scholarly journals Right ventricular lead location and outcomes among patients with cardiac resynchronization therapy: A meta-analysis

Author(s):  
Fatima Ali-Ahmed ◽  
Frederik Dalgaard ◽  
Nancy M. Allen Lapointe ◽  
Andrzej S. Kosinski ◽  
Vanessa Blumer ◽  
...  
EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
A Behon ◽  
W R Schwertner ◽  
E D Merkel ◽  
A Kovacs ◽  
V Kutyifa ◽  
...  

Abstract Background There is limited data on the association of left ventricular (LV) lead position and long-term clinical outcome in patients after cardiac resynchronization therapy (CRT). Purpose We evaluated the mid-term echocardiographic response and long-term all-cause mortality of patients who underwent CRT implantation by LV lead non-apical positions and further characterized them by right to left ventricular, interlead electrical delay (IED). Methods In our retrospective registry patients after CRT implantation between 2000 and 2018 were registered. Those with non-apical LV lead location were classified into anterior (n = 111), posterior (n = 652), and lateral (n = 1373) positions. Primary endpoint was all-cause mortality assessed by univariate- and Cox multivariate analyses. Secondary endpoint was echocardiographic response within 6 months after CRT implantation. Results From 2136 patients 1180 (55.2%) reached the primary endpoint during the mean follow up time of 4.5 years. Univariate analysis showed patients with lateral position had significantly better outcome compared to others (HR 0.80; 95% CI: 0.71-0.90; p < 0.01), which was also confirmed by Cox multivariate analysis (HR 0.69; 95% CI: 0.50-0.93; p = 0.02) after adjusting for relevant clinical covariates such as IED and LBBB. The median value of IED was 106 (89/124) ms in the total patient cohort, which was significantly longer in the lateral group [anterior 80 (60/100) ms vs. lateral 110 (91/128) ms vs. posterior 100 (85/120) ms; p< 0.01]. When echocardiographic response was further evaluated in patients with lateral position, those with an IED longer than 110 ms (ROC AUC 0.64, 95% CI: 0.54-0.74; p = 0.01) showed the greatest benefit within 6 months. Conclusions After CRT implantation the most beneficial outcome was associated with lateral left ventricular lead location, moreover the greatest echocardiographic response was found when interlead electrical delay was longer than 110 ms in this group. Abstract Figure. All-cause mortality of total cohort


Sign in / Sign up

Export Citation Format

Share Document