sillesen ◽  
Thomas Kallemose ◽  
Henrik Husted ◽  
Henrik Malchau ◽  
...  

Background: Introduction of new implants should be monitored closely to capture any signs of compromising patient safety. Vitamin E infused highly-crosslinked polyethylene liners (VEPE) offer the potential for reduced wear. Highwall liners have been hypothesised to result in increased wear and potential liner fractures. The aim of this study was to determine the 3–7-year follow-up of highwall VEPE for primary total hip arthroplasty (THA), focusing on liner-related complications. Methods: We included 1221 consecutive THA operations from July 2010 to May 2014 with minimum follow-up of 3 (3.1–6.8) years Data collected included demographics, implant data, complications, reoperations, and deaths. Data were cross-referenced with the Danish Hip Arthroplasty Registry in order to ensure validity and completeness. Acetabular shell position was measured using Martell Hip Analysis Suite in a subgroup of 931 THAs. Results: Cumulative stem revision and shell revision at 3-year follow-up was 3.4% and 0.4% respectively. There were no revisions due to liner failure. Reason for revision included 11 dislocations, 15 soft-tissue revisions for infection, 44 stem revisions of which 34 were periprosthetic fractures and 13 shell revisions of which 6 were combined shell and stem revisions. Conclusion: Early follow-up of VEPE liners for primary THA have not shown any revisions associated with liner failure. Continued monitoring of new materials are necessary to capture any signs of compromised patient safety.


2017 ◽  
Vol 01 (04) ◽  
pp. 200-204 ◽  
Author(s):  
Roby Abraham ◽  
Joseph Scollan ◽  
Patrick Mixa ◽  
Denis Cherkalin ◽  
Jeffrey Varghese ◽  
...  

AbstractGunshot wound (GSW) injuries around the hip joint can lead to debilitating post-traumatic arthritis, requiring a technically demanding primary total hip arthroplasty (THA). These surgeries are often complicated by bullet debris, extensive scaring, prior operations, and altered local anatomy. Although most literature focuses on acute management of GSW around the hip, a few reports detail the mid-term outcomes of GSW patients with primary THA for post-traumatic arthritis. The purpose of this study was to assess the outcomes and complications associated with THA in nine patients with secondary arthritis due to prior GSW injuries. At a mean follow-up of 35 months (range 12–60 months), significant improvement was shown in hip function, activity, and pain levels, and was similar to the outcomes of 18 patients who underwent primary THA for degenerative joint disease. While technically demanding, THA seems to reduce pain and improve function safely and effectively for patients with GSW-induced hip arthritis.


Sign in / Sign up

Export Citation Format

Share Document