Application of an aerosol shock tube to the measurement of diesel ignition delay times

2009 ◽  
Vol 32 (1) ◽  
pp. 477-484 ◽  
Author(s):  
D.R. Haylett ◽  
P.P. Lappas ◽  
D.F. Davidson ◽  
R.K. Hanson
2016 ◽  
Vol 164 ◽  
pp. 152-163 ◽  
Author(s):  
Batikan Koroglu ◽  
Owen M. Pryor ◽  
Joseph Lopez ◽  
Leigh Nash ◽  
Subith S. Vasu

2015 ◽  
Vol 137 (6) ◽  
Author(s):  
Ghassan Nicolas ◽  
Hameed Metghalchi

The rate-controlled constrained-equilibrium (RCCE) method is a reduction technique based on local maximization of entropy or minimization of a relevant free energy at any time during the nonequilibrium evolution of the system subject to a set of kinetic constraints. In this paper, RCCE has been used to predict ignition delay times of low temperatures methane/air mixtures in shock tube. A new thermodynamic model along with RCCE kinetics has been developed to model thermodynamic states of the mixture in the shock tube. Results are in excellent agreement with experimental measurements.


2022 ◽  
Author(s):  
Michael Pierro ◽  
Andrew Laich ◽  
Justin J. Urso ◽  
Cory Kinney ◽  
Subith Vasu ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 683
Author(s):  
Erwei Liu ◽  
Qin Liao ◽  
Shengli Xu

An aerosol shock tube has been developed for measuring the ignition delay times (tig) of aerosol mixtures of low-vapor-pressure fuels and for visualization of the auto-ignition flow-field. The aerosol mixture was formed in a premixing tank through an atomizing nozzle. Condensation and adsorption of suspended droplets were not observed significantly in the premixing tank and test section. A particle size analyzer was used to measure the Sauter mean diameter (SMD) of the aerosol droplets. Three pressure sensors and a photomultiplier were used to detect local pressure and OH emission respectively. Intensified charge-coupled device cameras were used to capture sequential images of the auto-ignition flow-field. The results indicated that stable and uniform aerosol could be obtained by this kind of atomizing method and gas distribution system. The averaged SMD for droplets of toluene ranged from 2 to 5 μ m at pressures of 0.14–0.19 MPa of dilute gases. In the case of a stoichiometric mixture of toluene/O2/N2, ignition delay times ranged from 77 to 1330 μs at pressures of 0.1–0.3 MPa, temperatures of 1432–1716 K and equivalence ratios of 0.5–1.5. The logarithm of ignition delay times was approximately linearly correlated to 1000/T. In contrast to the reference data, ignition delay times of aerosol toluene/O2/N2 were generally larger. Sequential images of auto-ignition flow-field showed the features of flame from generation to propagation.


Sign in / Sign up

Export Citation Format

Share Document