scholarly journals Air-conditioning system with underfloor air distribution integrated solar chimney in data center

2017 ◽  
Vol 205 ◽  
pp. 3420-3427 ◽  
Author(s):  
Yang Gao ◽  
Jinxiang Liu ◽  
Xiaolei Yuan ◽  
Kai Zhang ◽  
Yujia Yang ◽  
...  
2020 ◽  
Vol 160 ◽  
pp. 99-111 ◽  
Author(s):  
Zongwei Han ◽  
Haotian Wei ◽  
Xiaoqing Sun ◽  
Chenguang Bai ◽  
Da Xue ◽  
...  

2014 ◽  
Vol 672-674 ◽  
pp. 518-521
Author(s):  
Li Fei Song ◽  
Tao Li ◽  
Qi Fen Li ◽  
Lin Hui Zhao ◽  
Xin Zhao ◽  
...  

In this paper, the Unicom's medium-sized IDC room in a city of northern China is the research object for the study. Based on field research of the room refrigeration conditions, data center room air conditioning system is carried out to optimize and for energy conservation research. Through the analytic methods of energy saving-technology, the best energy saving solutions is explored.


2014 ◽  
Vol 602-605 ◽  
pp. 928-932
Author(s):  
Min Li ◽  
Yun Wang ◽  
Zheng Qian Feng ◽  
Wang Li

By studying the energy-saving technologies of air-conditioning system in data centers, we designed a intelligent air conditioning system, improved the cooling efficiency of air conditioning system through a reasonable set of hot and cold aisles, reduced the running time of HVAC by using the intelligent heat exchange system, an provided a reference for energy saving research of air conditioning system of data centers.


Energy ◽  
2020 ◽  
Vol 210 ◽  
pp. 118521 ◽  
Author(s):  
Zongwei Han ◽  
Qiang Ji ◽  
Haotian Wei ◽  
Da Xue ◽  
Xiaoqing Sun ◽  
...  

2014 ◽  
Vol 960-961 ◽  
pp. 625-630
Author(s):  
Qiao Yan Ma ◽  
Shu Xing Zhao ◽  
Long Huang ◽  
Cheng Deng

The air conditioning system did not run as the design conditions in most of the time. Therefore, how to rationally adjust air parameters under part-load conditions caused by changes in the outdoor environment is an important issue, which is crucial to people’s comfort and energy systems. This paper introduces the part-load rate α to distinguish among different load-part conditions. And by taking the typical conditioned space of underfloor air distribution (UFAD) system in perimeter zone of New Tianjin Library as the object and using Fluent for simulation analysis, we get the conclusion that there is a maximum limit of supply air temperature and a minimum limit of supply air velocity under summer part-load conditions. For each condition, there is a set of optimal air parameters to make the indoor personnel achieve the most comfortable condition. Finally, we acquire this set of optimal air parameters by simulating and analyzing.